I J 5.5 11 5.7 11.2 2 x M5 x 0.8 thread depth 8 5H9 depth 5 +0.030 0 N x M5 x 0.8 thread depth 6 5H9 depth 5 +0.030 0 5.7 11 6 1 1 28 24.5 58 29 24 49 14.5 24.5 3.5 F 6.5 4 x M5 x 0.8 thread depth 7 14 -1 x F 2 N 21 3 x M6 x 1 thread depth 10 M 10 KA 21 10 5.5 Bottom view of MXQR16-50 NA x M5 x 0.8 thread depth 6.5 45 35 13 K 21 33.7 0.3 10 5.5 5.5 37 Z ZZ G (NN-1) x H H 22.4 7.6 22.4 7.6
Type 40 Applicable solenoid valve SYJ514-SYJ514M-SYJ524-SYJ524M-How to Order SS3YJ5--40-05 -M5 R port 1/8 P port 1/8 P, R port thread type Stations A port size 02 : 20 2 stations : 20 stations Applicable blanking plate assembly SYJ500-10-3A Nil A A Rc G NPT NPTF M5 01 M5 x 0.8 1/8 F N T A port M5 x 0.8, 1/8 Note) For more than 9 stations, supply air to both sides of P port and exhaust air
DIN rail clamping screw 2n x C3, C4, M5 C3: 3.2 One-touch fitting assembly C4: 4 One-touch fitting assembly M5: M5 thread 2n x C3, C4, M5 C3: 3.2 One-touch fitting assembly C4: 4 One-touch fitting assembly M5: M5 thread 45.5 2.5 10.5 (5) Dimensions Formula L1 = 11n + 20 n: Station (Maximum 20 stations) 21.5 n L 1 2 3 4 5 6 7 8 9 10 L1 31 42 53 64 75 86 97 108 119 130 L2 50 62.5 75 87.5 100
of lead wire 10 Flat washer 4 pcs. 2 x 4 x M4 x 0.7 Effective depth 7 GH9 H D C (mm) A B C D E F G H Model A 35.5 + Clamp stroke 0 0.043 8 MKB12 MKB16 5 5.5 11h9 6 25 32 M3 x 0.5 15.5 48 + 2 x Clamp stroke 2 x 4 x 6.5 Counterbore depth 4 0 0.043 7 6.5 14h9 29 38 M5 x 0.8 20 (mm) M + Clamp stroke Model M N S O P Q R With arm: MK -N 12 16 11 MKB12-N MKB16-N N 8 8 29 20 4 M3 x 0.5 18.5 11 36
+ 96 n: Stations (Maximum 12 stations) * Including 1 station for mounting terminal box.
L M N NN P Q QQ R X Y U Model 2-3.4 through 2-6.5 counterbore with depth 3.3 4-M3 x 0.5 with depth 4.5 2-M4 x 0.7 with depth 7 2-M3 x 0.5 with depth 5 M3 x 0.5 x 10 46 17 44 15 7.5 2-M4 x 0.7 35 20 4 8 20 6 33.6 8.5 7 30 M5 x 0.8 x 5 CXS10 2-4.3 through 2-8 counterbore with depth 4.4 4-M4 x 0.7 with depth 5 M5 x 0.8 x 10 2-M4 x 0.7 with depth 6 2-M5 x 0.8 with depth 8 38.5 58 20 56 18 9
1 2 3 4 5 6 7 Stations D-side 8 U-side M12 Female thread 2-C8 3(R) port 0 DIN rail clamp screw 1 62.5 60 (12) 40.5 25 9.5 7.5 18.5 M12 Male thread 20.5 (7.5) 2n-C3, C4, C6, M5 C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread 2-C8 1(P) port 34 P = 10.5 (mm) Formulas: L1 = 10.5n + 45, L2 = 10.5n + 93.5 n: Stations (maximum 16 stations) n L L1 L2 L3 L4
No indication is necessary for Rc; however, indicate N for NPT, and F for G. Separate interfaces are required for modular unit. T-interface (T) M5 x 0.8, 1/8, 1/4, 3/8, 1/2 Factory mounting of a piping adapter on the AC models is available as a special order. Using a T-interface facilitates the redirection of air flow.
Base mounted) Applicable solenoid valve SYJ540SYJ543SYJ550SYJ553Applicable blanking plate assembly SYJ5000-21-1A How to Order SS5YJ5 40 05 M5 P port 1/8 P, R port thread type Stations 02 2 stations Nil F N T Rc G NPT NPTF : : 20 20 stations R port 1/8 Applicable individual EXH spacer assembly A, B port M5 x 0.8 M5 M5 x 0.8 A, B port size Applicable individual SUP spacer assembly ARBYJ5000
Nil Both sides piping type n n pcs.
(mm) <M5> <M5> Note) Weight (g) Model D1 P A M D2 L 2-applicable tubing M5 x 0.8 KJU23-M5 KJU23-01S KJU04-M5 KJU04-01S KJU06-M5 KJU06-01S 5.9 8.3 6.4 8.8 7.4 9.9 Reference dimensions after R thread installation.
M5 M5 x 0.8 (PE: Pilot EXH port) (11) Approx. 300 44.9 (Lead wire length) 14 PE (66) 46.5 13.4 16.3 41.2 8 1/8 [1(P), 3(R) port] 15 45.2 Formula: L5 = 10.5n + 9.5 L3 = 10.5n + 22.5 n: Stations (Max. 20 stations) Dimensions L n 2 3 85.5 75 54 16 41 4 98 87.5 64.5 17 51.5 5 110.5 100 75 18 62 6 123 112.5 85.5 19 72.5 7 135.5 125 96 20 83 8 148 137.5 106.5 21 93.5 9 148 137.5 117 15.5 104 10
io n ge io at of at ot ot R an R e n r ng tio ra ta n Ro io at ot R Unit Used as Flange Mount The L dimensions of this unit are shown in the table below.
Station (Maximum 24) 2-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread U side D side Stations 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 42 62.5 73 n L 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread L1 L2 L3 31 50 60.5 53 75 85.5 64 87.5 98 75 100 110.5 86 112.5
(EA)5 1 (P) 3(EB) A 4 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors 3 position exhaust center Common specifications B 2 2(B) (A)4 4 Nil N Positive common Pilot type Negative common M5: M5 x 0.5 Nil R (EA)5 1 (P) 3(EB) Internal pilot When the SI unit specifications are PNP output ( COM), the common specifications of valves
(43) 2.5 (22.5) 0.5 2n-C3, C4, C6, M5 C3: One-touch fitting ass'y for 3 2n-C3, C4, C6, M5 VQZ C3: One-touch fitting ass'y for 3 C4: One-touch fitting ass'y for 4 C4: One-touch fitting ass'y for 4 C6: One-touch fitting ass'y for 6 M5: M5 thread C6: One-touch fitting ass'y for 6 M5: M5 thread VQD 45.5 2.5 10.5 (5) 21.5 VZS Dimensions Equation L1=11n+20 n: Staion ( Max. 24 stations) 7.5 L n
VP300-224-1 (M3 x 36) VP500-224-1 (M4 x 46) VP700-224-1 (M5 x 66) Thread type Series For valve mounting 3 5 7 VPA344 VPA544 VPA744 Nil F N T Rc G NPT NPTF Caution Tightening Torque of Mounting Screw Port size Symbol 1 2 VPA344 1/8 1/4 VPA544 1/4 3/8 VPA744 3/8 1/2 M3: 0.8 Nm M4: 1.4 Nm M5: 2.9 Nm 31 Series VPA300/500/700 Air Operated Valve Base Mounted/Single Unit Series VPA300/Base Mounted
Motor Servo Motor (24 VDC) Controller Controller E ProgramlessType E AC Servo Motor Controller E Step Data InputType New New New New New New Series LECSA/LECSB Series LECP6/LECA6 Series LECP1 N Pulse input type N Absolute encoder (LECSB) N Built-in positioning function (LECSA) N 64 positioning points N Teaching box, controller setting kit input N 14 positioning points N Control panel setting