Special Applications: Clean Series, Body Size: 20, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: None
Special Applications: Clean Series, Body Size: 20, Reverse Flow: Reverse Flow Mechanism, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: None
Special Application: 10-AW (Clean Series), Body Size: 20, Reverse Flow: K (Reverse Flow Mechanism), Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: 2 (Metal Bowl), Option 2: JNR (JN + Right to Left Flow Direction)
Special Application: 10-AW (Clean Series), Body Size: 30, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: None, Option 2: J (Drain Guide)
Special Application: 10-AW (Clean Series), Body Size: 30, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: None, Option 2: JN (Drain Guide + Non-relieving Type)
Special Applications: 10-AR (Clean Series), Body Size: 25, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: 1N (1+N)
Special Applications: 10-AR (Clean Series), Body Size: 25, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: N (Non-relieving)
Special Applications: 10-AR (Clean Series), Body Size: 20, Reverse Flow: K (Reverse Flow Mechanism), Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: N (Non-relieving)
Special Application: 10-AW (Clean Series), Body Size: 40, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): B (Bracket), Option 1: 6 (Nylon Bowl), Option 2: J (Drain Guide)
Special Applications: Clean Series, Body Size: 25, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: 1+N
Special Applications: Clean Series, Body Size: 25, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: Non-relieving
Special Applications: Clean Series, Body Size: 20, Reverse Flow: Reverse Flow Mechanism, Thread: Rc, Port Size: 02 [1/4 (Size 20, 25, 30, 40)], Accessory, Not Attached: B [Bracket (Size 20 to 60)], Option: Non-relieving
Special Application: Clean Series, Body Size: 20, Reverse Flow: Reverse Flow Mechanism, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): Bracket, Option 1: Metal Bowl, Option 2: JN + Right to Left Flow Direction
Special Application: Clean Series, Body Size: 30, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): Bracket, Option 1: None, Option 2: Drain Guide
Special Application: Clean Series, Body Size: 30, Reverse Flow: No, Thread: Rc, Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): Bracket, Option 1: None, Option 2: Drain Guide + Non-relieving Type
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket