SMC Corporation of America
Elite Part Number Search
Search Results "AS1200-M3-J"

How to replace the shock absorber 1) Loosen the hexagon socket head set screw (M3) on the piston rod.

(A) (z) Z m x g Examine M3. M3 = m x g x Y = 5.5 x 9.8 x 30/1000 = 1.6 [Nm] 2B = M3/M3max = 1.6/17.0 = 0.10 Refer to [3] Calculation for Overall Center of Gravity in the Y-axis on front matter 7. M3 Find the value of M3max when Va = 200 mm/s from Graph (11) x.

16 0.090 J Minimum Operating Pressure Unit: MPa Bore size (mm) 10 16 Minimum operating pressure 0.03 Standard Strokes Made to Order (For details, refer to pages 1069 to 1262.)

(Panel adaptor A + Panel adaptor B + Mounting bracket) ZS-22-D (With 4 pcs. of M3 tapping screws) ZS-22-E Panel adaptor A ZS-22-03 Panel adaptor B ZS-22-02 Mounting bracket ..

QA Tubing O.D. 6 J QB Q F Built-in One-touch Fittings Stroke 13 20 Stroke 8 Applicable tubing O.D.

G5-S CV MVGQ CC RB J D-X 20Data 10-5-19 19 Series MQM Dimensions Basic style: MQMLB 6 Mounting nut M12 x 1 Rod end nut 2-M5 x 0.8 15 M4 x 0.7 13 4 11 16 15 8 21 4.5 11 66 + Stroke 27.5 93.5 + Stroke 10, 16, 20, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 A F MM F S + Stroke H ZZ + Stroke Bore size (mm) NN A P D MM F G1 G2 S ZZ I H J N1 N2 NA 10 M12 x 1 15 M5 x 0.8 4 M4 x 0.7

MK(2) b) Type B mounting (When using the cylinder tube threads) RS Q G RS H A RZQ MI W S CEP1 CE1 CE2 ML2B E t E t C J G5-S Compatible Mounting Bolt Dimensions CV Model Type A mounting Type B mounting E (mm) D: Bolt length (mm) C (mm) Mounting bolt size Mounting bolt size MVGQ MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D 8 to 11 M3 x

BMU1-025 BQ-1 BQ-2 BQ-1 BQ-2 1 1 1 1 1 M3 x 0.5 x 6L M3 x 0.5 x 8L M3 x 0.5 x 10L M3 x 0.5 M3 x 0.5 1 Auto switch mounting screw D-A7, A8 D-F7, J7 BBA2 Auto switch mounting nut (Square nut) 2 3 Auto switch mounting nut (Convex shape) Note 1) A spacer for BQ-2 (black resin) is not included.

In case of ZQ1 3M-00, the overall length is 111. 5 6 5 6 5 6 5 6 K J Q N K J E F E F Q N Circuit diagram P PE EXH EXH P PE Left Right V V V V E F E F E F 5 6 5 6 5 6 ZQ1 3M-K1 ZQ1 3M-K2 KZQ1 3M-J1 -FZQ1 3M-Q1 K10 Series ZQ Dimensions Manifold type (with PD port) ZZQ1 -BSC ZQ1 3MCommon air pressure supply (P) port (One-touch fitting: Applicable tubing O.D. 8) Supply valve Release valve Common

AS121F-M3-02 AS121F-M3-01 2.4 1/8" 7.2 19.7 26.6 24.1 24 21.5 4 8.4 10.5 M3 x 0.5 5.5 5.2 6 11 24.3 26.8 2 11.4 8.8 M3 x 0.5 16.1 10 12.7 5.5 7.5 6 24.3 21.8 AS121F-M5-02 AS121F-M3-03 3 7 M5 x 0.8 5/32" 9.3 11.5 24.8 27.3 AS121F-M3-23 AS121F-M5-01 3.2 8.4 M5 x 0.8 1/8" 10.5 5.5 7.2 16.1 26.6 24.1 24 21.5 4 19.7 12.7 M3 x 0.5 8.4 22.1 17.3 AS121F-M3-04 AS121F-U10/32-01 4 9.3 1/8" 10 10-32UNF

ExampleRod end nut for JS40 CV MVGQ CC RB J D-X 20Data 10-19-13 14 Series JS Dimensions JS10, 16 Center of sphere M M U D J U F B G H C E P Use the precision spanner for clock 4 mm in the case of mounting male thread of JS10.

ExampleRod end nut for JS40 CV MVGQ CC RB J D-X 20Data 10-19-13 14 Series JS Dimensions JS10, 16 Center of sphere M M U D J U F B G H C E P Use the precision spanner for clock 4 mm in the case of mounting male thread of JS10.

VVQ1000-J-1-A VVQ1000-J-1-B Ejector valve model Nozzle diameter (mm) 0.7 1.0 Max. suction flow rate N (NL/min) 11 20 Note 1) SUP and EXH ports on the ejector unit manifold base are arranged on D-side alone. The end plate on the U-side is the same as that used in the L kit. Note 2) Individual piping is provided for the supply and exhaust ports of the ejector unit.

type 10 C D J 2 W L 16 60 H7B 21 C D J 2 W L 16 60 H7B Number of auto switches 2 pcs. 1 pc. n pcs.

D-G79, D-K79, D-K79C Cover Auto switch mounting screw M3 x 0.5 x 6l Auto switch Auto switch Auto switch Auto switch mounting screw M4 x 0.7 x 22l Auto switch mounting screw M3 x 0.5 x 14l Auto switch mounting band (with bracket) Cylinder tube Auto switch mounting band (with bracket) Auto switch mounting band (with bracket) 1.

switch J E Japanese English The displayed language can be changed to English or Japanese.

Note 3) Bowl assembly for AF30 to 60 models comes with a bowl guard (steel band material). 26 AF10 to 60 Dimensions L AF10, 20 AF50, 60 A G D Bracket (Option) L Bracket (Option) F D M G K K F M J J B E E B H OUT IN C OUT IN H C Port size OUT OUT Port size o s AF10: 25 AF20: 40 Drain A P Min. clearance for maintenance AF30, 40, 40-06 L Bracket (Option) A D G F M K J B E Drain Min. clearance

BOre size ' 1~ A ' Q K B C GB J MM . NN ' A' oD C~ IGA ; H I " 'R J, , SLD (Trol). " ... . I ' . 0.040 6 7 11 17 8 M3 x O.5 I. 16.5 10.5 6 B M10 X1.0 9 3 7 3 , 065 '10 . , jj:!'

Coordinates and Moments z M3: Yawing M1: Pitching y x M2: Rolling Static moment Ceiling mounting Horizontal mounting Wall mounting M1 M2 M2 M1 M2 M3 y X x Y y z X x Y X x Z m1 x g m2 x g m3 x g Vertical mounting Mounting orientation Horizontal Ceiling Wall Vertical m1 m2 m3 m4 Static load m M3 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment M1 m1 x g x Y m2 x g x Y m3 x g x Z y z M2 z Y