Motor: 2-Phase Stepping Motor, Ball Screw Lead: 12mm, Stroke: 50mm, Home Position Switch: Yes (Cable Length 0.3m), Brake: None, Auto Switch: M9NL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: 2 pcs., Proximity Switch: -, Number of Proximity Switches: -
Motor: 5-Phase Stepping Motor, Ball Screw Lead: 6mm, Stroke: 100mm, Home Position Switch: Yes (Cable Length 0.3m), Brake: w/Motor Brake, Auto Switch: M9NL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: 2 pcs., Proximity Switch: GXL-8FI--3 Wire NPN, N.O., A Contact, 1M, Number of Proximity Switches: 2 pcs.
Motor: 2-Phase Stepping Motor, Ball Screw Lead: 6mm, Stroke: 50mm, Home Position Switch: Yes (Cable Length 0.3m), Brake: None, Auto Switch: M9NL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Number: 1 pc., Proximity Switch: -, Number of Proximity Switches: -
Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 16, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9NL
Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: [Other] CF, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9NL
Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9NL
Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.12~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9NL
Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9NL
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: M9NL--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 3M
Item CH1 CH2 Setting range 15 to 25 20 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.
Item CH1 CH2 Setting range 5 to 35 10 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.
Item CH1 CH2 Setting range 5 to 35 10 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.
Air Filter + Mist Separator + Regulator ACG20C/30C/40C Options/Attachments Part No. Options/Attachments part no. ACG20C ACG30C ACG40C Model Description Pressure gauge Note 1) 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.