NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.

When there are large quantities of dust (solid foreign matter), install an air filter or main line filter to the inlet side of the mist separator. e. Install a regulator on the outlet side of the membrane air dryer. Dehumidification performance will be reduced if a regulator is a regulator is installed on the inlet side of the membrane dryer. f.

For low dew point air, use stainless steel or fluoropolymer piping. e. Installation of Differential Pressure Gauge Please attach by a customer.

Ignores excess current per unit for 100 msec. after inrush. Disable Does not ignore excess current Enable Ignores excess current.

suppressor With light/surge voltage suppressor Types S, Z Types R, U 38 or less 2 position single 33 or less 31 or less 30 or less 2 position double 28 or less 27 or less 56 or less 3 position 50 or less 50 or less Solenoid Specifications Grommet (G), (H), L type plug connector (L), M type plug connector (M), DIN terminal (D) Note 1) Electrical entry 24, 12, 6, 5, 3 DC Rated coil voltage V 100

The maximum pressure can be set as low as 10% and as high as 100% of the full span. For example, an ITV203 could be set to output 35 PSI at 0% input signal, and 43 PSI at 100% input signal (there must be at least 8 PSI separation).

ID20 ID30 ID40 ID60 Model 80 155 330 780 20 37 85 195 100 192 415 975 Recycled air flow rate Note) (L/min (ANR) Outlet air flow rate (L/min (ANR) Inlet air flow rate (L/min (ANR) Port size (Nominal size B) Weight (kg) 1 4 1 2 1 2 3 4 7 8.5 18.5 25 Supply dry air with a low dew point below 30C. Compact and lightweight without heater and electric control board.

Leave a space of 100 mm or more for maintenance on the valve guide side (opposite side from the knob). 3. When the product is installed between a solenoid valve and an actuator, select a backflow function type. Caution 1. Be sure to install a safety device to prevent damage or malfunction of the outlet side components when the output pressure exceeds the set pressure value. 2.

Leave a space of 100 mm or more for maintenance on the valve guide side (opposite side from the knob). 3. When the product is installed between a solenoid valve and an actuator, select a backflow function type. Caution 1. Be sure to install a safety device to prevent damage or malfunction of the outlet side components when the output pressure exceeds the set pressure value. 2.

(C) Installation features IDF IDU IDFA IDFB 0.05 to 1.0 (With auto drain: 0.15 to 1.0) 0.05 to 0.97 (With auto drain: 0.15 to 0.97) 2 to 50 Indoor ID Three phases 200 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source IDG 90 130 0.4 0.45 1.44 1.4 50 60

1 Air Tank Series AT Model/Standard Specifications AT11C AT22C AT37C AT55C AT75C AT125C AT150C (1) AT220C (1) AT6C Model Fluid Tank capacity (l) 400 500 700 Compressed air 1000 1500 2000 3000 100 200 Max. operating pressure (MPa) Port size 0.97 Rc 1/2 Rc 3/4 Rc 11/2 2B flange 3B flange 4B flange Set pressure for safety valve (MPa) 0.97 1.46 0 to 100 Proof pressure (Under water pressure) (

HAA15 HAA22 HAA37 HAA7 1000 Model Max. flow capacity (l/min (ANR)) (1) 5700 2200 3300 70 0.7 32 40 Compressed air 5 to 100 Rated performance Operating range Electrical specifications Inlet air temperature (C) Inlet air pressure (MPa) Ambient temperature (C) Outlet air temperature (C) Fluid Inlet air temperature (C) Inlet air pressure (MPa) Ambient temperature (C) Installation features 0.05

When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

Transmission speed 100 Mbps Transmission medium Standard Ethernet cable (CAT5) (100BASE-TX) Number of nodes connected (Up to 65,535 nodes.)

Model Max. rated flow Model Max. rated flow [L/min] [L/min] PFM510--1 10 (5) PFM510--2 10 (5) PFM525--1 25 (12.5) PFM525--2 25 (12.5) PFM550--1 50 (25) PFM550--2 50 (25) PFM511--1 100 (50) PFM511--2 100 (50) : ( ): Fluid: CO2 : ( ): Fluid: CO2 Flow adjustment needle revolution Flow characteristics (reference value) -23No.PF-OMJ0016-J Pressure loss (at 350 [kPa]) -24No.PF-OMJ0016-J Dimensions