Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted
ARM 2500 05 A 02 G1 Made to Order Nil None With backflow function Regulator for manifold X216 Easily set up using the new knob. Also has a One-touch lock system. Accessory (Pressure gauge) Body size None (With plug) Nil G1 G2 2500 3000 Back side thread: G33-1001 Vertical side thread: GA33-1001 Pressure gauges are shipped together (but not assembled).
Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted
Thermo-chiller Single-phase 200 to 230 VAC Environmentally Resistant Type HRS-R Series How to Order 018 A R 20 HRS Air-cooled refrigeration Stainless steel panel specication (Option) Cooling capacity 018 Cooling capacity 1700/1900 W (50/60 Hz) 030 Cooling capacity 2500/2900 W (50/60 Hz) Environmentally resistant type R Environmentally resistant type Cooling method Option A Air-cooled refrigeration
How to Order Port Number e r KT10 R C 4P 4 1 0 0 Installation option Delivery pressure Code Installation Panel installation Delivery pressure Code 5 to 500 psig (0.034 to 3.4 MPa) 5 to 800 psig (0.034 to 5.5 MPa) 10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) 50 to 6000 psig (0.34 to 41.4 MPa) 100 to 10 psig (0.7 to 69 MPa) 1) No code
2000 2500 1500 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Supply pressure (MPa) 822 Electro-Pneumatic Regulator Series ITV1000/2000/3000 Series ITV305 Linearity Hysteresis Repeatability 1.0 1.0 0.9 1.0 Output deviation factor (%F.S.) 0.8 Output deviation factor (%F.S.)
room compatible Clean room compatible CAT.ES100-87 Series LEFB Series LEFS Series LEFS Series LEFB Stroke (mm) Size Stroke (mm) Max. work load (kg) Size Stroke (mm) Max. work load (kg) Size Stroke (mm) Max. work load (kg) Max. work load (kg) Size 16 25 32 25 32 40 25 32 40 16 25 32 40 1 5 14 20 45 60 5 15 25 Up to 1000 Up to 2000 Up to 2000 Up to 600 Up to 800 Up to 1000 Up to 2000 Up to 2500
Lead wire length 46 -SCSJ3000For single solenoid: Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm 46 -DCSJ3000For double solenoid : Common specifications 46 47 For positive common For negative common For junction common How to Order Indicate the part no. of the connector assembly for the manifold and solenoid valve.
Lead wire length (mm) Nil 600 1000 1500 2000 2500 3000 Blanking plate with output 10 15 20 25 30 Blanking plate with a connector for individually outputting electricity to drive a single valve or equipment that are not on the manifold base. Note 1) Electric current should be 0.5 A or less.
2000 2500 3000 l l Support spacing l1 (mm) Support spacing l1 (mm) Caution Note) A side support must be used to keep the spacing from exceeding the value inside the parentheses.
0.35 W) Nil VQZ2000/3000 Nil Standard A and B side of VQZ1000 single, double solenoid type A side of VQZ1000 3 position (0.9 W) B Note) High speed response type SY100-30-A Without lead wire: (with connector and 2 sockets only) 4 High pressure type (Metal seal type only) (0.9 W) K Note) 5 B side of VQZ1000 3 position Lead wire length Note) Option Nil 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500
442 491 491 OUT 25 10 82.4 124 165 206 247 288 330 371 412 412 IN 161 241 322 402 482 563 643 724 804 804 OUT 32 12 138 207 276 346 415 484 553 622 691 691 IN 252 378 504 630 756 882 1010 1130 1260 1260 OUT 40 16 212 318 424 530 636 742 848 954 1060 1060 IN 392 588 784 980 1180 1370 1570 1760 1960 1960 OUT 50 20 330 495 660 825 990 1160 1320 1490 1650 1650 IN 624 936 1250 1560 1870 2180 2500
Gray (2 pcs.) 1000 1500 2000 2500 3000 4 Red: +, Black:For DC How to Order Specify the connector assembly part number together with the part number for the plug connector's solenoid valve without connector. Note) The solenoid valve and the connector assembly are shipped separately.
response type (Applicable to VQZ200/300) (0.9 W) B Note) SY100-30-A Without lead wire: (with connector and 2 sockets only) p Coil voltage High pressure type (Applicable to Metal seal type, Poppet seal type) (0.9 W) p K Note) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Lead wire length Nil 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500
0.1 Hz 500 Immediately Tuning 2 Vibration Suppression 1 Frequency B Pn146 10 to 2500 0.1 Hz 700 Immediately Tuning Model Following Control Speed Feedforward Compensation Pn147 2 0 to 10 0.1% 1000 Immediately Tuning 2 2nd Model Following Control Gain Pn148 10 to 20 0.1/s 500 Immediately Tuning 2 2nd Model Following Control Gain Compensation Pn149 500 to 2000 0.1% 1000 Immediately Tuning
Range Setting Enabled Section Model Following Control Bias Pn143 2 0 to 10 0.1% 1000 Immediately Tuning (Forward Direction) Model Following Control Bias Pn144 2 0 to 10 0.1% 1000 Immediately Tuning (Reverse Direction) 2 Vibration Suppression 1 Frequency A Pn145 10 to 2500 0.1 Hz 500 Immediately Tuning 2 Vibration Suppression 1 Frequency B Pn146 10 to 2500 0.1 Hz 700 Immediately Tuning
(P2) () 3) 4) 5) 23 5 No.VEX-OMY0001 VEX3 3 / DC () 5 20N 1) 2) 1 ()ISO VG32 2 ISO VG32 ,(SDS) 6 No.VEX-OMY0001 VEX3 3 / () 30 ( ) , 1 VG32 2 ()ISO VG32 7 No.VEX-OMY0001 VEX3 VEX3 12,22,32,42 ,300mm DXT170-80-A1) 2) Lmm 2 300 6 600 1 (2 ) AC100V 10 1000 2 (2 ) AC200V 15 1500 3 (2 ) AC 20 2000 DC L 4 :+ :DC 25 2500 DXT170-71-1 30 3000 0.20.33mm ( 1.7mm) DC : M 3.23.7mm
(Red) (Black) Single solenoid SJ3000-46-S-l Double solenoid, 3 position type, 4 position type SJ3000-46-D-l (White) (Red) (Black) N C C N Lead wire length For single solenoid : SJ3000-46-SC-l (Red) (Black) Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm (White) (Red) For double solenoid For 3 position type : SJ3000-46-DC-l For 4 position type (Black)
Ambient temperature Applicable cylinder thread nominal size Allowable eccentricity U (mm) Applicable cylinder bore size (mm) Note 1) Maximum tension and compression N Air cylinder Hydraulic cylinder JS10-4-070 JS16-5-080 JS20-8-125 JS32-10-125 JS40-14-150 JS63-18-150 M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 0.5 0.5 0.5 0.5 0.75 1 10 10, 16 20 25, 32 40 50, 63 80 210 1100 2500
Specifications Body Size (in.) 1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 Maximum Rated Pressure (PSI) 5000 5000 5000 5000 4000 4000 4000 3000 Except the following port options in the noted size 03 (Male JIC 37) 3000 2000 05 (Male SAE O-Ring Boss) 2500 06 (Female JIC 37) 90 Housing Port 4000 3000 3000 2500 2000 06 (Female JIC 37) In-Line Housing Port 3000 2000 07 (Female NPSM) 4600 3000 2600 2100 1650