D Note 1) C Note 2) Note 1) Except double (latching) Note 1) The function symbol is D for double solenoid specifications.

Model Order no. d: Thread nominal size d: Thread nominal size H H B C B C JA6-3-050 JA10-4-070 JA15-5-080 JA15-6-100 JA20-8-100 JA20-8-125 JA32-10-100 JA30-10-125 JA25-10-150 JA40-12-125 JA40-12-150 JA40-12-175 JA40-14-150 JA50-16-150 JAH40-16-150 JA63-16-200 JA63-18-150 JAH50-20-150 JA80-20-250 JA80-22-150 JAH63-24-150 JAH63-24-200 JA100-24-300 JA100-26-150 JA100-27-150 JA125-27-200 JA140

port Rc1/8 Dimensions/With DIN rail Station L1 L2 L3 2 70 105 140 3 105 140 175 4 140 175 210 5 175 210 245 6 210 245 280 3.8-6 ISA Guide for Use/Design Data When designing a pneumatic circuit with an Air-Catch Sensor, please refer to the data below.

Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

] The distance of switch ON [mm] The distance of switch ON [mm] 0.25 mm 0.05 mm 0.5 mm 0.05 0.25 0.50 0.04 0.20 0.40 0.15 mm 0.3 mm 0.03 mm 0.03 0.15 0.30 0.02 0.10 0.20 0.01 mm 0.01 0.05 0.10 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 10 ISA3 Series Response Time

BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.

, 200, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250

The D-A9l/M9l/P3DWAl auto switches are shipped together, but not assembled.

Standard Stroke DMaximum manufacturable stroke Bore size (mm) -X Standard stroke (mm) 20700 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 800 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Data 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

LPush-locking slotted style [D] While pressing, turn in the direction of the arrow. If you do not turn, the mechanism does not lock in position.

1 n 69.3 (Max. 78.4) 60 OUT OUT OUT OUT OUT OUT 19.5 4 11.6 Detection port Rc 1/8 Dimensions: With DIN rail 3 105 140 175 4 140 175 210 5 175 210 245 6 210 245 280 2 70 105 140 Station L1 L2 L3 819 Series ISA Operation guideline: Design data When you design the pneumatic circuit using the air catch sensor, please refer to the data below.

Distance from the ionizer to the neutralized workpiece (mm) IZS40/41 IZS42 With air purge With air purge Ion generation frequency (Hz) Without air purge Without air purge High speed static neutralization cartridge 0.1 100 to 175 50 to 1300 50 to 2000 50 to 2000 0.5 100 to 175 50 to 1300 50 to 2000 50 to 2000 1 300 to 500 300 to 1500 400 to 2000 600 to 2000 100 to 175 50 to 1300 50 to 2000

Page 175 Required Cooling Capacity Calculation . Page 184 List of Function . Page 175 Precautions on Cooling Capacity Calculation ... Page 185 Alarm . Page 175 Circulating Fluid Typical Physical Property Values ... Page 185 Communication Function . Page 176 Specific Product Precautions . Page 186 Options With Caster Adjuster-foot . Page 177 With Earth Leakage Breaker .

D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style .