SMC Corporation of America
Elite Part Number Search
Search Results "LEFG40-S-650"

Example) For REAL25-650 (1) Maximum load mass = 20 kg (2) Load mass for 650 st = 13.6 kg 13.6 (3) s = = 0.68 is the result. 20 1.

VS Surge voltage suppressor Light/Surge voltage suppressor Surge voltage suppressor Light/Surge voltage suppressor Varistor Coil VFN S Varistor Varistor Neon bulb Coil Coil Coil Coil Lead wire color Polarity Red Black + AC EZ, TZ, DZ, YZ (100 VAC or more) DIN terminal or terminal With DIN terminal block With terminal block Z EZ, TZ, DZ, YZ (24 VAC or less) Ground Red S Black Piping Neon

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT VP VG VP S070 VQ VKF VQZ VZ VS VFN Coil temperature rises: 1C (With power saving circuit) Sonic conductance C: 0.037 (Standard)/C: 0.076 (Large flow capacity) Series Flow characteristics C[dm3/(s bar)] b Cv Standard Large flow capacity V14 V14A 0.037

Z S L, Z S Note ) PAX 1 1 4 1 2 PB AC Ordering example (Example) Series VXR21, Rc 3/4, 24 VDC, Conduit terminal (Part no.)

VS4040-S-03 VS4040-S-04 DXT131-15P-06 DXT131-15P-10 DXT132-15-2P-12 DXT132-15-2P-14 XT021-9 DXT132-16 M6 x 25 with washer M8 x 35 3 8 1 2 3 4 VP450 Aluminum alloy Sub-plate !0 1 1 VP470 1 1 4 1 2 VP450 VP470 VP450 VP470 in part numbers are the same symbol for the thread type in How to Order. Gasket !1 Hexagon socket head screw VT3112-00G !2 Thread for mounting valve.

01(R) Note 1) Option Note 2) When two or more symbols are specified, indicate them alphabetically. (2) 01 [Rc 1/8] 02 [Rc 1/4] 02 [Rc 1/4] 03 [Rc 3/8] VQZ200 VQZ200-S(2) VQZ300 VQZ300-S(2) Note) Symbol R indicates an external pilot.

O S Open Close 4. It is not possible to replace the auto-drain alone. The entire bowl assembly must be replaced (except sizes 75B and 650). Auto-drains of sizes 2B to 37B and 150 to 650 cannot be replaced alone since they cannot be assembled without dedicated assembly tools. The entire bowl assembly must be replaced. (Refer to How to Order Bowl Assembly on page 14-20-59.) 5.

S A93 MGT MY Table unit/ Number of auto switches CY Table unit/ Auto switch S 1 pc.

Port size S L 2150 06 Rc 3/4 Rc 1 Rc 1 1 2 2160 10 2280 14 Z Refer to the table (1) given below for availability.

Note 3) 200 to 240VAC is "S" specification standard. Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.

How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are

Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Functions Error function Display calibration function Take the following corrective solutions when error occurs.

OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.

S Z Nil 14 1 2 1 20 2 Indicator light is not available for grommet type.

Rc NPT G Function 0 1 2 3 position closed center 3 position exhaust center 2 position Flow Characteristics VH200 VH300 VH400 Effective area S = 55 mm2 Effective area S = 7.5 mm2 Effective area S = 20 mm2 Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0 Valve

None With light/Surge voltage suppressor (Except type G) With surge voltage suppressor (Type G only) VX2 Option Option S VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Accessory Function plate (D seal, with thread): DXT060-32-4A Electrical entry G E T D VX3

mm or more. 12 3 500 12 3 450 10 2 400 10 2 350 8 1 300 8 1 250 6 0 200 6 0 150 6 0 100 Stroke F E Stroke F E 20 7 900 20 7 850 18 6 800 18 6 750 16 5 700 16 5 650 14 4 600 14 4 550 22 8 950 22 8 1000 13 Electric Actuator/Maintenance Guide 1 Be sure to read before handling.