Contents Bore size (mm) Set of left nos. @8, @9, #1, #2, #3, #4 @8 @9 #0 #1 #2 #3 #4 Cylinder tube gasket NBR REAL10-PS 10 REAL10-PS Guide shaft gasket NBR Set of left nos. @8, @9, #0, #1, #2, #3, #4 REAS15-PS 15 Wear ring A REAS15-PS 10: Not available Special resin Wear ring B Special resin Seal kit includes @8 to #4. Order the seal kit, based on each bore size.
9 @0 @1 @2 23 @4 Piston seal Set of left nos. !9, @0, @1, @2, @4 Rod seal A 23 is a non-replaceable part, so it is not included in the seal kit. Rod seal B NBR Gasket A Seal kits are sets consisting of items !9, @0, @1, @2 and @4 and can be ordered using the seal kit number for each cylinder bore size. Since the seal kit does not include a grease pack, order it separately.
Piston seal NBR CHSD100-PS Cylinder tube gasket NBR Seal kit consists of items @1 to @5 and @9, and can be ordered by using the seal kit number for each bore size. Holder gasket NBR 27 Valve seal NBR 28 @9 Valve holder gasket NBR Cushion seal 208
2.5 to 6 6 to 20 20 to 40 40 to 63 63 to 100 AS13l1F AS13l1F AS23l1F AS33l1F AS43l1F / 1 8, / 1 4 / 1 4, / 3 8 / 1 2 Elbow (Metal Body) M5 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS12l1 AS22l1 AS22l1 AS32l1 AS42l1 / 1 8 4.1-7 / 1 4 / 3 8 / 1 2 In-line 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS1001F AS2001F AS2051F AS3001F AS4001F 4.1-9 Dual Speed Controller 6 to 20 20 to 32 20
To Travel amount per 1 command pulse (P=1m) by actuator lead (L = 6mm) and pulley ratio (n1/n2 = 1/1) = 1 1048576 1 1000 Pn210 Pn20E 1 6 1/1 = 1048576 Pn210 Pn20E 6 1000 1 = 1048576 Pn210 Pn20E 6000 1 = 65536 Pn210 Pn20E 375 1 *1 For pulley ratio, refer to Lead of LECYU Operation Manual (Simplified Edition),section 4.4.1.
Contents J (1) Head side flange style (1) 20 25 Clevis integrated style CM2X20-PS D1 pc. Rod seal: CM2X25-PS 32 40 (1) Single clevis style CM2X32-PS (1) Double clevis style (3) Grease pack (10 g): 1 pc. -X CM2X40-PS (1) (2) Rod side trunnion style 2. Grease pack When maintenance requires only grease, use the following part numbers to order.
Give adequate confirmation, and then determine a model, just because the compatibility list shows the general case. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump
The warranty period of the product is 1 year in service or 1. The warranty period of the product is 1 year in service or 1.
Setting flow range 0.09 to 1.45 0.45 to 5.81 0.9 to 14.5 1.8 to 37.0 5 to 92 gal/min gal/min gal/min gal/min gal/min Min. setting/ display unit 0.01 gal/min 0.1 gal/min 1 gal/min Setting/display flow unit 9.9 gal 9 gal Accumulated flow Min. setting/ diplay unit 0.1 gal 1 gal Conversion of accumulated pulse 0.01 gal/pulse 0.05 gal/pulse 0.1 gal/pulse 0.5 gal/pulse 1 gal/pulse Temperature specification
pressure 0.1 0.3 MPa 2 x Rc 1/4, NPT 1/4 HAA HAW 0.1 MPa Max. flow rate line B Pressure drop MPa AT IN 0.01 IDF IDU 0.7 MPa 0.5 MPa IDF FS A 0.001 IDFA A B Model Connection Rc 1/4 NPT 1/4 Rc 1/4 NPT 1/4 Rc 1/4 NPT 1/4 SFA100-02 SFA101-02 SFA200-02 SFA201-02 SFA300-02 SFA301-02 46 76 IDFB 51 96 IDH 0.0001 1000 1 10 100 59 120 ID Flow rate L/min (ANR) IDG SFA20 SFA102, SFA202, SFA302 IDK 0.1
180 45 104 79 65 Rc 1 1/2, NPT 1 1/2, G 1 1/2 46 M6 x 1 9 ON OFF 75 220 55 114 89 75 Rc 2, NPT 2, G 2 56 M6 x 1 9 50msec PFA7H-(-M) 68 69 Analog output 1 to 5VDC 4 to 20mADC 5 20 Analog output [mA] Analog output [V] 1 4 Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l/min] Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l
0.024 0.008 0.016 V114 V114A V124 Note 1) V124A Note 1) Note 1) For both V124 and V124A, pressure from port 3 and exhaust from port 1.
Recommended Tightening Torque (Nm) Air Supply Connection thread 1/8 1/4 3/8 1/2 Caution 7 to 9 12 to 14 22 to 24 28 to 30 Torque 1. Use clean air. If chemicals, organic solvents, synthetic oil or corrosive gases are included in the compressed air, parts could be damaged or they can cause a malfunction. 2.
Model Specifications AN101-01 AN110-01 AN120-M3 AN120-M5 R R M3 M5 1 8 1 8 Port size (1) Noise reduction (dB (A)) Fluid Max. operating pressure (2) 13 18 16 21 Compressed air 1.0 MPa 5 to 150C (3) Ambient and fluid temperature Effective area (mm2) Weight (g) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Dimensions (mm) JIS Symbol Note 1) NPT thread for AN101 and AN110 is also available
Recommended Tightening Torque (Nm) Air Supply Connection thread 1/8 1/4 3/8 1/2 Caution 7 to 9 12 to 14 22 to 24 28 to 30 Torque 1. Use clean air. If chemicals, organic solvents, synthetic oil or corrosive gases are included in the compressed air, parts could be damaged or they can cause a malfunction. 2.
from the VY Valve. 02 14 2.0 3 03 38 3.3 body Ported Type 04 12 3.9 Terminal Designations are as follows: 04 12 7.2 5 06 34 8.9 1 = 24v Power Supply 2 = Control Signal 3 = Common Negative for both power and signal. 10 1 10 5% 2% + -2% 7 10 1 114 17 12 114 18 9 14 112 2 33 20 2 37 Courtesy of Steven Engineering, Inc. !
Temperature characteristics 0.5%F.S. max. (25 oC reference) 9.9 L 9 L Accumulated flow range 1 By 0.1 L By 0.5 L By 1 L Switch output NPN or PNP open collector output Max. load current 80 mA Max. applied voltage 28 VDC Internal voltage drop NPN: 1 V max. (at 80 mA load current) PNP: 1.5 V max.
1 set SYJA5240 1 set SYJ5000-21-1A 1 set 3 position closed center 3 position exhaust center (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 3 (R) 1 (P) 3 (R) The asterisk denotes the symbol for assembly.