6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140
8)2 to 10 stations: W = 47n + 15611 to 20 stations: W = 47n + 190
8)2 to 10 stations: W = 47n + 15611 to 20 stations: W = 47n + 190
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140
Enclosure: W (IP67), SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: 2 Stations, Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (1/4" One-touch Fitting)
Stations: 6 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: N (Name Plate), Option 2: S (Built-in Silencer, Direct Exhaust)
Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: N (Name Plate), Option 2: S (Built-in Silencer, Direct Exhaust)
Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: N [NPN (-)]
Stations: 5 Stations, Port Size: N7 (1/4" One-touch Fitting), Thread Type: N (NPT), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 2 (M12, 4 Inputs)
8)2 to 10 stations: W = 47n + 15611 to 20 stations: W = 47n + 190
Stations: 08 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: Q (Device Net), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM), I/O Unit Stations: 3 Stations, Option 1: D (w/DIN Rail, Rail Length Standard), DIN Rail Length: None, Option 2: NS (N+S)
Stations: 08 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: N (PROFIBUS DP), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM), I/O Unit Stations: None, Option 1: None, DIN Rail Length: None, Option 2: S (Built-in Silencer, Direct Exhaust)
Stations: 02 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: EB (EtherNet/IPâ„¢ IO-Link), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM), I/O Unit Stations: None, Option 1: D (w/DIN Rail, Rail Length Standard), DIN Rail Length: None, Option 2: N (w/Name Plate)
Enclosure: W (IP67), SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: None, Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: Internal Pilot, A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: W (IP67), SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: None, Valve Stations: 6 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: W (IP67), SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: 4 Stations, Valve Stations: 9 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: IP40, SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: None, Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: Internal Pilot, A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: IP40, SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: None, Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: W (IP67), SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: None, Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: W (IP67), SI Unit: N (for PROFIBUS DP), End Plate Type: 2 (Power Supply with M12 Connector, Max. Supplied Current 2 A), SI Unit Common: N (Negative Common), I/O Unit Stations: None, Valve Stations: 14 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assy: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (1/4" One-touch Fitting)