(mm) Model H 1(P) 2(A) L3 L4 L5 L6 Q L1 L2 M1 C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-M5-04F VHK-M5-06F 2.0 1.2 19 49 11 21 50 13 M5 4 6 VHK-B1A 44.5 14.5 1 27 22 16.5 26 29.1 53.9 24.3 29.6 52.9 23.8 15.8 16.8 3.5 11 18 41 16.5 VHK-01S-04F VHK-01S-06F VHK-01S-08F 62.2 26.2 36 18.7 31 58 17 18 41 55.4 23.8 31.6 56.9 24.3 32.6 16.5 3.5 15.8 16.8 11 7.2 9.7 3.4 1.2 21 51 11 23 53 13 4 6
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm , Max. operating pressure: 1.0MPa, Fluid: air, VALVE, SOL, VALVE, VHK2 FINGER VALVE, DA, VHK2/3 BODY PT 1/8, .22046 lb
, Ambient and fluid temperature: 0 to 60C, FINGER VALVE, VALVE, VHK2 FINGER VALVE, UA, VHK2 BUILT IN FITTING .05511 lb, .05511 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm , Max. operating pressure: 1.0MPa, Fluid: air, VALVE, FINGER, VALVE, VHK2 FINGER VALVE, UA, VHK2 BUILT IN FITTING .07480 lb, .07480 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, FINGER VALVE, VALVE, VHK2 FINGER VALVE, WA, VHK2 BUILT IN FITTING >1/4, 0.44092 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm , Max. operating pressure: 1.0MPa, Fluid: air, FINGER VALVE, VALVE, VHK2 FINGER VALVE, UA, VHK2 BUILT IN FITTING <1/4, .11344 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm , Max. operating pressure: 1.0MPa, Fluid: air, FINGER VALVE, VALVE, VHK2 FINGER VALVE, WA, VHK2 BUILT IN FITTING >1/4, .41746 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm , Max. operating pressure: 1.0MPa, Fluid: air, FINGER VALVE, VALVE, VHK2 FINGER VALVE, UA, VHK2 BUILT IN FITTING <1/4, .20084 lb
Size: 2 (2 Port Valve), Handle Prevention: A (w/Handle Prevention Function), P Side Port Size: M5, A Side Port Size: 04F (Ø4), Knob Color: R (Red)
Size: 3 (3 Port Valve), Handle Prevention: A (w/Handle Prevention Function), P Side Port Size: 06F (Ø6), A Side Port Size: 04F (Ø4), Knob Color: R (Red)
Size: 2 (2 Port Valve), Handle Prevention: A (w/Handle Prevention Function), P Side Port Size: 01S (PT 1/8), A Side Port Size: 01S (PT 1/8), Knob Color: R (Red), Bracket: L (L Bracket)
Finger valve series VHK has a large effective area of 2.0 to 17.5mm². This series begins with a minimum tube O.D of ø4. The valve direction clearly indicates whether the valve is open or closed (shut to open is counter- clockwise). Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's
Finger valve series VHK has a large effective area of 2.0 to 17.5mm². This series begins with a minimum tube O.D of ø4. The valve direction clearly indicates whether the valve is open or closed (shut to open is counter- clockwise). Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's
Finger valve series VHK has a large effective area of 2.0 to 17.5mm². This series begins with a minimum tube O.D of ø4. The valve direction clearly indicates whether the valve is open or closed (shut to open is counter- clockwise). Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's
Finger valve series VHK has a large effective area of 2.0 to 17.5mm². This series begins with a minimum tube O.D of ø4. The valve direction clearly indicates whether the valve is open or closed (shut to open is counter- clockwise). Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's
AS2200-01S-X785 PILOT CHECK VALVE
Only VHK2 series 2-port valves can be used for vacuum (up to -100 kPa).
Note 1) The vacuum source for the VHK2 is piped to the 2 (A) side.
Note 2) Valve leakage is allowed for the VHK series.
(mm) Model KQGL04-00 KQGL06-00 KQGL08-00 KQGL10-00 KQGL12-00 4 6 8 10 12 KQGH04-M5 KQGH04-01S KQGH06-M5 KQGH06-01S KQGH06-02S KQGH08-01S KQGH08-02S KQGH08-03S KQGH10-02S KQGH10-03S KQGH12-03S KQGH12-04S M5 4 R1/8 M5 6 R1/8 R1/4 Male Branch Tee Male Branch Tee R1/8 8 R1/4 Applicable tubing O.D.
Size: 2 (2 Port Valve), Handle Prevention: A (w/Handle Prevention Function), P Side Port Size: 06F (Ø6), A Side Port Size: 04F (Ø4), Knob Color: R (Red), Bracket: L (L Bracket)
Size: 3 (3 Port Valve), Handle Prevention: A (w/Handle Prevention Function), P Side Port Size: 06F (Ø6), A Side Port Size: 04F (Ø4), Knob Color: R (Red), Bracket: L (L Bracket)