G46-10-01) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter N. Please contact SMC concerning the supply of NPT pressure gauges. Relieving type is provided as standard for AU100.

Specifications 5 Model 7 Note2) FGGLD Note 1) FGGLC Note 1) FGGLB Note 1) FGGSD Note 1) FGGSC Note 1) FGGSB Note 1) Number of elements 14 65 x L250 7 Note2) 21 65 x L250 7 Note2) 28 65 x L250 Stainless steel 304 Stainless steel 304 28 65 x L250 7 Note2) 14 65 x L250 7 Note2) 21 65 x L250 7 Note2) 65 x L500 65 x L750 65 x L1000 65 x L500 65 x L750 65 x L1000 Element size Cover Case O-ring

Specifications 5 Model 7 Note2) FGGLD Note 1) FGGLC Note 1) FGGLB Note 1) FGGSD Note 1) FGGSC Note 1) FGGSB Note 1) Number of elements 14 65 x L250 7 Note2) 21 65 x L250 7 Note2) 28 65 x L250 Stainless steel 304 Stainless steel 304 28 65 x L250 7 Note2) 14 65 x L250 7 Note2) 21 65 x L250 7 Note2) 65 x L500 65 x L750 65 x L1000 65 x L500 65 x L750 65 x L1000 Element size Cover Case O-ring

Display Pressure: 7 (0.7MPa), Connection Thread: 01 (R 1/8), Option: X2 (Stud Parts Nickel Plated)

Pressure Gauge: G33 (ø30 Outside Diameter, Back Side Thread), Display Pressure: 7 (0.7MPa), Connection Thread: 01 (R 1/8), Option: X2 (Nickel Plated)

Pressure Gauge: GA33 (ø30 Outside Diameter, Vertical Side Thread), Display Pressure: 7 (0.7MPa), Connection Thread: 01 (R 1/8), Option: X2 (Nickel Plated)

(with cover anti-scattering mechanism) 32 B Industrial Filter FGG Series Specifications FGGLD Note 1) FGGLC Note 1) FGGLB Note 1) FGGSD Note 1) FGGSC Note 1) FGGSB Note 1) Model Port size (Rc) 2 Max. operating pressure (MPa) 0.7 FGD Operating temperature (C) 0 to 80 (60 with pressure gauge) Number of elements 21 7 Note 2) 28 7 Note 2) 14 7 Note 2) 21 7 Note 2) 28 7 Note 2) 14 7 Note 2) FGE

Pressure Gauge: ø42 Outside Diameter, Back Side Thread, Display Pressure: 0.7MPa, Connection Thread: R 1/8, M5 Female, Attachment: Clear Cover Removable, Wrench Tighten, Option: -

AR4 5 AR6 5 AR8 5 AR9 5 Description Model Pressure gauge with limit indicator Note 1) B24P B25P Bracket G46-10-02 (Max. 1.0 MPa), G46-2-02 (Max. 0.2 MPa) Note 1) In the gauge part no. (e.g. G46-10-02), indicate kind of the connecting thread. Put nothing for Rc and N for NPT thread. Please consult with SMC for NPT pressure gauge.

A B C2 D E Vacuum inlet direction q Pad dia.

7 CJ1 CJP CJ2 !5 !4 @ B @ C !3 JCM CM2 CM2 CM3 CG1 Boss-cut Integrated clevis CG3 Air-hydro !7 JMB MB MB1 CA2 CS1 With air cushion !7 CS2 Component Parts No.

A FY H S + Stroke H + Stroke ZZ + 2 x Stroke 4-FD 40 (mm) 7 5.5 5.5 5 K 14 12 10 8 D 21 19.5 19.5 15.5 AL 88 64 62 62 H 21.5 15 15 15 S 1/4 1/8 1/8 1/8 F P H1 7 7 7 7 FD FT FY 66 60 60 60 FZ 11 8 8 8 FX 188 154 152 144 G ZZ 52 40 40 34 B E 20-0.033 0 46.5 37.5 33.5 28 N 41 32 32 26 B2 47.3 37 37 30 I 24 22 22 18 C2 22 17 17 13 B1 45 41 41 37 H2 42.5 34.5 30 24 NA A M14 x 1.5 M10 x 1.25 M10

Mounting hole 1.5 ZZ + Stroke S + Stroke F FY 40 (mm) B WB 13 13 13 16 ZZ H H2 H1 B2 B1 80 80 82 108 F S 1/8 1/8 1/8 1/4 P A 20 25 32 40 AL 18 22 22 24 D 15.5 19.5 19.5 21 C2 34 40 40 52 FD 30 37 37 47.3 E 8 10 12 14 GC 13 13 13 16 FT 7 7 7 7 KA FL 10.5 10.5 10.5 13.5 FX 4 4 4 5 FY 60 60 60 66 FZ 36 Z 75 75 75 82 GA 8 8 8 11 GB 6 8 10 12 I 6 6 6 6 K 28 33.5 37.5 46.5 MM 5 5.5 5.5 7 NN 24


The part number of the standard AR20 to AR60 round type pressure gauge is “G36-10-01,” or “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.” Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-regulators&fa_id=10961


The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=combination-units&fa_id=10974

Refer to p.1.2-7 for further information.)

(If not specifying dimension C2, indicate instead.)

(If not specifying dimension C2, indicate instead.)

Form w 1 Material e r Vacuum inlet Connection thread N S U F GN GS HS 04 06 08 UM 02 10.8 7 2 1.4 KQ2H02-M5N C2 04 14.7 8 4 2.5 KQ2H04-M5N ZP3 Y B3 02 10.8 7 2 1.4 KQ2H02-M5N 04 14.7 8 4 2.5 KQ2H04-M5N 06 10 6 KQ2H06-M5N Vacuum inlet: One-touch fitting 10 13 16 Applicable tubing O.D.

E1 = E3 = D2 C1 = Y L1 max L4 Size (mm) 10 3 4 to 8 Y-2.5 L2 + 1.5 X L1 max L3 D1 Size D1 = Y2 = L4 = L2 = 15 C2 10 3 to 4 4.5 to 9 Y-3 L2 + 1.5 3 6 to 14 X-4.5 L1 + 1.5 C1 The standard chamfer may not be altered depending on the type of machining required. 20 15 3 to 5 5 to 10 Y-3.5 L2 + 2 3 to 4 7 to 18 X-5.5 L1 + 1.5 D2 = L1 = C2 = 30 L3 = 20 3 to 6 7 to 13 Y-5 L2 + 3 3 to 5 8 to 20