A Series MGC 20 to 50 SZ + Stroke B D port C port A, B port B port A C port A port D port A View A-A GD GD Front mounting flange SB + Stroke B SA + Stroke A ZZ + Stroke A + Stroke B Bracket mounting With R Without R Stroke A stroke Stroke A + Stroke B ( ) Bore size (mm) W1 W2 SB SA GD ZZ GC SZ availability 30 30 Up to 200 96 50 9 176 21 20 35 st or more 89 110 30 30 96 50 9 183 21 25 60 st
: m (kg) 30 16 20 10 When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large. 4 5 3 Caution 2 Handling precautions Note 1) When using as a stopper, select a model with a stroke of 25mm or less. 1 5 10 20 30 40 50 Note 2) Model MGPL (ball bushing) cannot be used as a stopper.
] R P R 63.8 (DIN 65.1) 63 (DIN 64.3) R P R B B B B B 122 [126.4] 19 19 19 60 31.5 22 A A A A A 1/4 (P, R port) 13.8 (For DIN: 15.1) 4-4.5 (For mounting) (Pitch) P = 20 29 Manual override (Station n) (Station 1) (Light/surge voltage suppressor) + + + 73 [80] 57.6 A A 10.5 41 30.5 B B 6.5 (Pitch) P = 20 25 1/8 (A, B port) L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector
External Connection (P.20) for wiring. Refer to section 17.
Driver Inrush currents (A0-P) Main circuit power supply (L1, L2, and L3) Control circuit power supply (L11 and L21) LECSN2-T5/ LECSN2-T7/ LECSN2-T8 30 A (attenuated to approx. 3 A in 20 ms) 20 A to 30 A (attenuated to approx. 1 A in 20 ms) LECSN2-T9 34 A (attenuated to approx. 7 A in 20 ms) 10 8 11. OPTIONS AND PERIPHERAL EQUIPMENT 11.
station (S1 unit) SG B A SG B A FG SG B A FG SG B A FG FG Power supply 24 V 0 V Twisted pair wire with shielding DG 1-6-115 Base Mounted Series SX3000/5000 SX5000: Serial Transmission Unit/Plug-in C4 C6 C8 SS5X5-45SStations U(Pitch) P = 16 DIN rail release button 2-One-touch fittings (P , R port) Applicable tubing O.D.: 10 2n-One-touch fittings (A, B port) Applicable tubing O.D.: 4, 6, 8
Contact P/A for more details.
Note 3) Bowl assembly for AF30 to 60 models comes with a bowl guard (steel band material). 26 AF10 to 60 Dimensions L AF10, 20 L AF50, 60 Bracket (Option) D A G D Bracket (Option) F M G K K F J M J H E B B E H IN OUT IN C OUT C OUT Port size OUT Port size o s AF10: 25 AF20: 40 Drain A P Min. clearance for maintenance AF30, 40, 40-06 L Bracket (Option) A D G F M K J B E Drain IN Min. clearance
Driver Inrush currents (A0-p) Main circuit power supply (L1, L2, L3) Control circuit power supply (L11, L21) LECSC2-T5 LECSC2-T6 LECSC2-T7 LECSC2-T8 30 A (attenuated to approx. 3 A in 20 ms) 20 A to 30 A (attenuated to approx. 1 A in 20 ms) LECSC2-T9 34 A (attenuated to approx. 7 A in 20 ms) 12 7 13. OPTIONS AND AUXILIARY EQUIPMENT 13.
Thermo Chiller, HRS090 AND LARGER CAPACITIES, O88, 134.00000 lb
/See 6.3 Caution (1) on p.36 Operate within the specified 4) Excessive external force is range. being applied, (including /See 2.1 Specifications on p.9 vibration) or impact load. /See 3.1 Specifications on p.12 Motor may take about 20sec This is not a malfunction. After power supplied, when first to find the motor phase.
p. 17 Internal Circuits and Wiring Examples a p. 19 Dimensions a From p. 20 16 ZSE20(F)/ISE20 Series Set Pressure Range and Rated Pressure Range Set the pressure within the rated pressure range.
10 20 10 20 10 20 6 10 20 10 20 10 20 10 20 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 P.2 Horizontal 10 10 P.10 Standard motor 6 6 P.18 Vertical 10 10 P.26 Frame-type linear guide LTF 6 6 P.34 Horizontal Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 10 P.42 Non-standard
VJ10-20-4A-6 2 pcs. ZY 6 4A 20 VJ10 6 10 15 20 25 30 0.6 m 5A 20 ZS ZF For ZSE3 1 m (For 100 VAC) 1.5 m Note) If ordering a vacuum switch with 3 m lead wire, specify both the vacuum unit switch and the 3 m lead wire with connector part numbers. Ordering example) ZX1051-K15LOECN(-Q) 1 pc. VJ10-20-4A-6 2 pcs.
: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Applicable connector: Flat ribbon cable connector (20P) (Conforming to MIL-C-83503) VQZ D side n Stations 8 7 6 5 4 3 2 1 U side VQD P P A A A A A A A A 2-C6 P (SUP port) 24.5 (11) 13.5 B B B B B B B B R R 7 P = 11 19.2 2-C6 R (EXH port) (7.5) 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting
0.6 55 50 70 15 76 96 13.5 20 19 11 353.5 393.5 Rotating Angle Bore size [mm] A B A + B + 90 32, 40 25 45 160 50, 63 40 60 190 80, 100 30 55 175 32 C96N Series Construction (Double Rod) @0!
Note 1) Type V is not applicable because it is equipped with a relief type 3 5 20 60 75 100 Nil 20 25 50 100 200 600 750 1000 regulator. (Symbol P is used when it is undesirable for the air to be discharged into the main body of IDG.
adapter Vertical VAC VAC ZP3-T VAC p. 138 p. 144 p. 150 p. 156 With adapter Lateral ZP3-Y Construction Precautions Mounting Bracket Assembly VAC VAC VAC p. 139 p. 145 p. 151 p. 157 With adapter VAC VAC VAC Vertical ZP3-T p. 140 p. 146 p. 152 p. 158 With buffer Lateral ZP3-Y p. 141 p. 147 p. 153 p. 159 With buffer VAC VAC VAC 134 Compact Type ZP3 Series Specifications Pad Material Material
40 50 63 80 100 A AL B B1 BN BP BQ C D E F GA GB GC GD GL GL1 GR H H1 J K Up to 500 30 27 60 22 96 1/8 1/8 44 16 32 10 85 15 50 16 12 12 10 51 8 M8 x 1.25 6 Up to 600 35 32 70 27 108 1/4 1/8 52 20 40 10 95 17 56 20 13 15 12 58 11 M8 x 1.25 7 Up to 600 35 32 86 27 115 1/4 1/4 64 20 40 10 102 17 65 20 18 12 15 58 11 M10 x 1.25 7 Up to 750 40 37 102 32 139 1/4 1/4 78 25 52 14 123 21 79.5 20
Model Port size P B B1 E F C D J K M Grommet Q R 20 VDW1 VDW2 M5 42.5 15 4 11 15.5 30 20 10 6 11 M2.5 M5, 1/8 52 5 15 17 36.5 22 11 8 13.5 M3 Body material Stainless Steel Grommet D 300 Q F Full wave rectifier (AC type) R E C A 2 x P Port size B B1 M 2 x J thread depth K (mm) Mounting method Electrical entry Model Port size P A B D E F B1 C J K M Grommet Q R 52 VDW1 VDW2 12 20 15 6 11 M2.5