c, d, e) BMA3-040S (A set of b, c, d, e) BMA3-050S (A set of b, c, d, e) BMA3-063S (A set of b, c, d, e) RZQ Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch a e White (PBT) b Switch holder d Auto switch mounting screw c Auto switch mounting band * Band (c) is mounted so that the projected part is on the internal side (contact side with the tube).
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Standard Stroke Bore size (mm) Standard stroke (mm) 25, 50, 75, 100, 125, 150, 175, 200, 250, 32 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, 40 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, 50 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, 80 300, 350
E 300 L 03 D L-shaped piping adapter q w e q Body size [Applicable AC size] 200 [AC20] 300 [AC30] 400 [AC40] 500 [AC40-06] 600 Symbol Description [AC50, AC60] w Pipe thread type Nil Rc V V V V V N NPT V V V V V F G V V V V V + 01 1/8 V V 02 1/4 V V V 03 3/8 V V 04 1/2 V V V e Port size Port size 06 3/4 V V 10 1 V Standard Specifications Fluid Air Ambient and fluid temperatures 5
Description Mat'l Material Part No. 200 125 140 160 180 250 300 Rod cover Balck coated Rolled steel plate Lube style Head cover Black coated Rolled steel plate 125 to 160 Hard anodized Aluminum alloy @3 Wiper ring SDR-36 SDR-36 SDR-40 SDR-45 SDR-50 SDR-60 SDR-70 125 to 300 Cylinder tube e Carbon steel pipe Inside: Hard chrome plated PCS-85(R) @4 Cushion seal DSM-50S DSM-50S DSM-50S DSM-60S
B 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.34 0.20 4-E 0.34 0.25 0.50 0.25 0.50 0.34 0.53 0.34 0.66 0.41 B Rear screw clearance hole / NC(D)Q8M(Z) (Inch) Symbol Bore E B 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.34 0.20 4-E 4-E 0.34 0.25 0.50 0.25 0.50 0.34 0.53 0.34 0.66 0.41 B Through screw clearance hole / NC(D)Q8N(Z) (Inch
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewied Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewied Connector: L (3m)
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A59W--Reed, DC Volt >5<24, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Dryer A G F E D C B B 7kVA IDF120D 360 30 11 300 260 400 540 IDF-TR7000-8 94 Three phase compound 9kVA IDF150D 400 40 13 350 300 450 650 IDF-TR9000-8 109 220, 240, 380, 400, 415, 440V (50/60Hz) 200V (50/60Hz) 11kVA IDF190D 550 60 13 400 350 600 450 IDF-TR11000-8 131 4-F A 13kVA IDF240D 400 60 13 350 300 450 600 IDF-TR13000-8 138 D 18kVA IDF370B 400 40 13 350 300 450 650 IDF-TR18000-8 179
Standard stroke (mm) Max. stroke without switch (mm) Max. stroke with switch (mm) Bore size (mm) Symbol Specifications 300 300 6 50, 100, 150, 200 -X116 -X160 -X322 -X1468 Hydro specifications 500 500 10 50, 100, 150, 200, 250, 300 High speed specifications 50, 100, 150, 200, 250, 300 350, 400, 450, 500 Outside of cylinder tube with hard chrome plating 15 1000 750 Interchangeable specification
Example) With L type bracket: E 0LWith T type bracket: E 0TOne with AC installed is special product. T Type Interface: (T) 1/8, 1/4, 3/8 T type interface makes it easier to diverge air output.