E 11 D E 11 3 3 3 3 3 3 M10 x 1 M10 x 1 M10 x 1 Q Q Q D D (F) (F) (F) P P P Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) S S S 31 8 31 8 31 14.9 14.9 14.9 R R R 6 6 6 M5 x 0.8 M5 x 0.8 M5 x 0.8 8 Y Y Y A A A C a a a C C b B 20 30 21 31 Dimensions Model Dimensions Model Dimensions a 3.5 4 5 6 A 4.5 5 6 7 b 7 B 8 C Y a 4 5 6 8 A 5 6 7 9 C 2 x
E 11 D E 11 3 3 3 3 3 3 M10 x 1 M10 x 1 M10 x 1 Q Q Q D D (F) (F) (F) P P P Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) S S S 31 8 31 8 31 14.9 14.9 14.9 R R R 6 6 6 M5 x 0.8 M5 x 0.8 M5 x 0.8 8 Y Y Y A A A C a a a C C b B 20 30 21 31 Dimensions Model Dimensions Model Dimensions a 3.5 4 5 6 A 4.5 5 6 7 b 7 B 8 C Y a 4 5 6 8 A 5 6 7 9 C 2 x
E 11 D E 11 3 3 3 3 3 3 M10 x 1 M10 x 1 M10 x 1 Q Q Q D D (F) (F) (F) P P P Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) S S S 31 8 31 8 31 14.9 14.9 14.9 R R R 6 6 6 M5 x 0.8 M5 x 0.8 M5 x 0.8 8 Y Y Y A A A C a a a C C b B 20 30 21 31 Dimensions Model Dimensions Model Dimensions a 3.5 4 5 6 A 4.5 5 6 7 b 7 B 8 C Y a 4 5 6 8 A 5 6 7 9 C 2 x
11 13 13 14 Average speed Va (mm/s) Collision speed V (mm/s) 13 13 13 13 18 42 41 42 41 23 31 31 31 31 41 36 19 19 19 19 27 84 75 84 75 84 75 36 47 47 47 47 66 57 Note) Use the average speed when calculating static moment.
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit T kit (Terminal block box) S kit 0 1 2 With cable (0.6
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit T kit (Terminal block box) S kit 0 1 2 With cable (0.6
IN side OUT side Straight R Straight V Straight R Straight V Fitting size Elbow S Elbow T Elbow U Elbow W Elbow X Elbow Y Fitting size Elbow S Elbow T Elbow U Elbow W Elbow X Elbow Y 4, 5/32 4, 5/32 2.5 6 11 35.5 2.5 6 11 35.5 2.5 6 11 37.5 2.5 6 11 37.5 6 6 3 6.5 11 36 3 6.5 11 36 3 6.5 11 38 3 6.5 11 38 1/4 1/4 6.5 6 11.5 38.5 6.5 6 11.5 38.5 6.5 6 11.5 40.5 6.5 6 11.5 40.5 488 Regulator
5 6 7 8 9 1 0 1 11 2 1 31 41 5 7 8 9 10 11 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R20 CY3R40 500 200 300 100 200 50 100 20 30 40 50 30 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 7 8 9 10111213 0 1 2 3 4 5 6 7 8 9 1 0 1 11 2 1 31 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R25
Model Cushion Auto switch mounting Bore size (mm) 20 25 32 40 20 25 32 40 Action Standard stroke (mm) Port size Lubrication Model Rubber Air 10-CM2X20 10-CM2X25 10-CM2X32 10-CM2X40 11-CM2X20 11-CM2X25 11-CM2X32 11-CM2X40 Relief type Vacuum suction type 1/8 1/4 25, 50, 75, 100, 125 150, 200, 250, 300 Non-lube Double acting single rod 1/8 1/4 174 Low speed cylinder 10CM2X/11-CM2X Specifications
With light/surge voltage suppressor Z Pilot type Rated voltage Electrical entry 5 24 VDC 6 12 VDC Nil Internal pilot R External pilot Grommet L plug connector M plug connector G: Lead wire length 300 mm MN: Without lead wire M: With lead wire (Length 300 mm) L: With lead wire (Length 300 mm) V 6 VDC S 5 VDC R 3 VDC Common specifications LN: Without lead wire LO: Without connector MO: Without
or 3/8" 67.0 67.0 60 121 7380 1 10 mm or 3/8" 75 189 11500 1 10 mm or 3/8" 502 195 11900 1 10 mm or 3/8" 130.0 130.0 602 282 17200 1 10 mm or 3/8" 752 441 26900 1 10 mm or 3/8" B1J B1JA Stroke volume dm3 / in3 NPT Piping Air (s) Spring (s) Piping Air (s) Spring (s) Piping Air (s) Spring (s) 6 0.47 28.7 3/8 10 mm or 3/8" [6 mm or 1/4" (x)] 10 mm or 3/8" [6 mm or 1/4" (x)] 8 0.9 55
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
P 13 5 10 10 14 14 5-M5 0.8 (Piping port) 15 [ ] for AC L type plug connector (L) : SYJ3140L -M5 M type plug connector (M) : SYJ3140M -M5 33.5 33.5 23.2 (Mounting holes) 22 4 23.2 (Mounting holes) 22 4 B A B A 11 2.5 17.5 11 2.5 17.5 A B A B (Lead wire length) 50.7 64.3 About 300 52.6 [59.1] About 300 54.7 [56] (Lead wire length) 41.5 [48] 41.5 [48] 33.5 33.5 29.1 22.5 22.5 R2 R1 P R2 R1
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
400 500 1000 1500 0.05 0.5 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Technical Data Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) 1349 Mechanically Jointed Rodless Cylinder with Protective Cover Slide Bearing Guide Type, Cam Follower Guide Type MY1W Series 16, 20, 25, 32, 40, 50, 63 How to Order MY1 M W K 300
10 8 6 11 9 9 8 94 83 77 75 16 13 12 11 5.5, 9.5 counterbore depth 6 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 37 1/8 55 135 33 1/8 45 117 29 1/8 44 111 27 1/8 38 104 26 21 18 15 32 24 22 18 6.6, 11 counterbore depth 7 9, 14 counterbore depth 9 11, 17.5 counterbore depth 12 38 32 46 41 50 1/4 64 161 63 Up to 300 35 32 32 27 20 11 45 2 7 72 76.6 50 Up to 300 35 32 30 12 12 27 20 45 11 2 7
A port side) / SS3YJ3-S41Stations -M3 26.1 L1 + + + + + 3.5 L2 (Light/surge voltage suppressor) 11 P R P R 26.6 22 Approx. 300 (Lead wire length) 48.8 [51] L1 2-3.5 (For mounting) L2 3.5 Manual override Manual override (Pitch) P=10.5 12.5 5 M5 x 0.8 (P, R port) Approx. 300 (Lead wire length) 2-3.5 (For mounting) 48.8 [51] P R 26.6 P R 13 22 (Station n) (Station 1) 11 (Pitch) P=10.5 12.5
100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 57 70 82 95 120 145 170 64 77 89 102 127 152 177 32 12.5 25 37.5 50 75 100 125 40 12.5 25 37.5 50 75 100 125 6-10-11 12 Series C76 Dimensions with Mounting Bracket [First angle projection] Double acting, Single rod Rod foot (Flange): C76F32A, C76F40A LT W TF