SMC Corporation of America
Elite Part Number Search
Search Results "CDM2B25-75+100Z-XC11"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.69021 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 2.42508 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.30899 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.32277 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.79896 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 2.13667 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.73613 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.17334 lb

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, front and rear

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.43824 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.20372 lb

mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA +3.00 to +21.00 mA Correspondence table for user set upper or lower limit and output value at communication error and idling (CoE object /Web server) (Data format: Offset Binary /Signed Magnitude /2s Complement) Range Set value Expected value 0..10 V CoE/Web 0 to 1050 0.00 to +10.50 V 0..5 V CoE/Web 0 to 525 0.00 to +5.25 V 1..5 V CoE/Web 75

.+20 mA 0 to 2100 +0.00 to +21.00 mA 32768 to 34868 -0.00 to -21.00 mA 0..10 V 0 to 1050 +0.00 to +10.50 V 0..5 V 0 to 525 +0.00 to +5.25 V 1..5 V 75 to 525 +0.75 to +5.25 V 0..20 mA 0 to 2100 +0.00 to +21.00 mA 4..20 mA 300 to 2100 +3.00 to +21.00 mA 1: Follow the methods below when assigning the user set upper and lower limit by GSDML file.

Lower limit Upper limit Analog input /output measurement range Settable value range Setting Value Settable value range Setting Value 0..10 V 0.00 to +10.45 V 0 to 1045 +0.05 to +10.50 V 5 to 1050 0..5 V 0.00 to +5.22 V 0 to 522 +0.03 to +5.25 V 3 to 525 1..5 V +0.75 to +5.22 V 75 to 522 +0.78 to +5.25 V 78 to 525 0..20 mA 0.00 to +20.90 mA 0 to 2090 +0.10 to +21.00 mA 10 to 2100 4..20 mA

For instructions on how to enter the security code, refer to "How to input and change the security code" on page 75. After entry, the changed security code will flash by pressing the SET button for 1 second. (At this point, the changing of the security code is not completed) Return to the change of setting again by pressing the UP or DOWN button. Press the SET button to set.

Refer to the dimension drawing (page 75) for the diameter and depth of the mounting screw holes. 15 No.PF-OMU0002-D Piping Do not connect equipment or piping which may generate a fluctuation in flow or drift at the IN side of the product. When installing a regulator at the IN side of the product, make sure that hunting is not generated.

Flow rate at normal condition 0.927 = Flow rate of standard condition -40No.PF-OMG0010-H Dimensions (in mm) PF2A703H/706H/712H Model A B C D E F G PF2A703H 55 mm 160 mm 40 mm 92 mm 67 mm 55 mm Rc1, NPT1, G1 PF2A706H 65 mm 180 mm 45 mm 104 mm 79 mm 65 mm Rc11/2, NPT11/2, G11/2 PF2A712H 75 mm 220 mm 55 mm 114 mm 89 mm 75 mm Rc2, NPT2, G2 Model H I J PF2A703H 36 mm M5 x 0.8 8 mm PF2A706H 46

Note3) Please contact SMC if you would like to change the material of the valve seal from ULTIC ARMOR to another material, or from another material to ULTIC ARMOR.. 6 XM-OMP0002-A Optional seal material FKM for PLASMA (Note 3) ULTIC ARMOR R EPDM (Note 3) Barrel Perfluoro R Kalrez R Chemraz R VMQ (Note 3) Seal material Compound No. 2101-80. 70W 4079 SS592 SS630 SSE38 1232-70. 3310-75.