Body Size: 20, Model Type: Filter Regulator + Lubricator, Thread: NPT, Port Size: 1/4, Float Type Auto Drain: C [N.C. (Normally Closed)], Pressure Gauge/Digital Pressure Switch: Square Embedded Type Pressure Gauge, w/Limit Indicator, Attachment: Mounting Position: AF + AFM + AR + V, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator),

Body Size: 20, Model Type: A (Filter Regulator + Lubricator), Thread: N (NPT), Port Size: 02 (1/4), Float Type Auto Drain: C [N.C. (Normally Closed)], Pressure Gauge/Digital Pressure Switch: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate

Body Size: 20, Model Type: Air Filter + Regulator + Lubricator, Thread: N (NPT), Port Size: 02 (1/4), Float Type Auto Drain: C [N.C. (Normally Closed)], Pressure Gauge/Digital Pressure Switch: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate

.· Y210-□01-A, 02-A applicable models: AC20-A, AC20B-A, AC20C-A.· Y310-□01-A, 02-A applicable models: AC25-A, AC25B-A, AC25C-A · Y310-□01-A, 02-A applicable models: AC30-A, AC30B-A, AC30C-A.· Y410-□02-A, 03-A applicable models: AC40-A, AC40B-A, AC40C-A.· Y510-□02-A, 03-A applicable models: AC40-06-A, AC40B-06-A.· Y510-□02-A, 03-A applicable models: AC40C-06-A.

Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: F (G), Port Size: 02 (1/4)

Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: F (G), Port Size: 01 (1/8)

Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: N (NPT), Port Size: 02 (1/4)

Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: N (NPT), Port Size: 01 (1/8)

Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: Rc, Port Size: 01 (1/8)

Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: Rc, Port Size: 02 (1/4)

Rc1/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC20-B, AC20B-B

Rc1/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC20-B, AC20B-B

Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC20-B, AC20B-B

: G1/4, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC20-B, AC20B-B

Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC20-B, AC20B-B

Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC20-B, AC20B-B

How to Order AD402 04 A D Semi-standard symbol: When plural options are required, indicate them in alphanumeric order.

M12 4-pin Socket, D-code 4 Configuration Pin No. Signal name The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

(power supply voltage monitor (Output) is valid) 1 0 V (Output) Hudcova 78a, CZ-61200 Brno, Czech Republic Green LED flashes. (1Hz) Green LED flashes. Received power level is 2.