SMC Corporation of America
Elite Part Number Search
Search Results "CDNGTA32-400-D-M9PWSDPC-C"

A B C D Switch Internal Circuit Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

D side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) 3 m 2-5-11 Base Mounted 12 Series VQ4000 Kit (D-sub connector kit) F Applicable connector: D-sub connector (25P) (Conforming to MIL-C-24308) 70 38 2-Rc 1/8 (Pilot EXH port) 18 18 17.5 PE 30 42 R2 R1 P 1 3 5 2n-Rc 1/4, 3/8, C8, C10, C12 4(A), 2(B) port SMC 6-Rc 1/2 Rc 1/4: Rc 1/4 thread 1(P), 5(R1), 3(R2) port

It is already built into the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal (Type D) DC specifications of type D and DO are only available with 12 and 24 VDC. Power saving circuit is not available for D or DO types.

Applicable bore size (mm) D B1 C d H1 Part no.

Applicable bore size (mm) D B1 C d H1 Part no.

side LER w LEFG32 (L = 30 mm) Displacement [mm] 0.06 LEFG25 (L = 25 mm) D side LEH LEFG16 (L = 20 mm) 0.04 LEY -X5 Model Traveling parallelism [mm] (Every 300 mm) LEFG40 (L = 37 mm) q C side traveling parallelism to A side w D side traveling parallelism to B side 11LEFS 0.02 LEFG16 0.05 0.03 LEFG25 0.05 0.03 11LEJS LEFG32 0.05 0.03 0 0 100 200 300 400 500 25ALEFG40 0.05 0.03 Load W [N] Note

Part no. l Applicable snap ring t m 16.2 20.2 36.2 1.5 1.55 1.55 0.9 1.15 1.15 Type C 8 for axis Type C 10 for axis Type C 10 for axis IY-G02 IY-G03 IY-G04 CD-G02 CD-G25 CD-G03 CD-G04 Type C 8 for axis Type C 10 for axis Type C 12 for axis Type C 14 for axis 38.6 42.6 54 65 1.5 1.55 1.55 2.05 0.9 1.15 1.15 1.15 9-2-34

The set value will start flashing. c. Press the "UP"and "DOWN"buttons to change the set value. c. Press the "UP"and "DOWN"buttons to change the set value. d. Press the "SET"button. d. Press the "SET"button. The set value will light up. The set value will light up. * When the set value is flashing, it is not registered. * When the set value is flashing, it is not registered.

VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177

B A (mm) Applicable auto switch D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV D-F79F Other than the models listed in How to Order, the following auto switches are applicable. For detailed specifications, refer to page 1627.

mm) Applicable bore size (mm) D C d D C Part No.

M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13

11 15 3.5 5.5 142 157 32 31f8 7.5 M14 x 1.5 18 15 M30 x 1.5 1/8 18.5 87 13 20 3 4 160 179 40 34f8 7.5 M16 x 1.5 22 21 M33 x 2 1/4 22.5 108 16 20 5 0 182 205 9 Hydraulic Cylinder: 7MPa Series CHN Accessories (Standard) Rod end nut Material: Carbon steel Mounting nut Material: Carbon steel 30 30 d d C D C D H B H B Part no. d H B C D Applicable bore size (mm) Part no. d H B C D Applicable

Size Order no. 25 LE-D-6-2 14 32 LE-D-6-3 40 LE-D-6-4 -12- 3. Product Outline 3.1 System construction Refer to the Driver operation manual for system construction. 4.Elictric actuators / Common precautions 4.1 Wiring/Cables Warning 1. Adjustment, installation, inspection, or wiring changes should be conducted after the power supply to this product has been turned off.

Retraction End E1 D E H H F G B J C A K MXQ-BT20(L) MXQ-BT25(L) MXQ-BT8(L) MXQ-BT12(L) MXQ-BT16(L) (mm) Stroke adjustment range (mm) Applicable size A B C E1 G H J K 1) E D F Model MXQ8(L) MXQ-BT8(L) M8 x 1 M3 x 8 5 40.8 14 12.5 1.4 24.5 12 20 23 8 MXQ12(L) MXQ-BT12(L) M8 x 1 M4 x 10 6 40.8 16 16 1.4 29 12 18 28 10 MXQ16(L) MXQ-BT16(L) M10 x 1 M5 x 12 7 46.7 17 20 1.4 35.5 14 22 33.5 12 MXQ20

D-F5BAL/F59F D-F5W/J59W CP95 ~ = NCM ~ = ~ = NCA D-X 20Proper Auto Switch Mounting Position Auto Switch Mounting Height Data D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Auto switch model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A59W D-F5NTL Bore size (mm) A B A B A B A B Hs Hs Hs Ht Hs Ht 74.5 125 0 0 2 2 4.5 4.5 9.5

C type 22 for shaft 13 Accessary Dimensions Series CG5-S Accessory Dimensions Rod end nut Clevis pin Material: SUS440 (pin) SUS304 (snap ring) Material: SUS304 30 d d Dd9 D C t m t l m L H1 B1 Metric (mm) (mm) Part no.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-9 Connection of RS-232C 3.3 Installation HRR Series 3-18 HRX-OM-X084 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa

Magnet: D (Built-in), Mounting: T (Rear Trunnion), Cushion: A (Non-lube Air Cushion), Bore Size: 32mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None