Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 300mm, CE Compliant: CE Compliant
How to wire DIN terminal 1. Disassembly 1) After loosening the screw (1), then if the housing (4) is pulled in the direction of the screw (1), the connector will be removed from the body of equipment (solenoid, etc.). Exploded view 2) Pull out the screw (1), then remove the gasket (2) . 3) On the bottom part of the terminal block (3), theres a cut-off part (indication of an arrow) (3a).
Mounting Warning 1. Operation Manual (this document) In the case of diodes, the residual voltage is approximately 1 V. 4.
Connecting Female Thread: G Approx. spanner tightening angle after tightened by hand deg Standard torque (Nm) Nominal size of uni thread 1 8 1 4 3 8 1 2 30 to 45 15 to 30 15 to 30 15 to 30 3 to 4 4 to 5 8 to 9 14 to 15 2. Gasket can be recycled 6 to 10 times. It can be replaced easily when it has sustained damage.
Clean Exhaust Filter SFE Series RoHS How to Order SFE 11 Size/Port size Male thread type Plug-in type Symbol Port size Max. ow capacity L/min (ANR) 11 M5 x 0.8 3 42 R1/8 65 52 R1/8 130 53 R1/4 130 73 R1/4 200 Symbol Port size Max. ow capacity L/min (ANR) 3A 4 30 4B 6 65 5C 8 130 7D 10 200 Male thread type One-touch tting type Symbol Applicable tubing O.D.
Replace the adsorbent according to color of the indicator. 1 4 1 2 1 2 3 4 520 615 850 961 45 45 75 75 9 9 9 9 120 120 170 170 95 95 95 95 59.5 59.5 88 88 128.5 128.5 243.5 243.5 59.5 59.5 66.5 66.5 134.5 134.5 183 183 222 222 302 302 Dew point temperature (Atmospheric pressure) 30C or less 18C 10C 5C Color of indicator ID300 ID400 ID600 Dark blue Light blue Light pink air, the capillary
Replace the adsorbent according to color of the indicator. 1 4 1 2 1 2 3 4 120 120 170 170 45 45 75 75 520 615 850 961 128.5 128.5 243.5 243.5 59.5 59.5 66.5 66.5 95 95 95 95 134.5 134.5 183 183 222 222 302 302 59.5 59.5 88 88 9 9 9 9 Dew point temperature (Atmospheric pressure) 30C or less 18C 10C 5C Color of indicator ID300 ID400 ID600 Dark blue Light blue Light pink air, the capillary
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 1000mm, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 1000mm, CE Compliant: CE Compliant
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®)
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Tube Connection, Plumbing Thread Nominal: -, Tube Diameter: φ2.8, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Body
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 6 (600mm), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: KO (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: KOZ (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: K (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: KZ (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant