Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

CDRB2BWU15-S M5 x 0.8 M5 x 0.8 M3 x 0.5 18.5 29 25 M3 x 0.5 depth 5 CDRB2BWU15-D M3 x 0.5 DCDRB2BWU20-S M5 x 0.8 M5 x 0.8 25 36 25 M4 x 0.7 depth 7 CDRB2BWU20-D M5 x 0.8 CDRB2BWU30-S M5 x 0.8 M5 x 0.8 25 43 25 M5 x 0.8 depth 10 CDRB2BWU30-D M5 x 0.8 Note) For rotary actuators with angle adjuster and auto switch unit, connection ports are side ports only.

L2 Kinetic Energy 2 1 420 2 E = 0.2 () = 0.018 2 1000 V = 1.4 x 300 = 420 1 420 2 E = 0.2 () = 0.018 2 1000 V = 1.4 x 300 = 420 1 V 2 E = W () 2 1000 1 V 2 E = W () 2 1000 Find the kinetic energy E (J) of the load.

48 V, 100 V, 110 V, 120 V, 200 V, 220 V, 230 V, 240 V DC 12 V, 24 V Allowable voltage fluctuation 10% of the rated voltage Allowable leakage voltage AC 5% or less of the rated voltage DC 2% or less of the rated voltage Apparent power*4, *5 AC 4.5 VA 8 VA 9.5 VA Power consumption*4 DC 4 W 6 W 8 W Temperature rise*6 AC/DC 70/65C Glossary of Terms Coil specifications *1 Leakage: The value at

VQC VQZ SQ VFS VFR +24 V +24 V VQ7 Power supply for output Power supply for output 0 V 0 V Power supply for the input and for the control unit of the Gateway Power supply for the input and for the control unit of the Gateway +24 V 24 V Caution 1. Take measures to avoid applying repeated bending force or pulling force to the cable.

V V V V V KQ2H06-M5G1 V KQ2H06-01GS1 V V KQ2H08-01GS V V Male connector Stainless steel One-touch fittings KQ2S04-M5G1 V V V V V V V KQ2S06-M5G1 V V V KQ2S06-01GS1 V V KQ2S08-01GS V V Hexagon socket head male connector Male connector KQG2H04-M5 V V V KQG2H06-01S V V KQG2H08-01S V V One-touch fittings/ Stainless steel 316 KQG2S04-M5 V v V V V V V KQG2S06

Model to be used Type of cushion Workpiece mounting position Mounting orientation Average speed Va (mm/s) Load mass W (kg): Fig. (1) Overhang Ln (mm): Fig. (2) L1 L2 + A5 L3 2 2 E = W () 1 2 V 1000 Find the kinetic energy E (J) of the load. 2 E = 1 () = 0.088 1 2 420 1000 Collision speed V = 1.4 Va ) Correction factor (Reference values) V = 1.4 x 300 = 420 Find the allowable kinetic

, D-A93 (V), D-A96 (V) Stroke (mm) Model 300 250 275 50 75 100 200 225 25 125 150 175 A 31.5 27.5 27.5 52.5 27.5 27.5 B 100.5 125.5 150.5 79.5 175.5 200.5 B A MXW8 W 11.5 7.5 7.5 32.5 7.5 7.5 V 120.5 145.5 170.5 99.5 195.5 220.5 A 51 31 31 31 31 B 104 124 149 174 199 MXW12 W 31 11 11 11 11 V 124 144 169 194 219 W V A 34.5 34.5 59.5 34.5 34.5 34.5 B 235.5 260.5 135.5 160.5 185.5 210.5 MXW16

(Inch) 1 /4 3/8 1/8 5/32 1/4 5/16 M5 Pressure Specifications VP4 V V V VQZ1000 V VQZ2000, 3000 Series A, B port 2 position single 2 position double 3 position V V V VQZ2000 Metal seal only VQZ3000, 3 position 0.15 to 0.7MPa 0.1 to 0.7MPa V V V V VQZ3000 External pilot pressure range VQ Note) Millimeter sizes of One-touch fittings (Cl) are also available.

Flexible cable is used for the D-M9(V), DM9W(V), D-M9A(V), D-M9A(V) as standard.

www.stevenengineering.com I 5.23 AIR PREPARATION SERIES NAP100 PRESSURE CONTROL VALVE The (N)AP Series pressure relief regulator is an adjustable re l i e f v a l v e w i t h a c o n t ro l r a n g e o f 1 8 ~ 1 0 0 P S I .

V IC circuit 5 V, 12 V 40 to 160 40 to 100 Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) Terminal conduit 5 V, 12 V 40 to 100 40 to 160 Relay, PLC 12 V 2-wire 3-wire (NPN) 5 V 12 V IC circuit Diagnostic indication (2-color indication) 24 V 3-wire (PNP) 40 to 100 12 V Grommet 2-wire Water resistant (2-color indication) 40 to 160 With diagnostic output (2-color indication

47 27 27 B 128 203 108 153 178 MXW12 W 15 15 35 15 15 V 140 215 120 165 190 A 55.5 30.5 30.5 30.5 30.5 30.5 B 140 215 240 165 265 190 MXW16 W 43.5 18.5 18.5 18.5 18.5 18.5 V 152 227 252 177 277 202 A 39.5 39.5 64.5 39.5 39.5 39.5 39.5 B 222.5 247.5 172.5 272.5 197.5 297.5 322.5 MXW20 W 27.5 27.5 52.5 27.5 27.5 27.5 27.5 V 234.5 259.5 184.5 284.5 209.5 309.5

W W W Dynamic moment Moment generated by the load equivalent to the impact at the stroke end Guide central axis We = WV V = 1.4Va Average load coefficient Pitch moment Me1 = 1/3WeL Yaw moment Me3 = 1/3We (LA) (mm) We: Load equivalent to impact [N] : Bumper coefficient With adjustment bolt (standard) =4/100 With shock absorber =1/100 W : Load weight [kg] V : Impact speed [mm/s] Va: Average

(mm) Fitting type Fitting model Cylinder model size Connection thread Cylinder model size Connection thread Male connector Male elbow Male connector Male connector Male elbow 4 KJH23-M5 KJL23-M5 KJS23-M5 KQ2H23-M5 KQ2L23-M5 KJL04-M5 KQ2L04-M5 KQ2S04-M5 KQ2L06-M5 KJS23-M5 KQ2H23-M5 KQ2L23-M5 KQ2H04-M5 KQ2L04-M5 KQ2S04-M5 KQ2H06-M5 KQ2L06-M5 KQ2S06-M5 KQ2H23-01S KQ2L23-01S KJH04-01S KJS04-01S

valve M5 thread depth 0.158 PV 0.04 0.287 Silencer cover (Detachable) vacuum (V) ports.