(a) LECSSAlways remove the wiring from across P-D and fit the regenerative option across P-C. The G3 and G4 terminals act as a thermal sensor. G3-G4 is disconnected when the regenerative option overheats abnormally. Always remove the lead from across P-D. Driver Servo amplifier Regenerative option P P C C G3 D (Note 2) G4 5m max. (Note 1) Cooling fan Note1.
5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e q w e q w (A) 4 (B) 2 (A) 4 (B) 2 VQC4200 VQC4201 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e q w r e q w r (A) 4 (B) 2 (A) 4 (B) 2 VQC4300 VQC4301 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 (A) 4 (B) 2 VQC4400 VQC4401 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 (A) 4 (B) 2 VQC4500 VQC4501 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Component
three phase 200 VAC CNP1 NFB MC CNP1 NFB MC L1 L1 Single phase 200 to 230 VAC Three phase 200 to 230 VAC CNP3 CNP3 L2 L2 U U U Motor U Motor L3 L3 V V V V M M N N() W W W W P1 P1 PE PE P2 P2 CNP2 CNP2 P P(+) Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and L2 terminals
P Cable length is selectable from 1 m, 3 m and 5 m. P Improvement in the maximum operating temperature from 40C to 50C (Actuator unit only) P Mounting method can be selected among 3 types.
Load mass m [kg] Load mass m [kg] 7 7 6 6 5 5 4 4 V = 200 V = 200 3 3 2 2 V = 300 1 1 V = 300 0 0 20 40 60 80 100 120 140 160 180 200 0 0 50 100 150 200 250 300 L3: Overhang Allowable range: 200 mm L3: Overhang Allowable range: 300 mm Allowable overhang L [mm] Allowable overhang L [mm] 170 MXQ Series Determine the overhang.
(mm) Bore size (mm) Stroke range (mm) AL AK AP AJ AI AH AG N AB M AA L K J I V B U T A O P S 63 80 100 12 14 60 180 158 250 228 100 25 66 25 180 135 117 65 108 228 192 30 M12 x 1.75 depth 23 Rc 1/4 200 72 75, 100, 125 150, 200, 250 300 16 14 70 200 178 284 262 115 27 76 30 214 160 138 75 128 262 224 M12 x 1.75 depth 28 Rc 3/8 35 230 89 16 16 80 226 200 326 300 125 30 80 32 245 190 153 85
Note 2) Flange configuration is exclusive to SMC. 1 1/2B 120 2B 200 2 1/2B 315 3B 450 Description Part no.
X530 40 1.5 159 150 100 96 29 22 28 70 86 49 3 55000 9.1 200 JAF200-45-150-X530 45 1.5 159 150 100 96 29 22 28 70 86 49 3 55000 9.2 Foot Type: JAL JAL180 200--X530 F R K M Center of sphere E 4 x J U U D T C 60 G P A H L B Dimensions (mm) Maximum operating tensile and compressive force (N) Center of Maximum screw-in depth P Allowable eccentricity U Applicable bore size Model M A B C D E F
With control unit Centralized wiring/Supply port left Individual wiring/Supply port right Centralized wiring air catch sensor ISA2-HE41P Terminal box Individual wiring air catch sensor 2 port solenoid valve 2 port solenoid valve ISA2-GE41 Regulator 3 0 3 0 3 0 3 0 3 0 3 0 Supply port Supply port P P P P P P T T T T T T U U U U U U E E E E E E L L L L L L S S S L L L S S S L L L 6 9 6 9 6
200 100 1 2 3 4 5 10 20 30 1002 3 4 5 10 20 30 0.5 40 50 100 Load weight (kg) Load weight (kg) 20 Horizontal collision: P = 0.5 MPa 40 Horizontal collision: P = 0.5 MPa 2000 1500 2000 1500 Collision speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg)
Secure the adjusting bolt at the position where it protrudes approximately 0.5 mm from the shock absorber. 25 Horizontal collision: P = 0.5 MPa 50 Horizontal collision: P = 0.5 MPa 2000 1500 2000 1500 Collision speed (mm/s) Collision speed (mm/s) L unit L unit 1000 1000 Air cushion Air cushion 500 400 300 500 400 300 Adjusting bolt 200 200 1002 3 5 10 20 50 100 1 2 3 4 5 10 20 30 0.5 40 50
200/230VAC Note) Refer to pages starting with 205 for driver dimensions.
= 0.5MPa For 40 Horizontal impact: P = 0.5MPa 2000 1500 2000 1500 Impact speed (mm/s) Impact speed (mm/s) L-unit 1000 1000 Air cushion 500 400 300 500 400 300 L-unit Air cushion 200 200 Caution 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 1.
VXK21 VXK22 VXK23 Model Solenoid Coil P P P 2 mm P P P P P P P P Coil: Class B, Class H Orifice size Orifice size 3 mm 4.5 mm Rated Voltage 6 mm AC: 100 V, 200 V, 110 V, 220 V, 240 V 230 V, 48 V DC: 24 V, 12 V 8 mm Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 Normally Open (N.O.)
L Series VQ1000 Plug lead Cassette Plug-in P.1.10-12 P.1.10-14 Series VQ0 P.1.10-44 P.1.10-36 P.1.10-40 Series VQ1000 P.1.10-36 P.1.10-40 P.1.10-44 C Series VQ2000 P.1.10-40 P.1.10-44 P.1.10-36 Series VQ1000 P.1.10-74 P.1.10-76 P.1.10-78 1.10-4 Manifold Variations C S L Port size SUP EXH port Cylinder port kit kit SY Lead wire Direct electrical entry style Serial transmission unit P, R A,
less No Z80 IC circuit P P Y59A Y69A P p P 3 wire (NPN) IC circuit 5V 12V Y7P Y7PV P p P 3 wire (PNP) IC circuit Y59B 12V Y69B P p P 2 wire Y7NW Y7NWV P p P 3 wire (NPN) 5V 12V Diagnostic indication (2 color indicator) IC circuit Y7PW Y7PWV P p P 3 wire (PNP) Relay, PLC Grommet Solid state switch Yes 24V Y7BW Y7BWV P p P Water resistant (2 color indicator) Y7BA p P 2 wire 12V P5DW Magnetic
P. 192 Refrigerator P. 192 Relay P. 198 Relief valve P. 195 RS232C P. 198 RS485 P. 198 RTD (Resistance Temperature Detector) P. 196 S Sealing mechanism P. 194 SEMI F47 P. 199 SEMI S2 P. 199 SEMI S8 P. 199 Signal input/output, I/O P. 199 Solenoid valve P. 195 Solid state relay (SSR) P. 198 Specific heat/Specific heat capacity P. 195 Specific resistance P. 195 Specified CFC P. 192 SV P. 196
Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.