Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P 2-wire 12 V M9BV M9B 3-wire (NPN) 5 V, 12 V M9NWV M9NW IC circuit 3-wire (PNP) M9PWV M9PW

Indicator light Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Wiring (Output) Type Special function Electrical entry M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid

Vertical Horizontal l : Load eccentricity m Mounting orientation m L L Up to 100 Up to 300 Up to 500 Up to 100 Up to 300 Up to 500 Maximum speed (mm/s) 50 (4) 200 (6) 50 (7) 200 (9) 50 (10) 200 (12) (2) 100 (5) 100 (8) 100 (11) Load eccentricity (l mm) (1) (3) Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also

Nil Without auto switch B Basic L Axial foot F Rod flange G Head flange C Single clevis D Double clevis T Center trunnion * For applicable auto switches, refer to the table below.

Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

Vertical Horizontal l : Load eccentricity m Mounting orientation m L L Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Up to 300 Up to 100 Up to 500 Up to 100 Up to 300 Up to 500 Maximum speed (mm/s) (2) 50 (7) 100 (5) 50 (4) 100 (8) 200 (9) 100 (11) 50 (10) (1)

Mechanically Jointed Rodless Cylinder Cam Follower Guide Type Series MY2C 16, 25, 40 How to Order M9BW MY2C Cam Follower Guide Type G L 16 300 Made to Order Refer to page 1099 for details. Guide type C Cam follower guide Number of auto switches Bore size 16 25 40 16 mm 25 mm 40 mm 2 pcs. 1 pc. n pcs.

Hydraulic Cylinder 20, 25, 32, 40 CHN Series 7 MPa CHQ How to Order CHK CHN CHN CHN 25 100 M9BW L C CHM Auto switch mounting bracket Note) Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.) Applicable to 20 only.

Mechanically Jointed Rodless Cylinder with Protective Cover Slide Bearing Guide Type, Cam Follower Guide Type MY1W Series 16, 20, 25, 32, 40, 50, 63 How to Order MY1 M W K 300 M9BW 32 Guide type M C Slide bearing guide type Cam follower guide type Auto switch Nil Without auto switch (Built-in magnet) With protective cover Applicable auto switches vary depending on the bore size.

C dimension is 77 mm. Part no.: MGPM20-39Z-XB10 Special body manufactured for 39 stroke. C dimension is 76 mm.

, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80: 1400 100: 1500 Refer to pages 19 to 23 for cylinders with auto switches. 80, 100 Intermediate strokes not listed above are produced upon receipt of order.

j A AulO switch o o c: C' iii' JJ o Q, .J!

Auto switch mounting surface Bore size (mm) 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side A, B, C sides A, B, C sides Port, A, B, C sides BQ-2 BQ2-012 Two kinds of auto switch mounting brackets are used as a set.

28 6 Width across flats 10 (4 locations) 24 46 K (70) 30 24 24 Closed E 12.5 12.5 30 Open F 17 17 54 G 4 x M6 x 1 through (Thread for mounting attachment) Model A B C D E F G H J MHL2-20DZ 54 58 71 38 82 122 160 32 120 MHL2-20D1Z 96 100 113 80 142 222 260 68 195 MHL2-20D2Z 116 120 133 100 162 262 300 88 235 J dimension is at fully closed.

Double clevis: Clevis pins, type C snap ring for axis, and Body mounting bolts.

A AA C J L L J K (4 locations) Flat washer With 4 pcs.

Vacuum port pressure range: 101 kPa to 0.6 MPa 1249 Free Mount Cylinder for Vacuum Series ZCUK How to Order C 16 ZCUK D 20 With auto switch C D 16 D 20 ZC UK M9BW Number of auto switches Built-in magnet Auto switch Acting D Double acting 2 pcs. 1 pc.

Mounting Bolt for CQM/Without Auto Switch Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt CQMB12-5 -10 -15 -20 -25 -30 CQMB16-5 -10 -15 -20 -25 -30 CQMB20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 CQMB40-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -75 -100 CQMB50-10 -15 -20 -25 -30 -35 -40 -45 -50 -75 -100 CQMB25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 CQMB32-5 -10 -15 -20 -25