8 @1 @2 w !4 !2 !5 t @0 @3 @4 @5 !9 !8 @1 @2 @6 !4 !2 !3 y !0 !1 e q @8!6 u !7 o i !3 y !0 !1 @7 r q @8 !6 u !7 o i CXSJM10 CXSJL10 @9 !7 o i !6 r !9 !8 @2 @9 !7 o i !6 @4 @5 !8 r !9 @2 Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Parts List: Standard Piping No. Description Material No.
YA-03 Joint YU-03 RS W M V T2 Joint Part No. 2-D through 2-O counterbore T1 B E J Applicable mounting bracket Bore size (mm) Weight (g) Joint part no.
8 @1 @2 w !4 !2 !5 t @0 @3 @4 @5 !9 !8 @1 @2 @6 !4 !2 !3 y !0 !1 e q @8!6 u !7 o i !3 y !0 !1 @7 r q @8 !6 u !7 o i CXSJM10 CXSJL10 @9 !7 o i !6 r !9 !8 @2 @9 !7 o i !6 @4 @5 !8 r !9 @2 Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Parts List: Standard Piping No. Description Material No.
Cushion valve G 2 x Rc P W V Port G E Width across flats KA TX D E B C H1 AL MM MB MA N 2 x 4 x J N TY B C Width across flats B1 A H K F TT ZZ + Stroke S + Stroke With rod boot d e 10.2 10.2 f h l [mm] Bore size [mm] A AL B B1 C D E F G H H1 J K KA MA MB MM N P S TT TX TY V W ZZ 32 22 19.5 46 17 32.5 12 30 13 13 47 6 M6 x 1 6 10 16 4 M10 x 1.25 27 1/8 84 17 48 49 4 6.5 135 40 30 27 52 22
(Table clearance is included.) 8 Electric Actuator/High Rigidity Slider Type Ball Screw Drive AC Servo Motor (100/200 W) Series LEJS RoHS How to Order LEJS 40 500 A S2 Motor type 1 Size Lead [mm] 40 63 A B LEJS40 LEJS63 Symbol Output Compatible Symbol Type Actuator drivers 2 [W] size 16 20 10 AC servo motor 8 S2 LECSA;-S1 100 40 (Incremental encoder) Stroke [mm] 3 AC servo motor S3 LECSA
B-1 A-1 B-2 A-2 B-3 A-3 Cable color Signal Nil 2 1 6 5 3 4 A A B B COM-A/COM COM-B/ Brown Red Orange Yellow Green Blue S Standard cable Cable color Connector D terminal no. Shield 12 13 7 6 9 8 3 Brown Black Red Black Orange Black Vcc GND A A B B B-4 A-4 B-5 A-5 B-6 A-6 Connector B terminal no.
Proper Mounting Position (Detection at Stroke End) and Mounting Height 32, 40, 50, 63 D-M9/D-M9W/D-A9 D-M9V/D-M9WV/D-A9V Hs B W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6)
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 091 130 182 Note) A set of side supports consists of a left support and a right support.
Alarm reset a: Alarm reset manually In the event of an alarm, simply pushing w will revert from the alarm state. b: Alarm reset externally In the event of an alarm, simply inputting an external emergency stop signal for 50 ms or longer will return to the state prior to the alarm.
(Same surface) Hs 22 B A D-A93 24.5 10.5 16.5 50 50 50 D-M9B D-M9BW D-B54 50 50 75 Auto Switch Mounting Position and Its Height Unit: mm 8.5 Auto switch set value and its height 63 7.5 30.5 47 11.5 34.5 47 2 25 50.5 Auto switch Symbol 40 11 23.5 34.5 15 27.5 34.5 5.5 18 38 50 7.5 30.5 40 11.5 34.5 40 2 25 43.5 A B Hs A B Hs A B Hs D-B54 D-A93 Hs B A 33 D-M9B D-M9BW D-B54 12 Note 1) The
Auto switch (mm) Auto switch model D-A90 D-A93 D-M9N D-M9P D-M9B SMC CLS125 MODEL b a a b a b Bore size CLJ2 FREE LOCK CHECK 125 140 160 180 200 250 62 42 58 46 70.5 50.5 66.5 54.5 CLM2 Cylinder With$ Locking Mechanism 70.5 50.5 66.5 54.5 80.5 60.5 76.5 64.5 CLG1 86 66 82 70 102 82 98 86 CL1 Be sure to confirm operation after mounting.
With air cushion 15 LH B 4 x LD Z Y X W LZ LX 2 x LC (Knock pin position) ZZ + S Stroke LS + Stroke Y X W M (mm) B 54.5 78 LS 54 LX 71 LZ 4 M 10 W 4 LC 7 LD 30 LH 3 LT 16.5 X 8.5 Y Z 63.5 205 ZZ Bore size 40 50 63 5 5 10 12 40 45 91 91 4.5 4.5 17.5 17.5 70.5 75.5 66 82 86 106 5 5 22 22 11 13 242 242 82.5 75.5 Other dimensions are the same as basic type.
MTS Air pressure supplied from A operates on both surfaces q and w. (Extension) MY q w A B Piping is concentrated in the head cover. CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Air pressure supplied from B operates on surfaces e.
(RS1H50 : 10mm RS1H63 : 15mm RS1H80 : 18mm) 1410 Heavy Duty Stopper Cylinder Series RSH/RS1H Auto Switch Proper Mounting Position (Detection at Stroke End) Auto switch B A Auto switch proper mounting position (mm) Auto switch models D-M9 D-M9W D-M9AVL RSQ D-M9V D-M9WV D-M9AL D-Z7/Z80 D-Y59/Y7P/Y7W D-Y69/Y7PV D-Y7WV D-Y7BAL RSG A B A B A B A B A B A B Bore size RS 20 32 50 63 80 23 8.5 23
A C B 1) Initial state (0 stroke position) Stroke B Stroke A A C Precautions B 2) Double output When the air pressure is supplied to the A and C ports at the same time, the double output can be obtained in the stroke A range. Caution W W 1. Do not supply air until the cylinder is fixed with the attached bolt. 2.
side B W A Port C MX M MTS B Distance from 0 of gauge dial when guide block is moved to full stroke after body is fixed on a base.
1 t q r e A A B !6 @3 @6 @5 @4 @6 @2 @4 @5 @1 i y u C-C A-A !8 !3 B @7 !2 C w !7 C !5 !0 o Motor option: With lock !3 !1 !2 @0 !9 Component Parts Component Parts No. Description Material Note 1 Body Aluminum alloy Anodized No.
A C B A C B A stroke operation 1) Initial state (0 stroke position) W W A stroke B stroke A stroke 2) Operation When the air pressure is supplied from the A port, the rod operates the A stroke. A Precautions C B A stroke Caution 1. Do not supply air until the cylinder is fixed with the attached bolt. 2.