SMC Corporation of America
Elite Part Number Search
Search Results "E400-04-A"

Pad Bellows Pad For a workpiece that does not have a space for a buffer, or for a workpiece with a diagonal surface. Caution Guide for drop prevention If multiple pads are used for transporting a flat object with a large surface area, properly allocate the pads to maintain balance.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

AS1001FG-04-X12 ASP Ex.) AS1001FG-04-X21 Note) Not particle-free ASN Throttle Valve (Without Check Valve) X214 AQ Ex.) AS1001FG-04-X214 ASV AK Needle Valve/Flow Characteristics VCHC Note) The flow characteristics are representative values.

For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

M5 ground screw 9 9 2n-Rc 1/2 4(A), 2(B) port VQ0 U side 34.5 VQ4 n X 12 X 12 VQ5 B 2 A 4 6 B B B B B B A A A A A A VQZ B 2 A 4 VQD 5 SMC SMC SMC SMC SMC B 2 A 4 4 L1 L2 B 2 A 4 3 B 2 A 4 2 P = 41 P = 41 B 2 A 4 1 Cable length (600 or 1500 mm) 58.5 34.5 48 68.5 Stations D side 42 16 15.5 61.8 133 22 51 69 117 2-Rc 1/8 (External pilot port) Dimensions Formula: L1 = 41n + 76, L2 = 41n + 96

Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4). 108 108 AIR VENT M6 x P1 G1/2 AIR VENT M6 x P1 2 x RcD 2 x RcD C B A B OUT IN OUT IN C A DRAIN G1/4 DRAIN G1/4 (mm) (mm) A B D C A B D C Model Element length Model Element length A (L250) A (L250) 314 70 374 314 70 407 FGDC FGDE FGDC FGDE B (L500) B (L500)

Applicable model t ZH15DA-09-N03-11 ZH15DA-N02-N03-N03 2 Minimum C Factor of a Supply Valve Model C[dm3/(sbar)] ZH05A 0.12 ZH07A 0.23 ZH10A 0.47 ZH13A 0.80 ZH15A 1.06 ZH18A 1.53 ZH20A 1.88 ZH18DA-11-N03-13 ZH18DA-N03-N03-N03 1 ZH20DA-10-04-12 ZH20DA-03-04-04 ZH20DA-11-N04-13 ZH20DA-N03-N04-N04 t 2.

K J H G F E D C B A 475 432 512 472 525 482 562 522 L Booster part no. Tank model VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 394 Rc 3/8 VBAT20 VBAT20S 305 206 674 180 200 100 400 Rc 1/2 430 Rc 1/2 444 Rc 3/8 VBAT38 VBAT38S 355 256 824 205 250 150 500 Rc 3/4 480 Rc 1/2 14-9-9

(Except L-04 and LL-04 which are for the body of 6 tube.) Swivel type fittings, elbow (L) and (LL) constitute the combination with a male connector (H) and connector as shown in the diagram.

Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)

www.stevenengineering.com I 6.11 VACUUM VACUUM PADS SERIES ZP H O W T O O R D E R ZPT P A D V E R T I C A L T Y P E W I T H O U T B U F F E R ZPT V A C U U M E N T R Y ( A L S O M O U N T I N G T H R E A D D I A) P A D D I A M E T E R S Y M B O L T H R E A D D I A M E T E R 2~ 8 10~ 16 20~ 32 40 50 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 P A D M AT E R I A L Male

A Unused A Unused A Unused A Unused A Unused A B A B A B A B A B A A A B A B A B A A A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 0 0 1 2 3 4 5 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System ADDRESS NO. STATION NO.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

1 E-P HYREG Series VY1 A hybrid regulator is created from a regulator and a solenoid valve F.R.L. AV AU Stepless control through electric signals AF A maximum effective area of 670 mm2 (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 x 30 x 39) and a 3 port, high-capacity exhaust main regulator (Series VEX100).