Do not use solvents such as benzene, thinner etc. to clean the product including the switch cover. Use a soft cloth to remove stains. Refer to the SMC website (URL http://www.smcworld.com) for more information about troubleshooting. This operation manual refers to all standard types and is partially applicable to special models.

Make sure the trunnions do not move by hand. Slide the trunnion to the specified location. * Keep a gap between the cylinder tube and retaining bracket so that they do not contact each other (4 places).

Also, do not use the cylinder with fixed at external slider to avoid excessive moment applied to bearing of the cylinder. And, if the cylinder is mounted with axial compressing force applied, the cylinder tube is deflected and operating failure may be caused.

Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.

Do not bring objects that are sensitive to magnetism near the cylinder. The magnet is built into the cylinder. Do not bring magnetic disks, cards or tapes near the cylinder. Data may be lost. 5. If the cylinder is operated vertically with heavy loads, measures must be taken to prevent rapid extension of the piston rod when starting to operate in the downward direction.

Do not service or attempt to remove product and machinery/ equipment until safety is conrmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confrmed. 2.

Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals, etc. will result in leakage or malfunction. 4. Do not dent or scratch the mounting surface of a body and a plate. The flatness of the mounting surface may not be maintained, which would cause an increase in sliding resistance. MGPW with Rubber Bumper 63 100 50 5.

CJ1 q Do not apply more than the allowable rotating torque to the piston rod. If more than the allowable rotating torque is applied, the non-rotating guide will be deformed and there will be a significant loss of rotational accuracy. This may cause damage to the machinery.

Polyurethane TU0425 2.5mm 4mm Metric size q Do not forcibly connect piping that could apply a lateral force to the cylinder tube, as this could cause the cylinder tube to tilt and lead to a malfunction.

To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.

MX MXU Precautions on Handling Warning Mounting/Adjustment Caution MXS MXQ q Do not scratch or gouge the sliding portion of the guide rod by striking it with an object or getting an object trapped in it.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6

2 position single only Symbol Port size M5 x 0.8 SY3000 Applicable series M5 1 8 01 SY5000 1 4 SY7000 02 02 03 Type of actuation Coil specifications 1 4 Standard Nil 2 position single SY9000 3 8 T With power saving circuit (24, 12 VDC only) 1 F2: With side bracket One-touch fitting (Metric size) Symbol Port size Applicable series Power saving circuit is not available in the case of D, DO

Note 2) Do not form connection to pins indicated with . Note 3) Signal of negative-logic circuit ON (N.C.)

Do not drop nor apply excessive force. It may cause a malfunction or damage. 3. Tighten IS1000-01 applying the spanner on the PT fitting part. CD-P11 Brown Choke coil Surge absorber Blue Warning Operating Environment CD-P12 (+) Brown 1. Avoid using a switch in a magnetic environment. It may cause a malfunction. 2. Do not use in such an environment, where water or oil is splashed.

Body material in contact with fluid material Fluid Bellows Fluid entering part Non corrosive water/Air/Liquid/Inert gas Phosphor bronze Brass Stainless steel 316 Stainless steel 316 Fluids which do not corrode stainless steel 316 e.g. steam (150C or less) Ambient temperature: 80C or less.

When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. (Crimping tool: model no. DXT170-75-1) 1. Do not use with thinner, carbon tetrachloride, chloroform, acetate, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid and watermiscible cutting fluid (alkaline). 2. Operate it away from direct sunlight.