Indication Item Setting and selection 1 A contact (normally open) Contact type B contact (normally closed) 1 Alternate Signal form (1) Input 1 Contact input signal 1 Momentary [Off] Disabled [External Switch] External switch signal Signal type [Run/Stop] 1 Run/stop signal [Run] 2 Run signal 1 A contact (normally open) Contact type B contact (normally closed) 1 Alternate Signal form (2) Input

(example: If the Pressure switch with output impedance of 1 k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5 (V) x 1 (M)/(1 (k) + 1 (M)) 4.995 (V), and there is an error of approximate 0.005 V). Output impedance Operation mode Either hysteresis mode or window comparator mode can be selected.

Hs D-G39/K39 D-A3 34 56 56 A A 36 49 Auto switch G 1/2 (applicable cable O.D. 6.8 to 11.5) Approx.

Qty. 1 2 3 4 PVC pipe Seal Body Sensor PVC pipe (25A) PVC pipe (30A) 1 1 CPVC ZS-40-U25 ZS-40-U30 1 FKM PPS PPS 25A retaining plate (M5 x 80 with two hexagonal socket head cap screws) ZS-40-U25-A 1 5 30A retaining plate (M5 x 65 with two hexagonal socket head cap screws) PF3W ZS-40-U30-A 1 Replacing the PVC pipe may cause accuracy to fluctuate by 1 to 2%. 3-Color Display Digital Flow Monitor

"HHH" is displayed. (1) Reset applied flow to a level within the set flow range. "LLL" is displayed. (1) Check if the flow exceeds the upper limit of the set flow range.

Setup communication cable part number (with A-miniB type USB cable): JX-CT-E PC 120.3 120.3 mm mm Electric actuator Setup communication cable 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 USB cable A-miniB type PC is prepared by the user. ..

least significant bit, and fill a 0 into the most significant bit position. 4 If the bit extracted as a result of 1 bit shift is 1, the result of 3) and the value ExOR of "A001h" are executed (Example 1).

Ht A B 20 Approx. Hs Auto switch D-F5/J59 D-F5NT D-F5W/J59W D-F5BA/F59F D-A5/A6 D-A59W Approx. Ht Approx. Ht A 33 B Approx. Hs G 1/2 (applicable cable O.D. 6.8 to 9.6) D-G39/K39 D-A3 56 34 B 36 A 49 Auto switch G 1/2 (applicable cable O.D. 6.8 to 9.6) Approx. Hs D-A44 56 B 36 Auto switch 49 A Approx.

(port P1 pressure: port 2 (A) pressure = 1:1) When the reduced pressure is supplied from 3 (R) to 2 (A), air will not be exhausted from 2 (A) to 1 (P) even when the pilot pressure (port P1) is larger than the port 2 (A) pressure.

Setup communication cable part number (with A-miniB type USB cable): JX-CT-E PC 120.3 120.3 mm mm Electric actuator 200 200 mm/s mm/s Setup communication cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 USB cable A-miniB type PC is prepared by the user. ..

No setting 1 4 2 5 7 2 5 3 2 2 3 5 3 1 MHZ2-16 No setting 3 2 4 1 MHZ2-20 MHZ2-25 MHZJ2-10 No setting No setting MHZJ2-16 No setting No setting 3 2 1 MHZJ2-20 MHZJ2-25 Note) "" in the table indicates a skip with no dimension.

MPa 0 to 28 MPa No code A Pressure gauge unit 3) 1) Only available with SL5502.

Pneumatic Circuit Manually Unlocking Caution Warning 1. A 3 position pressure center solenoid valve and regulator with check valve can be replaced with two 3 port normally open valves and a regulator with relief function. 1. Never operate the unlocking cam until safety has been confirmed.

(Part 1: General requirements) ISO 10218-1: Manipulating industrial robots Safety. etc. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

CFM x 10-2 1 CFM x 10-2 Accumulated Setting/Display flow range 0.0 to 9.0 0.0 to 9.9 0 to 9 0 to 9 ft3 x 10-1 ft3 x 10-1 ft3 x 10-1 ft3 x 10-1 flow Min. setting/display unit 0.1 ft3 x 10-1 0.1 ft3 x 10-1 1 ft3 x 10-1 1 ft3 x 10-1 Conversion of accumulated pulse 0.1 1 1 1 ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse : Flow rate in the specification is the value at standard

VQZ2000 (12.6) VQZ3000 (21.6) VFR2000 (16.2) VFR3000 (41.4) VFR4000 (67.0) 0.5 0.1 0.3 In-line type VFS1000 (9.0) VFS2000 (18.0) VFS3000 (36.0) VFS4000 (64.5) 2-B 5 AS221F (3.5) AS231F (3.5) AS2051F (4.5) AS220 (2.9) AS2000 (3.8) AS3001F (6.5) 1-A 1-B 1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2

Manifold material PFA Tubing size 1 2 ... Stations Orifice diameter 1/4 3/8 1/2 Valve type Symbol Type 4 8 10 P P Manifold A A N.C. Stations are counted from station 1 on the left side, with the A (OUT) ports in front. A Non-locking Locking A A (OUT) port LLH2A-03-SH 1 set 1 set Manifold base part no. LVH20A-S07 2 sets 2 sets Valve part no.

Jumping is a condition in which the cylinder operates without control at a speed that is higher than the control speed. Skip valve 1. When using a skip valve, the maximum allowable ratio between the high speed and the low speed is approximately 3:1.

(Part 1: General requirements) ISO 10218-1: Manipulating industrial robots Safety. etc. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

occurred. 1: A warning has occurred. 7 W 8 The value at reading is undefined.