Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175
Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Indicator light Circuit with Light/Surge Voltage Suppressor DC circuit AC circuit Caution Indicator light Do not apply excessive torque when turning the locking type manual override. (0.1 Nm or less) A() A [+] SOL SOL C(+) C ZNR Indicator light [] No polarity by adopting non-polar light. 4-14-22 23 Base Mounted Series VQZ100/200/300 Precautions Be
Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.
Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Max.
Bore size Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
~ 2200 Setting of OUT1 output set value 2 R/W HYS mode hysteresis S16 200 Y 0 ~ 2400 Setting of OUT1 hysteresis 3 R/W Wind mode lower limit set value S16 1000 Y -200 ~ 2200 Setting of OUT1 output set value (lower limit of window comparator) 4 R/W Wind mode upper limit set value S16 2000 Y -200 ~ 2200 Setting of OUT1 output set value (upper limit of window comparator) 1240 0X04D8 5 R/W Wind
Note 2) Flange configuration is exclusive to SMC. 1 1/2B 120 2B 200 2 1/2B 315 3B 450 Description Part no.
Note) 200 V type only. 400 V type is provided with an earth leakage breaker as standard.
Solenoid Valve for 200 V, 220 VAC Specifications Manual Override Operation Warning Warning Solenoid valves with grommet and L/M type plug connector AC specifications have a built-in rectifier circuit in the pilot section to operate the DC coil. With 200 V, 220 VAC specification pilot valves, this built-in rectifier generates heat when energized.
400 300 200 100 0 VF B VFR VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VZS C VFS VS4 800 700 600 500 400 300 200 100 0 VQ7 D EVS VFN 800 700 600 500 400 300 200 100 0 E It is when the cylinder is extending that is meter-out
For servo amplifier of 200 to 7kW, built-in regenerative resistor is used.
, 250, 300, 350, 400, 450, 500 1000 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175
V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option) CH1 0.1 15 to 25 HRL Inverter dual type 26 kW Indoor use 19 kW 9 kW CH2 0.5 20 to 40 1.0 kW (Max. 1.5 kW) 322 Circulating Fluid Temperature Controller Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series
C3: 3.2 (SMC) C4: 4 (SMC) C6: 6 (SMC) N1: 1/8" (SMC) N3: 5/32" (SMC) N7: 1/4" (SMC) L: DIN Rail Overall Length n: Stations L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 L2 L3 L4 L5 148 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 135.5 137.5 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 125 112.7 123.2
R port P, E port D: Push-turn locking slotted type Port size Electrical entry Nil: Without sub-plate 24, 12, 6, 5, 3 VDC M8 connector 24, 12, 6, 5, 3 VDC 100, 110, 200, 220 VAC Grommet L plug connector M plug connector 24, 12 VDC 100, 110, 200, 220 VAC DIN terminal G: Lead wire length 300 mm L: With lead wire (Length 300 mm) D, Y: With connector WO: Without connector cable MN: Without lead
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
0.5 1000 1000 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 200 200 100 100 40 32 30 40 50 30 40 50 25 40 20 32 Load weight: m (kg) Load weight: m (kg) 20 20 [Example] 25 10 10 20 5 4 5 4 3 3 2 2 1 1 0.5 0.5 100 500 400 300 200 100 500 400 300 200 1000 1000 Maximum speed: V(mm/s) Maximum speed: V (mm/s) Graph 7 Graph 4 0.5MPaP 0.5MPaP 200 200
410 490 33 46 140 170 439 519 440 520 200 260 Precautions Be sure to read before handling.
300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Ex. 1) To detect 300 m, select a 1.0 detection nozzle and supply pressure of 0.2 MPa.
Standard Stroke Bore size (mm) Standard stroke (mm) 20 20, 30, 50, 100, 150, 200 25 20, 30, 50, 100, 150, 200 32 25, 50, 100, 150, 200 40 25, 50, 100, 150, 200 50 25, 50, 100, 150, 200 63 25, 50, 100, 150, 200 Manufacture of Intermediate Stroke Intermediate strokes of 1 mm each can be produced by using spacers with standard stroke cylinders.