) Note 1) Max. stroke with switch (mm) Standard stroke (mm) Max. stroke without switch (mm) Bore size (mm) X168 Helical insert thread specifications X322 Outside of cylinder tube with hard chrome plating 50, 100, 150, 200, 250, 300 350, 400, 450, 500 XC57 With floating joint 15 750 1000 20 1000 1500 Minimum Operating Pressure 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1200
1400 1600 1800 2000 MY3A/3B 3000 16, 25, 40, 63 CAT.S20-153 English cat.no.ES20-153 Mechanical Joint Rodless Cylinder/Compact and Low Profile Series MY2H/HT Series MY2H/HT Standard stroke (mm) Bore (mm) Model Guide 50 100 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1200 MY2C 16 Cam follower guide High precision guide Single axis MY2H 25 High precision guide Double axes MY2HT
Minimum Bending Radius (mm) 1/8 9.4 5/32 12.7 3/16 19.1 1/4 25.4 5/16 31.8 3/8 38.1 1/2 50.8 5/8 63.5 3/4 76.2 Minimum Burst Pressure (psi) at 24C (75F) 1000 1200 1200 1200 1000 1000 950 900 800 Material Nylon 12 (Polyamide) *Note: Recommended fluid and ambient temperature range provides best performance and longest life.
to 100 psig (0.014 to 0.7 MPa) AK1315 5 to 150 psig (0.034 to 1.0 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Leak rate Connections Supply pressure effect Installation Internal volume Mass Select compatible materials of construction for the gas Vacuum to 300 psig (2.1 MPa) 450 psig (3.1 MPa) 1200
Caution Theoretical Cylinder Thrust 6, 10 15, 20, 25, 32, 40 50, 63 CY3B CY3R CY3B CY3R CY1S 63 63 1200 40 40 1100 3000 100 90 80 70 60 50 40 30 20 10 Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) H CY1L Bore size 10 Bore size 2500 1000 900 800 700 10 50 50 H 32 32 2000 CY1H 1500 600 25 25 500 400 300 200 100 CY1F 1000
) external metal parts Available with two types of seal material (NBR or FKM) to suit application is standard Special scraper to prevent liquid from entering cylinder Uses grease that meets FDA standards Series CG5 How to Order Auto Switch Standard With Auto Switch (Magnetic Piston) Option X6011 CG NFPA Nil D Mounting X D E C F G L S P Stroke (mm) Bore 40 50 63 80 100 Max Stroke 800 1200
(mm) Maximum stroke Cushion Piping directions Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated piping on right 28 34 46 46 63 198 225 205 294 260 DBuilt-in shock absorber 39.5 CY1F 15 750 Concentrated piping on left -X 25 1200
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range Bore
1 3/4 5 1/8 NI-1200 2 1/4 4 2 1/2 1 3/4 2 1 1/2 -12 NCA1-1400 2 5 1/8 NI-1400 3 5 2 1/2 2 2 1/2 1 7/8 -12 NCA1-1401 2.5 6.19 NI-1401 3 1/2 5 13/16 3 2 1/2 2 13/16 2 1/4-12 NCA1-1402 3 6.25 Note) Retainer Rings are included NI-1402 3 1/2 6 1/8 3 3 3 1/4 2 1/2-12 42 Medium Duty Air Cylinder Series NCA1 How to Order Auto Switches Wire Lead Type Connector Type D D PC Lead wire length 0.5 (m)
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
(page 77 to 78) Y S16 0x04B0 3 R/W (1200) P1H (Upper limit of the OUT1 window comparator) Setting of OUT1 upper limit of window comparator. (page 77 to 78) Y S16 0x0960 0x04C4 (1220) 0x04C5 (1221) 0x04C6 (1222) 0x04C7 (1223) 4 R/W (2400) WH1 (Setting of OUT1 window comparator hysteresis) Setting of OUT1 window comparator hysteresis.
Setting of OUT1 output set value (Lower limit of window comparator) S16 1200 Y Setting range -200 to 4200 3 R/W 1220 0x04C4 P1H(n1H) (Upper limit of window comparator) Setting of OUT1 output set value (Upper limit of window comparator) S16 2400 Y Setting range -200 to 4200 4 R/W WH1 (Window comparator hysteresis) Setting of OUT1 hysteresis (Window comparator) S16 400 Y Setting range 0 to
Setting of OUT1 output set value (Lower limit of window comparator) S16 1200 Y Setting range -200 to 4200 3 R/W 1220 0x04C4 P1H(n1H) (Upper limit of window comparator) Setting of OUT1 output set value (Upper limit of window comparator) S16 2400 Y Setting range -200 to 4200 4 R/W WH1 (Window comparator hysteresis) Setting of OUT1 hysteresis (Window comparator) S16 400 Y Setting range 0 to
(Displays 0 when the (Displays 0 when the (Displays 0 when the value is below 270 L/min) value is below 540 L/min) value is below 1080 L/min) 300 to 3150 L/min 600 to 6300 L/min 1200 to 12600 L/min 10.0 0 to 10%F.S.
(Page 47) P1L (n1L) (Lower limit of window comparator) Setting of OUT1 output set value (Lower limit of window comparator) 3 R/W S16 1200 Y 1220 0x04C4 Setting range Refer to "Settable range list". (Page 47) P1H (n1H) (Upper limit of window comparator) Setting of OUT1 output set value (Upper limit of window comparator) 4 R/W S16 2400 Y Setting range Refer to "Settable range list".
1: 1.0 sec 2: 2.0 sec 3: 5.0 sec 4: 10.0 sec 5: 15.0 sec 6: 20.0 sec 7: 30.0 sec 1030 0x0406 0 R/W FiL (Digital filter) U8 0 Y Setting of digital filter tP_1(tn_1) (Selection of temp. output set value) Setting range 0xFF9C to 0x044C (-100 to 1100) Setting of OUT1 output set value (Temp. hysteresis) 1040 0x0410 0 R/W S16 500 Y OUT1 setting (temperature) Setting range 0x0 to 0x04B0 (0 to 1200
1: 1.0 sec 2: 2.0 sec 3: 5.0 sec 4: 10.0 sec 5: 15.0 sec 6: 20.0 sec 7: 30.0 sec 1030 0x0406 0 R/W FiL (Digital filter) U8 0 Y Setting of digital filter tP_1(tn_1) (Selection of temp. output set value) Setting range 0xFF9C to 0x044C (-100 to 1100) Setting of OUT1 output set value (Temp. hysteresis) 1040 0x0410 0 R/W S16 500 Y OUT1 setting (temperature) Setting range 0x0 to 0x04B0 (0 to 1200
Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.