Bore size 40 mm (1-1/2) 50 mm (2) 63 mm (2-1/2) Stroke Hundredths of an inch* 20 25 32 40 50 63 20 mm (3/4) 25 mm (1) 32 mm (1-1/4) Stroke length must be indicated as 4 digits.
P Reduced apparent power Conventional: 5.6 VA 1.55 VA Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown below.
mA Fault current (FDE): 3.9 mA FOUNDATION fieldbus function block execution times ND9000F AO 20 ms AI 20 ms PID 20 ms DO 20 ms DI 15 ms IS 15 ms OS 15ms 7 ND90 71 en 7 Approvals Table 1 Approvals and electrical values, HART Certificate Approval Electrical values ATEX ND_X VTT 09 ATEX 033X VTT 09 ATEX 034X II 1G Ex ia IIC T6...T4 Ga II 1D Ex ta IIIC T90 C Da II 2 G Ex ib IIC T6...T4 Gb II
Analogue output Output impedance Approx. 1 k Output current (rated pressure range) 4 to 20 mA 2.5% F.S. 2.4 to 20 mA 2.5% F.S. outpour 3 Current Linearity 1%F.S.
Auto switch operating range (mm) Time load applied (ms) x 1000 V (mm/s) = In cases of high piston speed, the use of an auto switch (G5NTL) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 2. Keep wiring as short as possible.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.
When designing an application, be sure to allow sufficient space for maintenance and inspection. In cases of high piston speed, the use of an auto switch (DF5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
When designing an application, be sure to allow sufficient space for maintenance and inspection. In cases of high piston speed, the use of an auto switch (DF5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
An Alarm condition will happen during all other times. Keep the input signal combination for 15 ms (30 ms if possible) or longer. -Output terminalNo. Function Description B1 OUT0 When the operation is started and DRIVE is turned OFF, a Bit no. corresponding to the number of the active step data will be output from these terminals.
(Writing time: 10,000 times, Data duration: 20 years after power off) Use the clean air. This can cause operating failure. If compressed air containing condensate is used, install an air dryer or drain catch before the filter and perform drainage regularly.
Tightening of M3 and M5 screws 1) After tightening by hand, the barb elbow type (M-3ALU-2, M5ALHU-2) should be tighten an additional 1/3 rotations using an appropriate wrench. 2) After tightening by hand, other types should be tightened by an additional 1/6 rotations using a suitable tool.
(Standard: 80 mm-pitch) Maintenance detection level selection switch KJH04-M5-X34 30 20 Position Detection Switch Flow Sensor Pressure Control Pressure Sensor Balance adjustment trimmer 14 19 20 16 Note) The maximum bar length is 1260 mm. The air purge nozzles are arranged at an 80 mm-pitch.
voltage 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC Power consumption 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Between case and AC line: 1500 VAC for 1 min.
Install an air filter. Install an air filter upstream, near the valve. Select an air filter with a filtration degree of 5 m or finer. 2. Compressed air containing large amounts of drainage can cause malfunction of pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or drain catch. 3. Ensure that the fluid and ambient temperature are within the specified range.
Response time 1.5 s (100 ms) Voltage output Output voltage : 1 to 5 VDC Output impedance : 1 k Analogue output Output c urrent : 4 to 20 mA Current output Max. load impedance: 600 (24 VDC) Min. load impedance: 50 Accuracy 1%F.S. max.
An injury or failure can result. 1. Pay attention to the length of time that a switch is ON at an intermediate stroke position.
D-MS-A Mounting screw (M2.5 x 4 L, Steel (Black zinc chromate)) 1 pc. D-MS-AP Mounting screws (M2.5 x 4 L, Steel (Black zinc chromate)) 10 pcs. D-MS-B Mounting screw (M2.5 x 4 L, SUS) 1 pc. D-MS-BP Mounting screws (M2.5 x 4 L, SUS) 10 pcs. ISA-2-1 DIN rail (Width 35 mm x Length 105 mm) 1 pc. ISA-2-2 DIN rail (Width 35 mm x Length 140 mm) 1 pc.
p 1o 12 stalons Lateral Plug.in Style Manifold series VQCI 000/20044000 r t Fast response times and long service life VQCl100: 10 ms 2 ms; 200 million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles ( ( I T CE compliment " , t 4-position dual 3-pod valves for independent control of A & B ports Availabe conf igurations IN.C.A.C.], lN.O /N.O l, and [N.c
Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown below. Built-in strainer in the pilot valve Unexpected troubles due to foreign matter can be prevented. Note) Be sure to mount an air filter on the inlet side.
SI unit SI unit Refer to fault PWR LED and malfunction No.1 MS LED is OFF SI unit Refer to fault PWR(V) LED is OFF No.2 Yes No SI unit Refer to fault MS LED is red No.3 SI unit Refer to fault MS LED is red flashing No.4 SI unit SI unit Refer to fault MS LED is green flashing NS LED is OFF No.5 SI unit Refer to fault NS LED is red No.6 SI unit Refer to fault NS LED is red No.7 flashing SI