SMC Corporation of America
Elite Part Number Search
Search Results "HRSH200-AN-20-AS"

Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. Mounting Position As a rule, the unit must be installed horizontally.

Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. Mounting Position As a rule, the unit must be installed horizontally.

Combination Symbol: K2 Combination Symbol: K7 An N.C. solenoid valve is used as the supply valve. Also, an external 2 port valve (vacuum valve) must be provided to serve as the vacuum release valve. An air operated N.O. valve is used as the supply valve. An N.C. solenoid valve is used for the vacuum release valve.

As a result, the inside of the bowl q is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.

Note 2) 4 to 20 mA DC is not possible with the 2-wire type. Power supply voltage (24 VDC or 12 to 15 VDC) is required. Note 3) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 350 or less for an input current of 20 mA DC.

This system should not be applied with an undue force such as caused by piping installation.

This product cannot be used as a check regulator by installing it between solenoid valve and actuator. 3. Port with a pressure gauge or a plug can be used as an OUT port.

Use caution, as operating above the prescribed values may lead to dropping of the load. The cushion effect (smooth start-up, soft stop) exists only before the stroke end in the stroke ranges indicated in the table below. The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or return from an intermediate stop using an external stopper, etc.

Manual Override Caution Light/Surge Voltage Suppressor Caution Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Push type is standard. Locking type (Tool required) is available as an option. 1.

Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of moisture can cause malfunction of pneumatic equipment such as rotary tables. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator. 4.

F = x 4 = 10 x mg mg 2 x 0.2 F = x 4 = 20 x mg mg 2 x 0.1 Note) Even in cases where the coefficient of friction is greater than = 0.2, for reasons of safety, select a gripping force which is at least 10 to 20 times greater than the workpiece weight, as recommended by SMC.

Mixed single and double wiring are available as an option.

an inertial load. ( ) 1 2 3 7 10 20 30 50 70 100 200 (Example) Clamp F: Pressing force (N) l Static torque calculation Ts = F x l (Nm) Shaft center Note) Effective torque values are representative values and not to be considered as guaranteed values.

No freezing (for cylinders with or without an auto switch) Bore Size/Standard Stroke Symbol Specifications (mm) XA Change of rod end shape Rod end configuration XC3 Special port location Bore size (mm) Round bar, Chamfered type Roller type Lever type with shock absorber 12 10 10 16 10, 15 10, 15 20 10, 15, 20 10, 15, 20 32 10, 15, 20 40 Spring Force (Single acting) 20, 25, 30 20, 25, 30

Also, applicable for use in an environment with water splashing such as food processing and car wash equipment, etc.

/25 REAH15/20/25 REAH15/20/25 REAH15, 20 REAH15, 20 REAH25 REAH15, 20 REAH25 0.08 0.03 REAH25 Deflection (mm) Deflection (mm) Deflection (mm) Deflection (mm) 0.02 0.06 0.02 0.04 0.01 0.01 0.02 5 10 15 20 0 25 25 25 5 10 15 20 0 Moment (Nm) 5 10 15 20 0 Moment (Nm) Moment (Nm) REAHT25/32 REAHT25/32 REAHT25/32 0.05 REAHT25 REAHT25 REAHT32 REAHT32 REAHT25 0.03 Deflection (mm) Deflection (mm)

Do not use an air cylinder as an airhydro cylinder. If it uses turbine oil in place of fluids for cylinder, it may result in oil leakage. 4. The oil stuck to the cylinder is grease. 5. The base oil of grease may seep out.

Do not use One-touch fittings in the piping for an air-hydro cylinder, as oil leakage may occur. 2. For air-hydro cylinder piping, use hard nylon tubing or copper piping. As in the case of hydraulic circuits, surge pressures greater than the operating pressure may occur in an air-hydro cylinders piping, making it necessary to use safer piping materials. Caution 1.

The grounding point should be as near as possible to the controller, to keep the grounding cable as short as possible.