Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: Built-in, Mounting: Front Flange, Bore Size: Ø25 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5 m Cord Length, M8-3 Pin Connector
Magnet: Built-in, Mounting: Front Flange, Bore Size: Ø25 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø20 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø25 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø32 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø50 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Compact Foot, Bore Size: Ø32 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: -
Magnet: Built-in, Mounting: Through Hole [Standard], Bore Size: Ø32 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3 m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: Ø32 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 5 m, Number: -
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
However, the counter shows only the lower five digits of the actual value since the driver display is five digits. 10STM m 10(STM-4) inch Command remaining distance rn 10-3 degree pulse (Note 2) For the point table method and program method, the point table and program No. currently being executed are displayed.