Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch mounting screw (M3 x 0.5 x 10l
M3 x 0.5 x 6L M3 x 0.5 x 8L M3 x 0.5 x 10L BMU-1-025 BQ-1 BQ-2 1 1 1 Note 3) Auto switch mounting brackets and auto switches are packed together at cylinder shipment. Auto switch mounting screws 1 D-A7/A8 D-F7/J7 BBA2 Auto switch mounting nuts (square nut) 2 M3 x 0.5 1 BQ-1 Auto switch mounting nuts (convex) 3 M3 x 0.5 1 BQ-2 Spacers (black resin) for BQ-2 are not included.
BQ5-032 BQ6-032S Hexagon socket head cap screw (M 2.5 x 6L) Auto switch mounting bracket (nut) Weight: 5 g Auto switch fixing screw (M2.5 x 10L) Auto switch mounting screw (M3 x 8L) Auto switch spacer Auto switch mounting nut Weight: 3.5 g Auto switch mounting bracket fitting parts lineup/Weight When requesting the enclosure of the auto switch mounting brackets (2 pcs.) with the cylinder
@2 @3 @4 @5 @6 @7 @8 @9 #0 #1 #2 #3 MVGQ Chromated CC Hard chromium electroplated Oil-impregnated sintered alloy Rolled steel Steel wire Aluminum alloy Aluminum alloy Alloy steel Carbon tool steel Aluminum alloy Stainless steel Aluminum alloy Stainless steel Urethane Urethane RB Nickel plated Zinc chromated Chromated Chromated J DBlack zinc chromated Nickel plated Metallic painted M3 x 10l
Piping 4-M3 x 0.5 thread depth 4.5 16 12 + Stroke 3.5 8 7.5 2-M5 x 0.8 thread depth 4 (Piping port) 28.5 8 Stroke 15 56 + Stroke 8 3.5 13 1 44.5 + Stroke M5 x 0.8 x 4l (Hexagon socket head set screw) 4 16 8 + Stroke M8 x 1.25 x 7.5l (Bolt holder) 1 40 33 0.2 33 0.2 20 42 8 8 3.4 through 6.5 counterbore with depth 5.5 (Opposite side: Same) 2-M3 x 0.5 through 6.5 2-M4 x 0.7 through M3 x 0.5 x 10l
(kPa) Vacuum pressure (kPa) Vacuum pressure -60 30 -60 -60 30 -60 Air consumption Air consumption -40 20 -40 -40 20 -40 Suction flow rate Suction flow rate -20 10 -20 -20 10 -20 0 0 5 10 15 20 25 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 0 10 20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 Supply pressure (MPa) Suction flow rate (l/min(ANR)) Supply pressure (MPa) Suction flow rate (l/min(ANR)) ZY -10S Y3 X3 ZY -10L
M6 x 10l (Hex. bolt) 2 pcs. BM58 Bracket set Ball valve/Rc 1/2 1 pc. Barrel nipple/R 1/2 2 pcs. Elbow/Rc 1/2 1 pc. Ball valve piping set ADH-C400 Note) The accessories (Option) are shipped unassembled, but packed in the same container.
D-F7 , J79 D-F V D-J79C D-F7 W, J79W D-F7 WV D-F7BAL D-F7 F, D-F7NTL 32, 40 50, 63 80, 100 D-A7 , A80 D-A73C, A80C D-A7 H, A80H D-A79W Switch mounting screw (M3 X 0.5 X 10l) BQ-2 Switch interface Switch mounting nut 2.3-116 Compact Cylinder/Anti-lateral Load Series CQ2 32, 40, 50, 63, 80, 100 How to Order Standard D CQ2 B S 32 30 C CDQ2 With auto switch B S 32 30 D C A73 S Number of
M6 x 10l (Hex. bolt) 2 pcs. BM58 Bracket set Ball valve/Rc 1/2 1 pc. Barrel nipple/R 1/2 2 pcs. Elbow/Rc 1/2 1 pc. Ball valve piping set ADH-C400 Note) The accessories (Option) are shipped unassembled, but packed in the same container.
M6 x 10l (Hex. bolt) 2 pcs. BM58 Bracket set Ball valve/Rc 1/2 1 pc. Barrel nipple/R 1/2 2 pcs. Elbow/Rc 1/2 1 pc. Ball valve piping set ADH-C400 Note) The accessories (Option) are shipped unassembled, but packed in the same container.
(Including nut, screw) How to Mount and Move the Auto Switch Applicable bore size (mm) 25 BMY2-025 BMY1-025 Cylinder series M2.5 x 12l M2.5 x 10l CE2 32 BMY2-025 BMY1-025 40 BMY2-025 BMY1-025 ML1 ML2B Set screw
Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch mounting screw (M3 x 0.5 x 10l
Note Applicable auto switch (N) Bore size (mm) 12 16 20 32 40, 50 Extended Compressed D-A7/A8 D-A7H D-A73C/A80C D-F7 D-F7V, D-F7NT D-F7W/J79W D-F7WV D-F79F D-J79/J79C D-F7BAL/F7BAVL Switch mounting screw (M3 x 0.5 x 8l) Square nut 9.6 3.9 16 20 BQ-1 14.9 4.9 14.9 3.4 Switch mounting nut Switch mounting screw (M3 x 0.5 x 10l) Switch spacer 18.6 8.8 32 40 50 27.5 13.7 BQ-2 Applicable
(Including nut, screw) How to Mount and Move the Auto Switch Applicable bore size (mm) 25 BMY2-025 BMY1-025 Cylinder series M2.5 x 12l M2.5 x 10l NCM 32 BMY2-025 BMY1-025 40 BMY2-025 BMY1-025 ML1 NCA Set screw
(Including nut, screw) How to Mount and Move the Auto Switch Applicable bore size (mm) 25 BMY2-025 BMY1-025 Cylinder series M2.5 x 12l M2.5 x 10l 32 BMY2-025 BMY1-025 40 BMY2-025 BMY1-025 ML1 Set screw
(Including nut, screw) How to Mount and Move the Auto Switch Applicable bore size (mm) 25 BMY2-025 BMY1-025 Cylinder series M2.5 x 12l M2.5 x 10l 32 BMY2-025 BMY1-025 40 BMY2-025 BMY1-025 ML1 Set screw
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 40 33 0.2 33 0.2 20 42 8 8 3.4 through 6.5 counterbore with depth 5.5 (Opposite side: Same) 2-M3 x 0.5 through 6.5 2-M4 x 0.7 through M3 x 0.5 x 10l (Hexagon socket head cap screw) M4 x 0.7 x 14.5l (Hexagon head bolt) M4 x 0.7 (Hexagon nut) (16) (8
(Including nut, screw) How to Mount and Move the Auto Switch Applicable bore size (mm) 25 BMY2-025 BMY1-025 Cylinder series M2.5 x 12l M2.5 x 10l D32 BMY2-025 BMY1-025 40 BMY2-025 BMY1-025 ML1 -X Set screw
Note Auto switch part no. 8.34 8.34 6.86 When extended Spring force (N) 20.50 20.50 15.98 When retracted 205 to 60C Operating temperature range Switch mounting screw M2.5 x 10l D-E73A/ 76A/80A BMY1 -025 Data Switch mounting nut Weight (kg) D-M5N/ M5P/M5B D-M5NW/ M5PW/ M5BW D-M5NTL/ M5PTL 25 32 40 Side support weight (per set) Stroke adjustment unit weight (per unit) Basic weight Additional
In order to hold the locked state, be sure to follow the steps below after confirming safety. 1) Remove the dust cover (1). 2) Supply air pressure of 0.2 MPa or more to the unlocking port (2) shown below and unlock. 3) Screw the attached hexagon socket head cap bolt (3) (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), into the lock ring to hold the unlocked condition. 2.