Mixed single and double wiring is available as an option.

Intermediate stop In the case of 3-position closed center of a valve, it is difficult to make a piston stop at the required position as accurately and precisely as with hydraulic pressure due to compressibility of air. Furthermore, since valves and cylinders, etc. are not guaranteed for zero air leakage, it may not be possible to hold a stopped position for an extended period of time.

Maintaining an Unlocked Condition Warning Piping Port / Switch Mounting Rod (by-pass piping) Position Change Warning 1. To maintain an unlocked condition, be sure to follow the steps shown below.

Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 20Data Stop signal Amount of overrun 6-12-29 30 Series C95N Specific Product Precautions 2 Be sure to read before handing. Adjustment Pneumatic Circuit Mounting Warning Warning Warning 2. Do not apply an offset load to the piston rod.

Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads. If the size of the wrench is not suitable for the hexagon wrench flats, the wrench flats may be crushed. Mounting Caution 1. Before mounting confirm the model and size, etc.

Select the type with release pressure supply port (PD) as an option.

Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator. 4.

Keep wiring as short as possible. Although wire length should not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch. When designing an application, be sure to allow sufficient clearance for maintenance and inspections.

Environment at an altitude of 1000 meters or higher Heat radiation and withstand voltage will decrease. Contact SMC for details. (2) Do not use in an environment where the product is directly exposed to liquid, such as cutting oils.

Do not perform unlocking when an external force such as a load or spring force is being applied. This is very dangerous because the cylinder will move suddenly.

Do not perform unlocking when an external force such as a load or spring force is being applied. This is very dangerous because the cylinder will move suddenly.

When designing an application, be sure to allow sufficient space for maintenance and inspection. In cases of high piston speed, the use of an auto switch (DF5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

workpiece as shown in the figure below.

Do not perform unlocking while an external force such as a load or spring force is being applied. This is very dangerous because the cylinder will move suddenly.