59 56 69.5 104 112 63 57.5 62 57.5 104 121 112 121 56 59.5 56 62.5 56 D-A9 and D-A9V cannot be mounted on 50.
31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS090 Series 5-14 HRX-OM-T004 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-R028 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
W1 W1=NEMA 4 ISO Size Port Thread Code 1 Size 1 2 Size 2 3 Size 3 NIL Rc (PT) T NPTF F G(PF) Location of port 1(P), 5(EA), 3(EB) Number of Stations D D side 2 2 stations U U side B Both side 9 9 stations Size of port 1(P), 5(EA), 3(EB) Symbol Size Applicable ISO size 02 1/4 Size 1 U side option 03 3/8 Size 1, 2 SU0 No option 04 1/2 Size 1, 2 SUQW DeviceNet serial interface (Note) 06
How to Order Integrated Display Type PF2A7 H M Flow rate range Unit specification High flow rate type 03 06 12 150 to 3000 l/min 300 to 6000 l/min 600 to 12000 l/min Lead wire (Refer to page 35.)
31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS Series 5-14 HRX-OM-M091 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-Q033 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS100/150 Series 5-14 HRX-OM-S010 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
Hs G 1/2 (applicable cable O.D. 6.8 to 9.6) D-G39/K39 D-A3 56 34 B 36 A 49 Auto switch G 1/2 (applicable cable O.D. 6.8 to 9.6) Approx. Hs D-A44 56 B 36 Auto switch 49 A Approx.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
165 56 Reset button RESET PROCESS PUMP FLUID OUT 167 AIR SUP 132.5 FLUID I N 125.5 103.5 AIR EXH 58.5 48.5 202 114 3.5 3 AIR EXH (pilot air exhaust port) FLUID IN Rc 1/2, 3/4 Rc 1/4 5 Process Pump Air Operated Type (External Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 3 PA3000 Body size Connection port size 03 04 06 3 5 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 3/8 standard
165 56 Reset button RESET FLUID OUT PROCESS PUMP 167 AIR SUP 132.5 FLUID I N 125.5 103.5 AIR EXH 58.5 48.5 202 114 3.5 3 AIR EXH (Pilot air exhaust port) FLUID IN Rc 1/2, 3/4 Rc 1/4 17-5-152 13 Process Pump Air Operated Type (External Switching Type) Series PA3000/5000 How to Order VC 1 1 PA 3 03 3 PA3000 VDW VQ Port size Body size VX2 3 5 03 04 06 3/8 standard 1/2 standard 3/8(10A): PA3
How to Order Coil Assembly (DC for XSA) VX021 001 C B 05 Rated voltage Note1) Coil assembly 05 24VDC 06 12VDC Applications 6VDC 51 Size part no. Applicable Series 001 002 No.1 Solenoid No.2 Solenoid XSA1 XSA2 003 No.3 Solenoid XSA3 53 48VDC 100VDC 55 Note 1) If the leading "0" is removed from voltage symbols 05, 06, these are the same as the solenoid valve symbols.
165 56 Reset button RESET PROCESS PUMP FLUID OUT 167 AIR SUP 132.5 FLUID I N 125.5 103.5 AIR EXH 58.5 48.5 202 114 3.5 3 AIR EXH (pilot air exhaust port) FLUID IN 1/2, 3/4 1/4 5 Series PA3000/5000 Process Pump Air Operated Type (External Switching Type) How to Order 1 1 PA 3 03 3 PA3000 Body size Connection port size 03 04 06 3 5 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 3/8 standard
165 56 Reset button RESET PROCESS PUMP FLUID OUT 167 AIR SUP 132.5 FLUID I N 125.5 103.5 AIR EXH 58.5 48.5 202 114 3.5 3 AIR EXH (pilot air exhaust port) FLUID IN Rc 1/2, 3/4 Rc 1/4 5 Process Pump Air Operated Type (External Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 3 PA3000 Body size Connection port size 03 04 06 3 5 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 3/8 standard
C10: 10 (SMC) C12: 12 (SMC) 56 One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12 (SMC) ZK2 Combination Manifold * These figures show the JJ5SY5-10S3V-05D-C12. * Refer to page 99 for dimensions of external pilot (Made to Order) and silencer.
, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
*-A AR30-A AFM30-A AL30-A AR30-A AFM30-A AL30-A AR30-A AF40-A AF40-A AW40-A AF40-A AW40-A AC40*-A AR40-A AFM40-A AL40-A AR40-A AFM40-A AL40-A AR40-A AF40-06-A AF40-06-A AW40-06-A AF40-06-A AW40-06-A AC40*-06-A AR40-06-A AFM40-06-A AL40-06-A AR40-06-A AFM40-06-A AL40-06-A AR40-06-A 10 Option / Semi-standard : Select one each for a to m.
61 56 58.5 56 56.5 55.5 57.5 55.5 66 56 66 58.5 68 102.5 112.5 61.5 57.5 Auto switch model D-F5l D-J59 D-F5lW D-J59W D-F5BA D-F59F D-F5NT D-A3lC D-G39C D-K39C D-A44C Bore size Hs Ht Hs Hw Hs Hw 40 38 31.5 73 69 81 69 50 42 35.5 78.5 77 86.5 77 63 47 43 85.5 91 93.5 91 80 53.5 51 94 107 102 107 100 61 57.5 104 121 112 121 19 Series CLA2 Minimum Stroke for Auto Switch Mounting n: Number of
BA -08 BA -10 BA -32 BA -02 BA -01 CX D-G5NBL 35 40 45 45 45 40 50 45 D-G5/K5 D-B7/B8 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 BM1 -06 Since this is a guideline including hysteresis, not meant to be guaranteed.