Grease (10g): 1 bag 80 CA2Y80-PS 100 CA2Y100-PS 40 CA2Y40Z-PS Piston seal: 1 pc. 50 CA2Y50Z-PS Rod seal: 1 pc. 63 CA2Y63Z-PS CA2Y Tube gasket: 2 pc. 80 CA2Y80Z-PS Grease (10g): 1 bag 100 CA2Y100Z-PS 20 CM20Z-PS 25 CM25Z-PS CM2Y Rod seal 32 CM32Z-PS 40 CM40Z-PS 20 CG1Y20Z-PS Piston seal: 1 pc. 25 CG1Y25Z-PS Rod seal: 1 pc. CG1Y 32 CG1Y32Z-PS Tube gasket: 1pcs.
Air supply The air supplied to the lock unit should be filtered by SMC AF series air filter and regulated to the specified set pressure by SMC AR series regulator. W a r n i n g Type of fluids Please contact SMC when using the product in applications other than with compressed air.
Made-to-Order nozzle product names / Piping examples Made-to-Order nozzle Supply pressure product number specifications Circular diffusion nozzle IZN10-G-X198 0.05 to 0.1 MPa Flat diffusion nozzle IZN10-G-X199 0.05 to 0.1 MPa Bar nozzle (straight type) IZN10-G--X216 0.05 to 0.1 MPa Circumferential jet bar nozzle (straight type) IZN10-G-X278 0.05 to 0.15 MPa Bender tube nozzle IZN10-G--X205
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 9 Position for application of grease Table 10 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 20 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.9, ) Pay attention to the mounting direction of the seal.
Lock specifications Bore size (mm) 20 25 32 40 50 63 80 100 Lock operation Spring locking (Exhaust locking) Unlocking pressure 0.2 MPa or more Lock starting pressure 0.05 MPa or less Locking direction One direction (Extension locking, Retraction locking) Maximum operating pressure 1.0MPa Unlocking port size (Rc, NPT, G) Port size (Rc, NPT, G) M5 x 0.8 1/8 1/4 Holding force (Maximum static
Grease apply amount( g ) 2 125 140 160 180 200 250 320 Portion to apply 100st 15~17 20~22 24~26 27~29 30~32 33~35 36~38 ~ 50st Up 3 3 3 4 4 5 5 For grease, use lithium soap group grease JIS #2 3. Mounting seal . Cushion seal/Rod seal /Scraper Mount in correct direction. N .
Air supply The compressed air supplied to the cylinder should be filtered by SMC AF series air filter and regulated to the specified set pressure by SMC AR series regulator. W a r n i n g Type of fluids Please consult with SMC when using the product in applications other than compressed air. When there is a large amount of drainage.
W a r n i n g ~ Design a circuit to prevent sudden action of a driven object.
Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4
The lock unit for 40 G MWB40TF-UA maintenance is supplied with lock released state at the shipment from the factory. 50 G MWB50TF-UA 63 G MWB63TF-UA 80 G MWB80TF-UA 100 G MWB100TF-UA For lock unit with bellows, please add -J to the part number suffix. Ex.)
IZS40 IZS41 IZS42 0 1 Remote Remote controller *1 controller *1 1 3 1 0.1 2 5 3 0.5 3 8 5 1 4 10 10 3 5 15 15 5 6 20 20 10 7 30 30 15 8 DC + DC + 20 9 DC DC 30 *1: Set when remote controller is used. 5-3-2.
(Figure-20-3) Fix the cylinder with screws included as accessories after confirming that there is no interference between the lever and the proximity switch. Figure-20-1 Figure-20-2 Figure-20-3 20 - 9. Troubleshooting Detail of trouble Cause Countermeasure Operation is not smooth 1. Lubrication failure Clean components and apply specified grease to them. 2.
Clean series 10 AF 03 A 30 F J B 21 AF 03 A 30 F J B Copper, fluorine and silicone-free + Low particle generation q w e r t Air filter Option/Semi-standard:Selectoneeachfora to e. Option/Semi-standardsymbol:Whenmorethanonespecificationisrequired,indicateinalphanumericorder.
Series AFM modular style mist separator is available in body sizes 20, 30, and 40, and is offered with Rc, NPT or G thread types. The AFM's standard filtration is 0.3µm with a 99.9% filtered particle size. The modular design allows connection with other SMC air preparation equipment. Use in combination with the AF series to meet your clean room filtration requirements.
Series AFM modular style mist separator is available in body sizes 20, 30, and 40, and is offered with Rc, NPT or G thread types. The AFM's standard filtration is 0.3µm with a 99.9% filtered particle size. The modular design allows connection with other SMC air preparation equipment. Use in combination with the AF series to meet your clean room filtration requirements.
267 330 Foot: 231 207 253 L G 193 172 212 144 126 156 109 94 118 90 78 97 Rod side Frang e F Head side flange 433 386 476 Foot: 334 297 367 L G 281 250 309 210 185 229 160 141 175 134 117 129 8 - 5) Theoretical output Table 3.
are used 200 200 When 20 units are used 77% reduction Current model IR3000 Series 91% reduction 38000 yen reduction 150 150 117000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1000-A Series IR2000-A Series IR3000-A Series 50 50 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Released into atmosphere IR Special bleeding structure No fixed throttle in the new
Maintenance timin g detection detection Internal processing contents Internal processing contents Offset voltage Offset voltage ajustment ajustment may therefore be charged.
Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 4) H Mounting Without mounting option With bracket With set nut a + Without auto drain Float type auto drain (N.C.)
Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 4) H Mounting Without mounting option With bracket With set nut a + Without auto drain Float type auto drain (N.C.)