Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -,
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting
Applicable model : D-A93V
l 175 32 173 + l 151 197 + l 201 40 193 + l 173 221 + l 234 50 222 + l 202 254 + l 244 63 227 + l 207 264 + l 310.5 80 261 + l 252 319.5 + l 336.5 100 269 + l 260 345.5 + l ( ): Denotes the dimensions for long stroke.
Volume GR-L-005 5 g GR-L-010 10 g GR-L-150 150 g 3. Do not wipe off grease from the sliding part of the air cylinder.
M6 x 80 L M10 x 100 L M5 x 55 L 65 80 100 55 CL1 -15D -15D x 70 L x 85 L x 105 L x 60 L 70 85 105 60 -20D -20D x 75 L x 90 L x 110 L x 65 L 75 90 110 65 MLGC -25D -25D x 80 L x 95 L x 115 L x 70 L 80 95 115 70 -30D -30D x 85 L x 100 L x 120 L x 75 L 85 100 120 75 10.5 CNG -35D -35D 7 12.5 17 x 90 L x 105 L x 125 L x 80 L 90 105 125 80 -40D -40D x 95 L x 110 L x 130 L x 85 L 95 110 130 85
cap screw (M2.5 x 6 L, M2.5 x 9.5 L). the auto switch firmly with the hexagon socket head cap screw (M2.5 x 5 L, M3 x 14 L).
RD MM MM 30 DA MM 30 DB DB T A H A T C B A H A L K H W H Symbol: A27 Symbol: A26 Symbol: A25 Symbol: A24 DA 30 MM DA 30 MM MM MM AL H LB K A L A H AL H AL L K H Symbol: A30 Symbol: A29 Symbol: A28 DA 30 30 MM 30 MM L W W A L H A T AL A H Auto Switch Made to Order T MM H 118 C85/C75 Series Made to Order Please contact SMC for detailed dimensions, specifications, and lead times.
H H L L Gripping point Gripping point Gripping point L and H are appropriate L is too long H is too long 5. Attachment should be designed as light and short as possible. 1) A long or heavy attachment increases the inertia force to open or close the fingers.
Select the graph that corresponds to the imaginary stroke l. k Imaginary stroke l = (Stroke) + k + l k: Distance between the center and end of the plate (Example) q When using CXSJM6-10 and l = 15 mm: Imaginary stroke l = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30n). 6 2.75 mm 10 4 mm 15 5 mm 20 w When using CXSJL25-50 and l =
L RR,IU1 E, A, L, t MM NX Part no A2 NDHIO boreSlzc D
f C B h + l A K N N H F F ZZ + l + 2 x strokes S + Stroke H + Stroke ZZ + 2 x strokes V W Cushion valve Port 4 x J G G 2 x P (Rc, NPT, G) M Width across flats KA Width across flats KA MM MM With rod boot (Both sides) E E D D e e C B l + Stroke l AL AL C B f f A K N N A K h + l h + l + Stroke S + Stroke ZZ + 2 x l + 2 x strokes (mm) Bore size (mm) Stroke range (mm) P S N MM M K KA W V J G