M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V, 12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC 24 V Yes 3-wire (NPN) 5 V, 12 V M9NAV*1 M9NA*1 M9NAV*1 M9NA*1 v v V v v IC circuit 3-wire (PNP) M9PAV*1 M9PA*1 M9PAV*1 M9PA*
Operating current of load > Leakage current (Input OFF signal of controller) V (mm/s) = Auto switch operating range (mm) Time load applied (ms) X 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied.
Confirm that the kinetic energy of the load does not exceed the allowable kinetic energy. 1 2 V 1000 E = W (-) 2 Collision speed V = 1.4 Va Ea = KEmax Workpiece mounting coefficient K: Fig. (3) Max. allowable kinetic energy Emax: Table (1) Kinetic energy (E) Allowable kinetic energy (Ea) ) Correction factor (Reference values) Load Factor 3 Load factor of load mass 3-1 Load factor of the
The maximum piston speed is: Auto switch operating range (mm) Load applied time (ms) V(mm/s)= 1000 2. Take precautions when multiple rotary tables are used close together. When multiple auto switch rotary tables are used in close proximity, magnetic field interference may cause the auto switches to malfunction. Maintain a minimum cylinder separation of 40 mm.
Lead wire length (m) Rail mounting 12 to 63 32 to 63 Load voltage Direct mounting Indicator light Applicable load Pre-wire Type Special function Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC connector Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A76H A96V A96 Grommet Reed switch Solid state switch A93 M9N M9P M9B F9NW
When bank 2 is selected Decimal no. 1 2 3 4 5 6 7 8 9 0 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 Output terminal 6 7 8 9 10 Preset no.
D-M9B SMC D-M9B SMC For D-P4DW D-M9V D-M9WV D-A9V 28 Note) Allow 35 mm or more space at the cylinder head side to secure the minimum bending radius of the auto switch lead wire. 544 Auto Switch Mounting C(L)KQG32 Series Auto Switch Mounting Bracket Part No.
Applicable load 0.5 (Nil) 3 (L) 5 (Z) Auto switch model Special function Type Load voltage AC DC Wiring (Output) Electrical entry Pre-wire connector In-line Perpendicular Reed switch 3-wire (NPN equivalent) IC circuit A96 A96V 5 V Grommet Yes 2-wire 24 V A93 12 V 100 V Relay, PLC A93V 3-wire (NPN) 3-wire (PNP) M9N M9NV IC circuit 5 V, 12 V M9PV M9P Solid state switch 12 V 2-wire M9B
Series Variations Series Bore size (mm) Standard stroke (mm) Cushion 5 10 15 20 25 30 35 40 45 50 75 100 12, 16 20, 25 Rubber bumper CQM 32, 40 50 7-5-1 2 Compact Cylinder: Guide Rod Type Double Acting, Single Rod Series CQM 12, 16, 20, 25, 32, 40, 50 How to Order Without auto switch B 20 10 CQM M9B S B 20 10 CDQM With auto switch With auto switch Courtesy of Steven Engineering, Inc.-230
The maximum detectable piston speed is: Auto switch operating range (mm) Time load applied(ms) V(mm/s)= 1000 Keep wiring as short as possible.
The maximum detectable piston speed is: Warning Warning Caution Warning Caution Auto switch operating range (mm) Time load applied(ms) V(mm/s)= 1000 8 -
Keep wiring as short as possible.
The maximum piston speed is: Auto switch operating range (mm) Load applied time (ms) V(mm/s)= 1000 2. Take precautions when multiple rotary tables are used close together. When multiple auto switch rotary tables are used in close proximity, magnetic field interference may cause the auto switches to malfunction. Maintain a minimum cylinder separation of 40 mm.
(Page 9) 6 Bushing (bearing) 1000 Lateral load applied to rod end {N} (fR)[N] 100 100 80 63 50 10 40 32 1 1900 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 end 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Center Q1 = 0.019 + 0.040 + 0.019 + 0.040 = 0.118 L(ANR) End Center End Center Air consumed in the tubing is calculated using formula (2), as shown below. 0.5 0.1 Q2 = 12.6 x 1000 x x 10-6 = 0.063 L(ANR) An entire stroke includes two rotations from end to center where the air is consumed. Thus, the total air consumption Q of the rotary table and tubing is obtained as shown below.
Load voltage Auto switch model Lead wire length (m) Indicator light Wiring (Output) Pre-wired connector Applicable load DC Electrical entry Type Special function 0.5 (Nil) 3 (L) 1 (M) 5 (Z) AC M9N M9P M9B M9NW M9PW M9BW M9NA1 M9PA1 M9BA1 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire Reed auto switch Solid state auto switch IC 5 V, 12 V
Load voltage Pre-wired connector Applicable load Auto switch model Lead wire length (m) Tie-rod mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) 1 (M) G39 K39 Indicator light Wiring (Output) Electrical entry Type Special function DC AC M9N M9P M9B J51 M9NW M9PW M9BW M9NA M9PA M9BA F59F 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 24 V Grommet 12 V 2-wire 100 V, 200 V Solid state switch
RS2H50, 63, 80 1.0 0.9 RS2H63 RS2H50 0.8 RS2H80 Operating pressure P [MPa] 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1000 2000 3000 4000 0 5000 Lateral load F [N] Even after the impact of the carried object is absorbed, lateral load acts on the stopper cylinder due to the friction generated between the conveyor and the carried object.
Load voltage Auto switch model Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (output) Special function Tie-rod mount Type Electrical entry Applicable load Pre-wired 40 to 100 32 40 to 100 32 Band mount AC DC None connector G59 G5P K59 M9N 3-wire (NPN) F59 5 V, 12 V IC circuit M9P Grommet 3-wire (PNP) 24 V F5P M9B 12 V 2-wire Reed auto switch Solid state auto
voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load Applicable bore size Indicator light Type Special function Electrical entry Wiring (Output) DC AC 20 to 63 80, 100 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line In-line M9NV M9N V V V IC circuit 3-wire (NPN) G59 V V 5 V, 12 V 3-wire (PNP) M9PV M9P V V V G5P V V Grommet 2-wire 12 V M9BV M9B