KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in) ZZ PC KK Y R XT G A LD Bore (in) DD C NT ND AA EA D B MM WF P K E SN TN EE 9.44 1.30 7/16-20 1.71 1.43 1 15/16 1.26 3/4 7.44 150 (1.5") 1/4-28 3/8 1/4-20 9/32 2.02 0.3 9/16 1 1/8 5/8 1 2.36 9/32 2 5.56 5/8 3/8 9.52 1.30 7/16-20 1.71 1.84 1 15
The following graph shows an example of the detection of an overload warning when the overload warning level (Pn52B) is changed from 20% to 50%. An overload warning is detected in half of the time required to detect an overload alarm.
B B B B 3.2 31.2 P R (4.4) 32 15.3 7.5 17 16 A A A A A 1 (Station n) (Station 1) L1 L2 4.5 (Pitch) P = 10.5 (Light/surge voltage suppressor) 15.5 15.5 (Station n) (Station 1) + + (Light/surge voltage suppressor) A A 20 15 5 48.5[55.5] B B + + 1.5 One-touch fitting (A, B port) Applicable tubing O.D.: 4 and 5/32" (Pitch) P = 10.5 16 33.1 A A 20 15 B B 5 1 (Pitch) P = 10.5 16.5 M5 x 0.8 (A,
to 50 M N Bracket (See table below.) 4-O T Q 2-P AH AG B S W K U L AA AL AB A I J AI AJ 4-AK hole V AP R Y + Stroke Z + Stroke X AG For 4-AO AN AI Cutout window AM Mounting dimensions For standard strokes (mm) Bore size (mm) Stroke range (mm) O N M L K J I B AP AO AN AM AH AG AB AA AL AK AJ AI A 20 25 32 40 50 75, 100, 125, 150, 200 M6 x 1 depth 9 45 25 80 60 55 30 108 25 M6 115 65 125 112
MGC series 20 to 50 MGC Series (mm) C port SZ + Stroke B Cushion valve (Width across flats WH) Front mounting flange Bore size (mm) GC GD SA SB W 1 W 2 A, B port A port W 2 W 1 A 20 25 32 40 50 30 30 21 9 50 87 30 30 C port D port 21 9 50 87 B port W 2 W 1 10 A' 25 30 23 9 52 91 20 20 24 8 59 99 Cushion valve (Width across flats WH) D port ZZ + Stroke A + Stroke B SB + Stroke B SA + Stroke
Arm (mm) F D E C B A F E D C B A G Model MK2TG32 MK2TG40 MK2TG50 MK2TG63 Model MK2T32-N MK2T40-N MK2T50-N MK2T63-N 56 34 48 65 5.5 8 15 to 25 21.5 45 20 67 18 M8 x 1.25 62 40 54 72 5.5 8 15 to 25 21 45 20 67 18 M8 x 1.25 76 50 67 89 6.6 9 20 to 40 29.5 65 22 88 22 M10 x 1.5 92 60 80 108 9 9 20 to 40 34.5 65 32 91 32 M10 x 1.5 S N N T I thread length J 2 x 4 x M thread 2 x V U O A C D B P
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) B 15 16 A 12 13 B 19 20 A 11 12 B 18 19 A 8 9 SMC D-A90 20 25 SMC D-A90 A Approx.
W/o auto switch B L L1 With auto switch Bore (mm) 5st 10 A 20 20 20 20 5st 10 5st 10 5st 10 32 48 58 12 33.5 58 68 17 38.5 40 64.5 12 33.5 64.5 74.5 17 38.5 45.5 50 67.5 77.5 18 43.5 87.5 97.5 28 53.5 Rod end male thread Double clevis (mm) A Without auto switch B CL A B CL With auto switch Bore (mm) Double clevis/CQ2D, CDQ2D 5st 10 20 20 20 20 20 20 5st 10 5st 10 5st
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or return from an intermediate stop using an external stopper, etc. RE A B Reference values for non-rotating accuracy and maximum allowable moment at stroke end are indicated below.
(mm) D-A9, D-A9V D-M9, D-M9W D-M9V, D-M9WV Bore size (mm) A B W A B W A B W 6 10 16 20 25 32 13.5 5.5 3.5 (1) 17.5 9.5 0.5 17.5 9.5 1.5 12.5 9.5 7.5 (5) 16.5 13.5 3.5 16.5 13.5 5.5 16 11.5 9.5 (7) 20 15.5 5.5 20 15.5 7.5 20 15 24 19 9 24 19 11 13 (10.5) 22.5 16 26.5 20 10.5 26.5 20 12.5 14.5 (12) 23.5 18.5 27.5 22.5 12.5 27.5 22.5 14.5 16.5 (14) Note 1) Figures in the table above are used
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or return from an intermediate stop using an external stopper, etc. RE A B Reference values for non-rotating accuracy and maximum allowable moment at stroke end are indicated below.
(Red Green Red) D-B59W D-A79W D-A59W D-H7NW/H7PW/H7BW D-G59W/G5PW/K59W D-F79W/F7PW/J79W D-F7NWV/F7BWV D-F59W/F5PW/J59W D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV D-Y7NW/Y7PW/Y7BW Band Grommet 10-20-23 Solid state switch Reed switch Rail Grommet 10-20-24 Tie-rod Grommet 10-20-25 2-color indication 10-20-42 Band Grommet RE A B 10-20-43 10-20-44 Rail Grommet REC 10-20-45 Tie-rod Grommet 10-20-46
Enable Generates an error. Unit 1 Disable Does not generate an error. 0..10 V 0..5 V Sets the range of the analogue output device. 2 Analogue output range Selects the analogue output range. 0..10 V Channel 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary. Sign & Magnitude Signed binary.
HRG001--B HRG002--B HRG005--B HRG010--B HRG015--B Applicable model 3 Pole number 30 Rated current sensitivity (mA) Ground fault circuit interrupter 10 5 20 40 60 Rated shutdown current (A) Short circuit display method Mechanical button Breaker mounting location Remove the front panel.
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
D-A9, D-A9V D-M9, D-F9W D-M9V, D-F9WV Bore size (mm) B W A W W B B A A 6 10 16 20 25 32 9.5 1.5 17.5 0.5 5.5 9.5 13.5 17.5 3.5(1) 13.5 5.5 16.5 3.5 9.5 13.5 12.5 16.5 7.5(5) 15.5 7.5 20 5.5 11.5 15.5 16 20 9.5(7) 19 11 24 9 15 19 20 24 13(10.5) 20 12.5 26.5 10.5 16 20 22.5 26.5 14.5(12) 22.5 14.5 27.5 12.5 18.5 22.5 23.5 27.5 16.5(14) Note 1) Figures in the table above are used as a reference
8m to 20m)] Signal name Terminal (a) (b) LE CP B Cable colour Terminal number number Brown 2 A B-1 Red 1 A A-1 Cable length [L] Orange 6 B B-2 Yellow 5 B A-2 8 8mNote) Green 3 COM-A/COM B-3 Blue 4 COM-B/ A-3 A 10mNote) (c) Shield B 15mNote) Cable colour Terminal number Brown 12 Vcc B-4 C 20mNote) Black 13 GND A-4 Red 7 A B-5 Note) Produced upon receipt Black 6 A A-5 Orange 9 B B-6 of order
integral compensation 20 50 20 7 15 7.
@ ZP3-T(04/06/08)B;(JB/K)15-@ ZP3-T(04/06/08)UM(JB/K)20-@ ZP3-T(04/06/08)B;(JB/K)20-@ ZP3B-T2A(J/K)3-B5 Note 1) ; in the table indicates the pad material.
@ ZP3-T(04/06/08)B;(JB/K)15-@ ZP3-T(04/06/08)UM(JB/K)20-@ ZP3-T(04/06/08)B;(JB/K)20-@ ZP3B-T2A(J/K)3-B5 Note 1) ; in the table indicates the pad material.