CYLINDER, H1, 20MM CM PART, .00220 lb
NSF-H1 food grade grease option is available. Bore sizes: 20, 25, 32, 40, 50, 63 mm; Stroke lengths (20, 25 bore): 20, 30, 40, 100, 150, 200 mm; Stroke lengths (32, 40, 50, 63 bore): 25, 50, 100, 150, 200 mm; FKM, fluoropolymer seal option; NSF-H1 food grade grease option; Auto switch capable
www.stevenengineering.com I 2.99 ANCILLARY VALVES SERIES ASP D I M E N S I O N S ( M M) S E R I E S ASP D I M E N S I O N S (I N C H) S E R I E S ASP L4 Max Min Weight g Model d T1 T2 H1 H2 D1 D2 D3 L1 L2 L3 L5 *A1 *A2 M 39.6 34.6 32 ASP330F-01-06S 6 R(PT)1/8 M5x0.8 12 8 11.6 14.2 11.8 14 38.4 22.9 39.5 35.2 10.5 13.7 38.9 33.9 35 ASP330F-01-08S 8 R(PT)1/8 M5x0.8 12 8 15.2 14.2 11.8 15.8
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly
Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water)
Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 008 (8 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 8 kW, Type: -, Pump Inverter Control: -, Option: -
Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: -, Option: -
Cooling Capacity: 8 kW, Type: Fluorinated Fluid, Pump Inverter Control: Pump Inverter Type, Option: -
Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: Pump Inverter Type, Option: -
Cooling Capacity: 8 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: -
Cooling Capacity: 1kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 8kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 2kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 4kW, Temperature Set Range: 20°C to 90°C, Option: -
Cooling Capacity: 002 (2 kW), Type: 1 (Ethylene Glycol)