A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo
ML2B25 0.3 0.4 0.5 ML2B32 ML2B32 ML2B32 ML2B32 1 0.2 0.3 0.4 0.5 ML2B25 ML2B25 ML2B25 ML2B25 0.2 0.5 0.4 0.3 0.1 0.1 0.2 0.05 0.05 0.1 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Dynamic Moment Moment generated by impact load at stroke end Reference formula [Dynamic moment at impact
Zinc chromated Tie rod Carbon steel 4 19 Rod seal NBR 1 20 Stroke (In inches and hundredths) Bore 500 600 800 Gland seal NBR 1 21 22 Cushion seal Urethane 2 Cylinder tube gasket NBR 2 23 NCA 500 RG Bore 500 600 800 Special options Nil XB5 XC35 XB5C35 Standard Oversized rod Coil scraper Oversized W/ Coil scraper NC A 500 26A 0400 D NCA 500 11 0400 B Special options Nil XB5 XB6 XB7 XB5B6 XB5B7
Bore size Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
Suitable for static neutralization at a long distance (max. 500 mm).
3 Port Air Operated Valve VPA300/500/700 Series RoHS SYA SYJA VZA VFA VFRA VPA4 SYJA VZA VTA VGA VPA VPA VPA3 1555 VPA300/500/700 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm3/(sbar)] Type of actuation Port size Voltage Light/surge voltage suppressor Manual override Electrical entry VPA300 N.C. 2(A) 1/8 1/4 4.2 (P)1 3(R) VPA500
P24417154 SMC THERMO-CON AT SEL RET 19.7 in (500 mm) or more 19.7 in (500 mm) or more Note) The space must be 19.7 in (500 mm) or more. Be sure that the ambient temperature is within the specification range. 142 Series HEC-A Specific Product Precautions 2 Be sure to read this before handling.
ML2B + CEU2 START Stop signal Stop position Piston speed Stopping accuracy 100 to 500 mm/s 0.5 mm Idle running distance Braking distance Stop distance 2. ML2B + PLC (Overrun) (Run) Piston speed (mm/s) 100 0.5 300 1.0 500 2.0 800 3.0 1000 4.0 Stopping accuracy (mm) The graph below shows the relation between piston speed and overrun.
ML2B + CEU2 START Stop signal Stop position Piston speed Stopping accuracy 100 to 500 mm/s 0.5 mm Idle running distance Braking distance Stop distance 2. ML2B + PLC (Overrun) (Run) Piston speed (mm/s) 100 0.5 300 1.0 500 2.0 800 3.0 1000 4.0 Stopping accuracy (mm) The graph below shows the relation between piston speed and overrun.
ML2B + CEU2 START Stop signal Stop position Piston speed Stopping accuracy 100 to 500 mm/s 0.5 mm Idle running distance Braking distance Stop distance 2. ML2B + PLC (Overrun) (Run) Piston speed (mm/s) 100 0.5 300 1.0 500 2.0 800 3.0 1000 4.0 Stopping accuracy (mm) The graph below shows the relation between piston speed and overrun.
MY2C16 MY2H16 Horizontal impact: P = 0.5 MPa Horizontal impact: P = 0.5 MPa 2000 2000 1500 1500 H unit Impact speed mm/s Impact speed mm/s 1000 1000 L unit 500 400 500 L unit 400 300 300 Air cushion Air cushion 200 200 1000.5 1 2 3 4 5 100 10 30 20 0.5 1 2 3 4 5 10 20 30 m2 max. m1 max. m3 max. m1 max. m2, m3 max.
400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Select the load mass from within the range of limits shown in the graphs.
Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.
1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s MY2C MY2 H/HT Maximum Load Mass Select the load mass from within the range of limits shown in the graphs.
How to Order NC D A1 B 500 04 00 XB5 Built in magnet Bore size Option Nil 500 5" None Nil No option D Auto switch capable (magnetic option) 600 6" XB5 Oversized rod 800 8" XB6 High temperature Mounting style XB7 Low temperature XC6 Stainless steel piston rod B Basic style MX0 Standard stroke Inches BA Tie rod extended both ends MX1 Notes: BB Tie rod extended head end MX2 1.
Operating Conditions Mounting Orientation Cylinder MY2H40G-500 Average operating speed a 300 mm/s Mounting orientation Wall mounting 1. Horizontal mounting 2. Wall mounting z y P. 8-13-5 Wb: MGGLB25-200 (4.35 kg) x y x z Wa: Connection plate t =10 (880 g) MY2H40G-500 3. Ceiling mounting P. 8-13-5 4.
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).