screw D-B5/B64 D-B59W D-G5NTL D-G5NBL BA-01 BA-02 BA-32 BA-04 Cylinder tube BD1-01M BD1-02M BD1-02 BD1-04M D-A3/A44 D-G39/K39 qBMA2-: A set of a and b in the figures. wBJ3-1: A set of c, d and e in the figures.

Specifications Max. operating pressure Min. operating pressure 0.8MPa 0.1MPa 5 to 50C 2.7mm2 (0.15) 180CPM VVQ1000-FPG-02 1set VQ1000-FPG-C6M5-D 2 pcs.

Stations S42R Type Coil is located on same side as the A port. 2 stations 02 Coil is located on same side as the A port. S ... ...

Series VS R8 S HOW TO ORDER ISO5599/2 VALVE MANIFOLD VV8 2 5 03 TU1 03 D T W1 W1=NEMA 4 ISO Size Port Thread Code 1 Size 1 2 Size 2 3 Size 3 NIL Rc (PT) T NPTF F G(PF) Location of port 1(P), 5(EA), 3(EB) Number of Stations D D side 2 2 stations U U side B Both side 9 9 stations Size of port 1(P), 5(EA), 3(EB) Symbol Size Applicable ISO size 02 1/4 Size 1 U side option 03 3/8 Size 1

Bore size (mm) Auto switch model 40 50 63 80 100 D-A9/A9V D-M9/M9V D-M9W/M9WV D-M9A/M9AV BA7-040 BA7-040 BA7-063 BA7-080 BA7-080 D-A5/A6 D-A59W D-F5/J59 D-F5W/J59W D-F59F/F5NT BT-04 BT-04 BT-06 BT-08 BT-08 D-A3C/A44C D-G39C/K39C D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 Mounting example of D-A9(V)/M9(V)/M9W(V)/M9A(V) BA4-040

/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B

FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R VQ7-6-FPG-DValve replacement parts FHG FJG FIG FHG FJG FIG Description Material VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-D-R VQ7-6-DNo.

Memory map of output data Data (2 byte) Output area Branch connector (OUTPUT) MSB LSB MSB LSB 15 8 7 0 byte (d) byte (d+1) Word(c) COM A byte (d+2) byte (d+3) Word(c+1) COM B byte (d+4) byte (d+5) Word(c+2) COM C byte (d+6) byte (d+7) Word(c+3) COM D : : (c, d=0 to) NOTE Read carefully the user manual of PLC which is used as a master.

Table(2) Rated Voltage-Electrical Entry-Electrical Option PAX Table(1) Connection Size and Applicable Model Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G C D, T G, C T PB S L, Z S L, Z S Note ) Connection Applicable model VXP2130-02 VXP2130-03,VXP2140-03 VXP2130-04,VXP2140-04 VXP2150-06

-020 BMA2-025 BMA2-032 BMA2-040 9 8 10 10 9 8 10 10 14 13 13 14 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F D-G5NTL D-G5NBL 9 8 10 10 4.5 4 4 5 BA-01 BA-02 BA-32 BA-04 D-H7C 9 7 8.5 10 D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4.5 4 4 5 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C D-G59F D-G5NBL BM1-01 BM1-02 BM1-32 BM1-04 5.5 5 5 6 40 40 35 45 Since this is a guideline including hysteresis, not

In-line D-M9N D-M9P D-M9B D-M9NA D-M9PA D-M9BA Electrical entry Special function Indicator light Wiring (Output) Applicable load Smbol A B C E F G 3-wire (NPN) 3-wire (PNP) 2-wire Relay, PLC IC circuit 24 V 5 V, 12 V Grommet Yes 12 V Yes 3-wire (NPN) 3-wire (PNP) 2-wire 24 V 5 V, 12 V Relay, PLC IC circuit Water resistance (2-color display) Grommet 12 V Option (For detail, refer to page

H 364 H 364 J 116 H 364 V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Table B FLOW CONFIGURATION VALVE NO.

H 364 H 364 J 116 H 364 V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Table B FLOW CONFIGURATION VALVE NO.

Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models. 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Connector 12 V Yes 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire

Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models. 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Connector 12 V Yes 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire

V 10 10 10 T = t x = 110 x = 110 (s). V 10 10 10 T = t x = 2.4 x = 24 (s).

D-F 9~V comply With IEC529, IP65, and JISC0920 Jet stream proof structure.

D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.