Calculation of Guide Load Factor 1 Operating Conditions Mounting Orientation Cylinder MY1MW40-500 Average operating speed a 200 mm/s Mounting orientation Horizontal mounting z 1. Horizontal mounting 2. Wall mounting y Wd: Workpiece (500 g) P.1230 x y Wc: MHL2-16D1(795 g) x z Wa: Connection plate t = 10 (880 g) x MY1MW40-500 3. Ceiling mounting 4.

SS5Y31, #2 + #11 M type plug connector .

11 6.4 115 84 44.5 303 264 43 110 282 98 96 70 50 3.3 318 20 11 11 6.4 117.5 84 44.5 279 45 110 292 98 101 70 50 3.3 318 20 11 117.5 44.5 11 6.4 84 280 46 110 297 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.

Maximum Up to 300 mm/s Up to 400 mm/s Up to 500 mm/s Coefficient 1.7 1 0.6 .

Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to

13 13 8 10 10 53 8 9 40 25 to 500 21 40 24 24 41 18 16 21 12 17 17 11 16 16 54 10 11 48 25 to 500 21 (mm) Bore size (mm) K NN P S T V W ZZ MM NB IA NA -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 5 M22 x 1.5 1/8 81 9.5 4.5 6.5 138 M8 x 1.25 15 23f8 17 25 5.5 M24 x 1.5 1/8 81 11 3.5 5.5 143 M10 x 1.25 15 25f8 17 32 7.5 M30 x 1.5 1/8 87 13 3 4 159 M14 x 1.5 15 31f8 18 40 7.5

500 500 500 Mey m 0 0 0 0 0 2 1 3 4 5 0 15 10 5 0 15 10 5 20 25 30 0 15 10 5 20 Vertical L7 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 1500 1500 1500 1500 1000 1000 1000 1000 L8 [mm] L8 [mm] L8 [mm] L8 [mm] Z 500 500 500 500 Mep m 0 0 0 0 0 2 1 3 4 5 0 15 10 5 0 15 10 5 20 0 15 10 5 20 25 30 L8 Work load [kg] Work load [kg] Work load [kg] Work load [kg] Calculation of Guide

Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It

115 44.5 11 6.4 84 3.3 303 264 43 105 282 98 96 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 279 45 105 292 98 101 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 280 46 105 297 Note 1) For AC20 only, the position of the pressure gauge is above the piping center.

block C 45 B A 220 4 x 11 (mm) A B 240 C 14 Transformer part no.

*1: To use the power of the device, the total load current must be 500 mA or less.

500/60 600/65 750/80 100/11 200/22 300/35 1000/110 Symbol Drain discharge method 60L, 60S 75L, 75S 100L, 100S 60, 60H 75, 75H 100, 100H 40 75/25 110/40 170/57 240/80 300/100 10, 10H 20, 20H 3, 3H 5, 5H 30, 30H, 30L 50, 50H, 50L 60 S 50/27 150/85 100/54 Nil Manual valve Component equipment C Note 2) N.C. auto drain Note 1) Note 2) Micro mist separator with pre-filter Regulator Contents

11 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 60 70 86 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 8 11 11 13 16 14 18 18 22 26 19.4 16.4 18.4 21.4 21.4 27 30 31 37 40 147 157 173 189 203 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 Up to 500 Up to 600 Up to 600 Up to 750 Up to 750 MK(2) RS Q G The minimum stroke of the one with rod

(Example) CS2L160-500 28 to 30 160 I 3/4 BaSIC weight . 12.45 (kg) Additional weight .. .. 2 23 (kg!1 00 mm) Cylmder stroke .. 500 (mm) 3.

Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.

11 20.5 41 (P, EA, EB port) 1/8 L plug connector (L): 10-SY3240(R)-L-01 M8 connector (WO): 10-SY3240(R)-WO-01 M plug connector (M): 10-SY3240(R)-M-01 108.6 [113] Approx. 300 (Lead wire length) 38.1 53.5 [60.5] 58 M8 x 1 40.5 (Lead wire length) Approx. 300 64.6 [71.6] 79 89 [93.4] 20.5 11 11 20.5 11 92 106.8 20.5 11 11 11 7.5 16.5 7.5 16.5 24.5 7.5 16.5 24.5 24.5 50 Note) Refer to page 176

A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) Model 15 20 25 30 LJ1H20PC-500LJ1H20PC-600LJ1H20PC-700LJ1H20PC-800LJ1H20PC-900LJ1H20PC-10001000 1000 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 930 740 600 500 9 Standard Motor Horizontal Mount Motor Output High Rigidity Direct Acting Rolled Ball Screw 100 W 15 mm/10 mm lead Guide Series

IP65 2 outputs ZSE/ISE20C p. 19 Air General fluids Pressure range Pressure range 100 kPa 0 100 kPa 500 kPa 1 MPa 100 kPa 0 100 kPa 500 kPa 1 MPa 2 MPa 5 MPa 101 kPa 101 kPa Withstand pressure 500 kPa Withstand pressure 500 kPa 0 0 100 kPa 100 kPa 100 kPa 100 kPa Withstand pressure 500 kPa Withstand pressure 500 kPa 100 kPa 100 kPa Withstand pressure 2 MPa 1 MPa 1 MPa Withstand pressure 1.5

PSE531-M5 Pressure Sensor: Series PSE530 Model 0 to 101 kPa Rated pressure range 500 kPa Proof pressure Air, Non corrosive gas Applicable fluid 12 to 24 VDC (Ripple 10% or less) Power supply voltage 15 mA or less Current consumption Analog output (1 to 5 V, Output impedance: Approx. 1 k) Output specifications For details, refer to Best Pneumatics Vol. 16. 13-14-11 11 Vacuum System Peripherals

22 17 6 1/8 8.5 10 46 97 45.5 12 32.5 83 13 13 30 27 16 13 63 40 to 500 30 22 8 1/8 10 14 52 104 52.5 12 38 91 14 16.5 35 32 20 14 75 50 to 600 35 27 11 1/4 12.5 18 65 120.5 58.5 15 46.5 104.5 15.5 19 40 32 20 14 90 63 to 600 35 27 11 1/4 17.5 18 75 134.5 68 12 56.5 119.5 16.5 23 45 37 25 20 102 80 to 750 40 32 13 1/4 22 22 95 169 81 18 72 150 19 33 45 37 30 20 116 100 to 750 40 41 16 1/