Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.
Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.
Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: None, Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 200 (20.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKM (A + K + M)
Cooling Capacity: 400 (CH1: 37 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: M (Applicabe to DI Water Piping)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: M (Applicabe to DI Water Piping)
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: M (Applicabe to DI Water Piping)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: M (Applicabe to DI Water Piping)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: M (Applicable to Deionized Water Piping)
Cooling Capacity: 15.7 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: Applicable to DI Water Piping
Cooling Capacity: 20.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: Applicable to DI Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping
Cooling Capacity: Cooling Capacity: 3800W/4200W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]