D-A90V, D-A93V, D-A96V Note) A contact protection box should be used in any of the following conditions to prevent the shortening of the working life of the switch.

All three series, VQ, SX and SY, are c o m p a c t , l i g h t w e i g h t a n d a e s t h e t i c i n a p p e a r a n c e .

, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)

Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.

Applicable models: D-A93, D-A93V, D-Z73 1) Even if connections are reversed on a 2-wire type switch, the switch will not be damaged because it is protected by a protection circuit, but it will remain in a normally on state. However, it is still necessary to avoid reversed connections since the switch will be damaged if a load short circuits in this condition.

D-F9 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 Switch Hysteresis D-F9W 6 15 19 41 46 43.5 Proper auto switch mounting positions (Series CEP1 ) (mm) Bore size (mm) 12 Auto switch model Symbol 20 A B A B A B A B A B A B A B 75.2 82 Switch operating position (ON) D-A90, A93, A96 7.9 12 75.2 82 D-A90V, A93V, A96V 7.9 12 Hysteresis Reed switch: 2mm or less Solid state switch: 1mm or less 79.2 86

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S

When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

A + A' A' w After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved. A A' A' e When air is supplied for the piston extension, the check valve opens and the piston extends with no delay.

Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z M 1.4 100 x a x mn x g 1 3 a a ME x FE x Z Dynamic moment ME Dynamic moment ME does not occur. 1 3 mn x g ME M3 ME x FE x Y mn x g ME FE FE Note) Regardless of the mounting

For the angle adjusting type, angle adjusting screws are mounted to the left cover. of e g k n e ra y w n a io y Angle adjusting screw Angle adjusting screw at 1 ot 8 0 n R io ct e r di g in st u dj n A o a n ti g c e e l e gl ir d a n d g A j u n s ti ti s n u g j d a d ir e e R R l g c 0 0 n ti ot ot o A 8 8 n 1 1 at at y y io io a a n n w w r r y y a a e e n n k k g g of of e e Angle

Applicable models : D-93, A93V 1) If connections are reversed on a 2-wire type auto switch, the auto switch will not be damaged if protected by a protection circuit, but the auto switch will always stay in an ON state.

When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

If driving a load such as a relay that generates a surge voltage, use a contact protection box. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly.

watch maker's screwdriver with a grip diameter of 5 to 6mm.

However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12

Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.

Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.