Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Magnet: Built-in Magnet, Mounting: Rod Trunnion, Bore: 20mm, Stroke: 25mm, Action: Single Acting, Spring Return, Rod End Thread: Male Rod End, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 20mm, Port Thread: Rc, Stroke: 150mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: Nylon Tarpaulin, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 20mm, Port Thread: Rc, Stroke: 125mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: Nylon Tarpaulin, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 20mm, Port Thread: Rc, Stroke: 200mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -
pressure Fluid Vacuum of inert gas Operating temperature oC 5 to 150 Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1 14 45 Leakage Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperature, excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperature, excluding gas permeation Flange type KF(NW
25 50 123 48 1 12 40 26 41 16 7.5 XLD-40 65 170 66 2 11 55 41 63 20 15 XLD-50 70 183 79 2 11 75 52 68 20 17.5 XLD-63 88 217 100 3 11 87 95 70 72 20 20 XLD-80 90 256 117 3 11 114 110 83 98 20 26.5 XLD-100 108 321 154 3 11 134 130 102 133 20 38 XLD-160 138 335 200 3 11 190 180 153 114 30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW
Fluid Vacuum of inert gas Operating temperature oC 5 to 150 Operating pressure Pa Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1) 5 14 45 80 Internal 1.3 x 10-10 for the standard material (FKM) Leakage at ambient temperatures , excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW