SMC Corporation of America
Elite Part Number Search
Search Results "ISE10-M5-C-PGR"

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, VACUUM SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JC, ZSE30

Please contact us for the latest version.sales@ocaire.com, ISE30 M5 PT VERSION, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.21949 lb

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage)

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -

Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -

Please contact us for the latest version.sales@ocaire.com, ISE30 M5 PT VERSION, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.15747 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, OTHER NO SIZE RATING, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X,

Please contact us for the latest version.sales@ocaire.com, ISE30 M5 PT VERSION, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.22046 lb

ISE30 M5 PT VERSION, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.22046 lb

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]