SMC Corporation of America
Elite Part Number Search
Search Results "CDPX2H15-200-J79LS"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 60mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -

Magnet: Built-in, Mounting: Rod Flange, Bore: 16mm, Stroke: 60mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting: Rail Mounting, Cushion: Air Cushion, Series: -

Magnet: Built-in Magnet, Series: -, Mounting: Front Flange, Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting Type: Rail Mounting

Magnet: Built-in Magnet, Series: -, Mounting: Basic, Bore Size: 10mm, Stroke: 15mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting Type: Rail Mounting

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber,

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Stroke: 5mm, Option: Standard (Rod End Female Thread), Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: Adjustable Stroke, Extension Type, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Stroke: 25mm, Option: Standard (Rod End Female Thread), Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., X Option: Adjustable Stroke, Extension Type, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Through Hole [Standard], Bore Size: Ø50 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Rubber Bumper, Rod End Male Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: 1 pc.

Magnet: Built-in, Mounting: Through Hole [Standard], Bore Size: Ø50 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Rubber Bumper, Rod End Male Thread, Lock Position: Front Lock, Release of Manual: Locking, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: 1 pc.

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, NC, 50MM CE1 OTHERS (COMBO), 8.06523 lb

The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.Stroke reading cylinder with position feedback, Resolution: 0.1mm, Water resistance improved by changing sensor unit filter, Power supply

This is a legacy product. Please contact us for the latest version.sales@ocaire.com