SMC Corporation of America
Elite Part Number Search
Search Results "CDM2RA32-300Z-A93L"

Magnet: D (Built-in Magnet), Type: Pneumatic, Mounting Style: A (Bottom Mounting Style), Bore: 32mm, Stroke: 25mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Type: Pneumatic, Mounting Style: A (Bottom Mounting Style), Bore: 32mm, Stroke: 100mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Type: Pneumatic, Mounting Style: A (Bottom Mounting Style), Bore: 32mm, Stroke: 150mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Type: Pneumatic, Mounting Style: A (Bottom Mounting Style), Bore: 32mm, Stroke: 75mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in, Style: Air Pressure Style, Mounting: Bottom Mounting, Bore Size: Ø32, Stroke: 125mm, Cushion: Rubber Bumper, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Style: Air Pressure Style, Mounting: Bottom Mounting, Bore Size: Ø32, Stroke: 100mm, Cushion: Rubber Bumper, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Style: Air Pressure Style, Mounting: Bottom Mounting, Bore Size: Ø32, Stroke: 50mm, Cushion: Rubber Bumper, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Style: Air Pressure Style, Mounting: Bottom Mounting, Bore Size: Ø32, Stroke: 25mm, Cushion: Air Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

Magnet: D (Built-in Magnet), Cushion Type: A (Air Cushion), Bore Size: 63mm, Stroke: 300mm, Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Cushion Type: A (Air Cushion), Bore Size: 50mm, Stroke: 300mm, Thread: Male Rod End, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 32mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 300mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: L (3m)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Type: A (Air Cushion), Bore: 32mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 300mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: L (3m)