VXS VXS VXB VXE (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + T When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + T Conversion with sonic conductance C: VXP VXR VXH VXF VX3 VXA S = 5.0 x C(5) Q : Air flow rate[L/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream
This is the same concept representing the easy to run through as sonic conductance C (effective area). (3) Formula of flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + t When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + t Conversion with sonic conductance C: S = 5.0 x C(5) Q : Air flow rate[dm3/min(ANR)], dm3 (
AC200230V AC100120V 40 M5 3.24[Nm] M5 3.24[Nm] 6 AC100120V AC200230V AC100120V AC200230V L1 L1 PE PE L2 2-M5 2-M5 L2 L3 CNP1 CNP1 N N P1 P1 M4 1.2[Nm] P2 P2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L11 L11 L21 L21 U U CNP3 V CNP3 V W W 9 2 9 (2) LECSS-S8 [mm] 5 40 6 6 6 (80) (170) 6 6 () CN4 CN2L CN2 CN1B CN1A CN3 CN5 CNP1 L1 L2 L3 N P1 P2 P C D L11 L21 U V W L1 L2 () L3 N P1 CNP2 P2
Example: The figure below is based on the condition of set values as P1 = 40 [kPa] and P2 = 20 [kPa].
) (Pilot air port) Port 12(P1) (Pilot air port) e t w t Port 3(R) e r Port 3 (R) Port 2 (A) Port 1 (P) Port 23(P2) (Pilot air port) y i Port 2(A) u r y Port 1(P) t q VEX3320 (Air operated) VEX3420 (Air operated) w e q r y y t w r e u t t 12(P1), 23(P2) Port Port 3(R) y y (Pilot air port) r i Port 2(A) u r Port 1(P) t q Port 1(P) Port 2(A) Port 3(R) Component Parts No.
Driver Servo amplifier Servo motor M 4) P1-P2 (For 11kW or more, P1-P) should be connected. Driver Servo amplifier P1 P2 (c) When option and auxiliary equipment are used 1) When regenerative option is used under 3.5kW for 200V class The lead between P terminal and D terminal of CNP2 connector should not be connected.
In contrast with the N.C., when air is exhausted from the port 10(P2), the return spring opens the valve element. Pressurized air that enters through the port 10(P2) closes the valve element. Component Parts Material Bronze No.
Pilot port P1 and P2 piping Please arrange P1 and P2 piping as follows according to the model.
[inch] 4 x Applicable tubing L1 M P2 L2 P1 D1 A L3 1/4 1/8 KQ2ZD07-34lS 14.29 11.1 13.4 18.3 17.7 40.8 37.6 13.3 13.8 11.1 7.7 6.6 4.6 25.5 1/4 KQ2ZD07-35lS 14.29 11.1 13.4 18.3 21.1 44.2 39.8 13.3 13.8 11.1 7.7 6.6 4.6 32.4 3/8 KQ2ZD07-36lS 17.46 11.1 13.4 18.3 22.5 45.6 40.9 13.3 13.8 11.1 7.7 6.6 4.6 44.8 5/16 1/4 KQ2ZD09-35lS 19 13.2 17.6 21.95 22.4 49.2 44.8 14.2 15.9 13.2 20.5 14.2
Servo amplifier Servo motor Driver M 4) P1-P2 (For 11kW or more, P1-P) should be connected. Driver Servo amplifier P1 P2 (c) When option and auxiliary equipment are used 1) When regenerative option is used under 3.5kW for 200V class The lead between P terminal and D terminal of CNP2 connector should not be connected.
The valve element of the C.O. type, which has no return spring, is in an arbitrary position when air is exhausted through the ports 12(P1) and 10(P2). When pressurized air enters the port 12(P1) (exhaust from the port 10(P2)), the valve element opens, and it closes when pressurized air enters the port 10(P2) (exhaust from the port 12(P1)). Component Parts No.
(Return spring normally open) In contrast with the N.C., when the pilot solenoid valve is not energized (or when air is exhausted from the port 10(P2) of the air operated type), the valve body is opened by the return spring. When the pilot solenoid valve is energized (or when pressurized air enters through the port 10(P2) of the air operated type), the valve body closes.
-X4? to the end of part number.Ex.) TFU0604BU-2-10- X4--ModelTubing O.D. (mm)Tubing I.D. (mm)TFU042542.5
-X4? to the end of part number.Ex.) TFU0604BU-2-10- X4--ModelTubing O.D. (mm)Tubing I.D. (mm)TFU042542.5
2 8 4 3 9 4 0 V() X4 1 24 V(X5 2 10 5 3 11 4 0 V() X5 1 24 V() X6 2 12 6 3 13 4 0 V() X6 1 24 V() X7 2 14 7 3 15 4 0 V() X7 -23No.EX-OMN0035CN-A EX600-DXPF EX600-DXNF 0~7 1 24 V 0~7 1 24 V 0~7 2 0~7 2 4.7 k 4.7 k DC24 V DC24 V 0~7 3 0~7 3 4.7 k 4.7 k 0~7 4 0 V 0~7 4 0 V -24No.EX-OMN0035CN-A LED LED EX600-DXB/EX600-DXC OFF OFF ON EX600-DXC1 LED EX600-DXC1 LED
0 V (control and input) X7 0 V (control and input) X6 0 V (control and input) X5 0 V (control and input) X4 24 V (control and input) 24 V (control and input) 0 V (control and input) Signal name Signal name Input 15 Input 14 Input 13 Input 12 Input 11 Input 10 Input 15 Input 13 Input 11 Input 9 Input 8 Input 9 Input 7 Input 5 Input 3 Input 1 FE - 3 2 1 0 3 2 1 1 0 25 24 23 22 21 20 19 18
control pressure measurement value [high byte] UnitkPa 23 ITV control pressure measurement value [low byte] 24 ITV diagnostic data [high byte] 25 ITV diagnostic data [low byte] Air Management Hub internal error 2 Air Management Hub internal error 1 Port 3 short circuit VP short circuit 26 Reserved 27 ITV-PQI 28 Port 4 PQI Isolation input signal (Port 3) Standby input signal X2 (Port 4 input) X4
MHY MHW Heat Resistant Specifications 2 Grooves for Auto Switch on Both Sides 4 -X41 -X4 MRHQ MHK D 1 L 2 Bore size X4 F MHK 2 L D 1 F Bore size X41 Misc. Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.
Select x1, x2 or x4 with the UP/DOWN keys. x4 indicates multiplication by 4. Shift to the next item with the SEL. key. DOWN SEL. key (4) Setting the prescale value FUNC. Set the number to be added for each count. Shift the digits with the LEFT/RIGHT keys, and increase or decrease the numerical values with the UP/DOWN keys. Shift to the next item with the SEL. key.
MHY MHW Heat Resistant Specifications 2 Grooves for Auto Switch on Both Sides 4 -X41 -X4 MRHQ Bore size X4 F MHK D 1 L 2 MHK 2 L D 1 F Bore size X41 Misc. Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.