Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: NPTF, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: NPTF, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: NPTF, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 200VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, FPM Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.2 Solenoid, Body Size: 25A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, FPM Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 100VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Cost effective and clean looking, series 25A-AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the 25A-AR series connects with other SMC air preparation equipment.
Cost effective and clean looking, series 25A-AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the 25A-AR series connects with other SMC air preparation equipment.
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, "PRESSURE SWITCH
Size/Valve Type: 6 (25A, N.C.), Body/Port/Orifice: L (Stainless Steel; Port 1;, Orifice 25), Voltage/Electrical Entry: M (24VDC, Conduit Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)
Size/Valve Type: 6 (25A, N.C.), Body/Port/Orifice: L (Stainless Steel; Port 1;, Orifice 25), Voltage/Electrical Entry: M (24VDC, Conduit Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)
(Note 1) According to this formula, multiply the following values by the piping length (□m) to get the piping resistance.
Approx. 0.0035 MPa/m for a port size 15A thermo-chiller (Note 2), approx. 0.0026 MPa/m for a port size 20A thermo-chiller (Note 2), and approx. 0.0022 MPa/m for a port size 25A thermo-chiller (Note 2). However, SMC does not design or install piping systems.
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: L (Light)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 4 (220VAC 50/60HZ), Lead Wire: C (Conduit)